Combining immunofluorescence with immunoblot assay improves the specificity of autoantibody testing for myositis

被引:28
|
作者
Infantino, M. [1 ]
Tampoia, M. [2 ]
Fabris, M. [3 ]
Alessio, M. G. [4 ]
Previtali, G. [4 ]
Pesce, G. [5 ]
Deleonardi, G. [6 ]
Porcelli, B. [7 ]
Musso, M. [8 ]
Grossi, V. [1 ]
Benucci, M. [9 ]
Manfredi, M. [1 ]
Bizzaro, N. [10 ]
机构
[1] Azienda USL Toscana Ctr, Osped S Giovanni di Dio, Lab Immunol & Allergol, Florence, Italy
[2] Policlin Bari, Azienda Osped Univ, Lab Patol Clin, Bari, Italy
[3] Azienda Sanit Univ Integrata Udine, SOC Ist Patol Clin, Udine, Italy
[4] Lab Anal Chim Clin ASST Papa Giovanni XXIII, Bergamo, Italy
[5] DiMI Univ Genova, Lab Autoimmunol & Coordinamento Con Clin, Genoa, Italy
[6] AUSL Bologna, Lab Unico Metropolitano, Bologna, Italy
[7] Univ Siena, Dipartimento Biotecnol Med, Siena, Italy
[8] Lab Anal ASO S Croce & Carle, Cuneo, Italy
[9] Azienda USL Toscana Ctr, Osped S Giovanni di Dio, Reumatol, Florence, Italy
[10] Osped San Antonio, Lab Patol Clin, Tolmezzo, Italy
关键词
myositis; MSA; immunofluorescence; ANA pattern; immunoblot; algorithm; IIM; combination; specificity; antibody; IDIOPATHIC INFLAMMATORY MYOPATHIES; NEGATIVE ANTINUCLEAR ANTIBODY; FEATURES; BLOT;
D O I
10.1093/rheumatology/key451
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Immunoblot (IB) methods are widely used to detect myositis-specific autoantibodies (MSAs); however, false-positive results are common. In this study, we aimed to determine whether associating the anti-nuclear antibody (ANA) IIF pattern may help to improve the specificity of MSA detection by IB in patients with idiopathic inflammatory myositis (IIM). Methods Serum samples from 104 patients presenting with muscle weakness/myalgia and positive to at least one MSA by IB (MYOS12 Diver and MIOS7 Diver, D-tek) were tested for ANAs on HEp-2000 cells (Immuno Concepts). The chi-square test was used to analyse the concordance of the MSA result and its corresponding pattern by ANA testing between patients with and without IIM. Results Eighty-three of the 104 patients had a diagnosis of definite IIM, while in 21 cases, patients were affected by other autoimmune diseases or various non-systemic diseases. Forty nine of 83 (59%) patients in the IIM group and 4/21 (19%) in the non-IIM group showed a concordance between ANA pattern and MSAs by IB (P < 0.001). MSA monopositivity was significantly associated with IIM (91.6%) compared with 61.9% in the non-IIM group (P = 0.0005). Conclusions Considering both the MSA result and its corresponding pattern by ANA testing may help to improve the specificity of MSA detection by IB and to confirm the diagnosis of MSA-associated IIM. The monopositivity of MSAs is an important additional tool to validate IB results.
引用
收藏
页码:1239 / 1244
页数:6
相关论文
共 50 条
  • [21] Comment on: The reliability of immunoassays to detect autoantibodies in patients with myositis is dependent on autoantibody specificity: reply
    Tansley, Sarah L.
    McHugh, Neil J.
    RHEUMATOLOGY, 2020, 59 (08) : 2177 - 2178
  • [22] The interdependency of autoantibody assay in testing for systemic lupus erythematosus
    Swaak, Tom J.
    Nieuwenhuys, Ed J.
    Nossent, Hans C.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2006, 35 : 55 - 55
  • [23] Preheating of urine improves the specificity of urinary cryptococcal antigen testing using the lateral flow assay
    Brito-Santos, Fabio
    Ferreira, Marcela de Faria
    Trilles, Luciana
    Muniz, Mauro de Medeiros
    Veloso dos Santos, Valdilea Goncalves
    Carvalho-Costa, Filipe Anibal
    Meyer, Wieland
    Wanke, Bodo
    Lazera, Marcia dos Santos
    PLOS NEGLECTED TROPICAL DISEASES, 2017, 11 (05):
  • [24] SENSITIVITY AND SPECIFICITY OF ACETYLCHOLINE RECEPTOR AUTOANTIBODY TESTING FOR MYASTHENIA GRAVIS
    Paul, Pritikanta
    Bi, Hongyan
    Shelly, Shahar
    Basal, Eati
    Dubey, Divyanshu
    McKeon, Andrew
    Pittock, Sean
    Mills, John
    Klein, Christopher
    MUSCLE & NERVE, 2019, 60 : S120 - S120
  • [25] Murine High Specificity/Sensitivity Competitive Europium Insulin Autoantibody Assay
    Babaya, Naru
    Liu, Edwin
    Miao, DongMei
    Li, Marcella
    Yu, Liping
    Eisenbarth, George S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (04) : 227 - 233
  • [26] INVESTIGATING THE SENSITIVITY AND SPECIFICITY OF THE MYOSITIS PROFILE-4 EUROLINE ASSAY
    Ventin-Rodriguez, Clara
    Lilleker, James B.
    Elkhalifa, Shuayb
    Chinoy, Hector
    RHEUMATOLOGY, 2019, 58 : 133 - 133
  • [27] RECOMBINANT IMMUNOBLOT IN THE SERODIAGNOSIS OF LYME BORRELIOSIS - COMPARISON WITH INDIRECT IMMUNOFLUORESCENCE AND ENZYME-LINKED-IMMUNOSORBENT-ASSAY
    WILSKE, B
    FINGERLE, V
    HERZER, P
    HOFMANN, A
    LEHNERT, G
    PETERS, H
    PFISTER, HW
    PREACMURSIC, V
    SOUTSCHEK, E
    WEBER, K
    MEDICAL MICROBIOLOGY AND IMMUNOLOGY, 1993, 182 (05) : 255 - 270
  • [28] AN ANA SCREENING ASSAY (ELIA® CTD SCREEN) CONTAINING MULTIPLE ANTIGENS INCREASES THE SENSITIVITY AND SPECIFICITY OF ANA TESTING BY INDIRECT IMMUNOFLUORESCENCE
    Steiner, G.
    Perkmann, T.
    Horn, T.
    Kiener, H. P.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1414 - 1414
  • [29] THE SENSITIVITY AND SPECIFICITY OF DIRECT IMMUNOFLUORESCENCE TESTING IN DISORDERS OF MUCOUS-MEMBRANES
    HELANDER, SD
    ROGERS, RS
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1994, 30 (01) : 65 - 75
  • [30] Comparative sensitivity of indirect immunofluorescence to immunoblot assay for the detection of circulating antibodies to bullous pemphigoid antigens 1 and 2
    Ghoshestani, R
    Kanitakis, J
    Nicolas, JF
    Cozzani, E
    Claudy, A
    BRITISH JOURNAL OF DERMATOLOGY, 1996, 135 (01) : 74 - 79