New methodology to evaluate the performance of ring resonators using optical low-coherence reflectometry

被引:11
|
作者
Gottesman, Y
Rao, EVK
Rabus, DG
机构
[1] CNRS, LPN, F-91460 Marcoussis, France
[2] Heinrich Hertz Inst Nachrichtentech Berlin GmbH, D-10587 Berlin, Germany
关键词
filter analysis; integrated optics; interferograms and reflectograms; optical low-coherence reflectometry (OLCR); racetrack-shaped resonators; ring design parameters; ring resonators; transmission and reflection modes; wavelength-division multiplexing (WDM);
D O I
10.1109/JLT.2004.829216
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the efficient implementation of optical low-coherence reflectometry (OLCR) measurements to evaluate the performance of InP-based high-index contrast ring resonators. Using examples of racetrack ring resonators, this paper shows here for the first time that all characteristic parameters relevant to resonator design (coupling coefficient re, propagation losses a, and optical cavity length L), and ultimately its performance, can be extracted in a straightforward manner. This is accomplished by introducing a new methodology that implicates OLCR measurements in transmission and also reflection modes as an alternative approach, in comparison with conventional spectral analysis, to extract resonator design parameters.
引用
收藏
页码:1566 / 1572
页数:7
相关论文
共 50 条
  • [1] MULTIPLEXED SENSING USING OPTICAL LOW-COHERENCE REFLECTOMETRY
    SORIN, WV
    BANEY, DM
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (08) : 917 - 919
  • [2] Multilayer optical storage using low-coherence reflectometry
    Massachusetts Inst of Technology, Lexington, United States
    Conf Proc Laser Electr Optic Soc Annu Meet, (101-102):
  • [3] Noise in optical low-coherence reflectometry
    Takada, K
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1998, 34 (07) : 1098 - 1108
  • [4] Characterisation of photonic devices using optical low-coherence reflectometry
    Palavicini, C.
    Jaouen, Y.
    Gallion, P.
    REVISTA MEXICANA DE FISICA, 2006, 52 (04) : 379 - 386
  • [5] Multilayer optical storage by low-coherence reflectometry
    Chinn, SR
    Swanson, EA
    OPTICS LETTERS, 1996, 21 (12) : 899 - 901
  • [6] Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry
    Guler, Emre
    Kulak, Ali Ender
    Totan, Yuksel
    Yuvarlak, Armagan
    Hepsen, Ibrahim Feyzi
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (05): : 336 - 341
  • [7] Analysis of distributed feedback lasers using optical low-coherence reflectometry
    Wiedmann, U
    Gallion, P
    Jaouen, Y
    Chabran, C
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1998, 16 (05) : 864 - 869
  • [8] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1165 - 1172
  • [9] Evaluation of the performance of dual-order mode couplers using optical low-coherence reflectometry
    Piot, D
    Gottesman, Y
    Rao, EVK
    Dagens, B
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2000, 12 (12) : 1659 - 1661
  • [10] DS-OCDMA encoder/decoder performance analysis using optical low-coherence reflectometry
    Fsaifes, Ihsan
    Lepers, Catherine
    Obaton, Anne-Francoise
    Gallion, Philippe
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2006, 24 (08) : 3121 - 3128