X-ray phase-contrast imaging at 100 keV on a conventional source

被引:43
|
作者
Thuering, T. [1 ,2 ]
Abis, M. [1 ,2 ]
Wang, Z. [1 ]
David, C. [1 ]
Stampanoni, M. [1 ,2 ]
机构
[1] Paul Scherrer Inst, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
来源
SCIENTIFIC REPORTS | 2014年 / 4卷
关键词
COMPUTED-TOMOGRAPHY; GRATINGS;
D O I
10.1038/srep05198
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray grating interferometry is a promising imaging technique sensitive to attenuation, refraction and scattering of the radiation. Applications of this technique in the energy range between 80 and 150 keV pose severe technical challenges, and are still mostly unexplored. Phase-contrast X-ray imaging at such high energies is of relevant scientific and industrial interest, in particular for the investigation of strongly absorbing or thick materials as well as for medical imaging. Here we show the successful implementation of a Talbot-Lau interferometer operated at 100 keV using a conventional X-ray tube and a compact geometry, with a total length of 54 cm. We present the edge-on illumination of the gratings in order to overcome the current fabrication limits. Finally, the curved structures match the beam divergence and allow a large field of view on a short and efficient setup.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Contrast and resolution in direct Fresnel diffraction phase-contrast imaging with partially coherent x-ray source
    Han, SS
    Yu, H
    Cheng, J
    Gao, C
    Luo, ZL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3146 - 3151
  • [42] 10 keV X-ray phase-contrast microscopy for observing transparent specimens
    Kagoshima, Y
    Ibuki, T
    Yokoyama, Y
    Tsusaka, Y
    Matsui, J
    Takai, K
    Aino, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2001, 40 (11A): : L1190 - L1192
  • [43] Phase-space formulation for phase-contrast x-ray imaging
    Wu, XZ
    Liu, H
    APPLIED OPTICS, 2005, 44 (28) : 5847 - 5854
  • [44] Imaging renal structures by X-ray phase-contrast microtomography
    Wu, Jin
    Takeda, Tohoru
    Lwin, Thet Thet
    Momose, Atsushi
    Sunaguchi, Naoki
    Fukami, Tadanori
    Yuasa, Tetsuya
    Akatsuka, Takao
    KIDNEY INTERNATIONAL, 2009, 75 (09) : 945 - 951
  • [45] Phase-contrast x-ray imaging for nondestructive evaluation of materials
    Zoofan, B.
    Kim, J. -Y.
    Rokhlin, S. I.
    Frankel, G. S.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (01)
  • [46] Image Fusion in X-Ray Differential Phase-Contrast Imaging
    Haas, W.
    Polyanskaya, M.
    Bayer, F.
    Goedel, K.
    Hofmann, H.
    Rieger, J.
    Ritter, A.
    Weber, T.
    Wucherer, L.
    Durst, J.
    Michel, T.
    Anton, G.
    Hornegger, J.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [47] Phase retrieval in X-ray phase-contrast imaging suitable for tomography
    Burvall, Anna
    Lundstrom, Ulf
    Takman, Per A. C.
    Larsson, Daniel H.
    Hertz, Hans M.
    OPTICS EXPRESS, 2011, 19 (11): : 10359 - 10376
  • [48] Implicit tracking approach for X-ray phase-contrast imaging with a random mask and a conventional system
    Quenot, Laurene
    Rouge-Labriet, Helene
    Bohic, Sylvain
    Berujon, Sebastien
    Brun, Emmanuel
    OPTICA, 2021, 8 (11): : 1412 - 1415
  • [49] Vessel imaging by interferometric phase-contrast x-ray technique
    Takeda, T
    Momose, A
    Wu, J
    Yu, QW
    Zeniya, T
    Thet-Thet-Lwin
    Yoneyama, A
    Itai, Y
    CIRCULATION, 2002, 105 (14) : 1708 - 1712
  • [50] Phase-contrast and fluorescent X-ray imaging for biomedical researches
    Takeda, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 38 - 46