Development of superconducting tunnel junction detectors for high-resolution X-ray spectroscopy

被引:23
|
作者
Angloher, G
Beckhoff, B
Bühler, M
von Feilitzsch, F
Hertrich, T
Hettl, P
Höhne, J
Huber, M
Jochum, J
Mössbauer, RL
Schnagl, J
Scholze, F
Ulm, G
机构
[1] Tech Univ Munich, Phys Dept E15, D-85747 Garching, Germany
[2] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[3] CSP Cryogen Spectrometers GMBH, D-85737 Ismaning, Germany
关键词
D O I
10.1016/S0168-9002(99)01362-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The energy resolution of aluminum superconducting tunnel junctions (Al-STJs) has been improved by the introduction of a metallic buffer layer underneath the junction. When irradiated by 5.9 keV X-rays, a resolution of 12 eV (FWHM) was achieved for a junction size of 100 x 100 mu m(2). A mobile refrigerator system allowed to characterize these devices at the PTB-beamlines of the electron storage rings Bessy I and Bessy II. They showed linear energy response in the range between 200 eV and 6.5 keV and a strong increase in reduced energy events if irradiated at X-ray energies below the Al absorption edge at 1.56 keV. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 50 条
  • [21] Soft X-ray response of a 36 pixel superconducting tunnel junction array for high-resolution X-ray astronomy.
    Rando, N
    Verhoeve, P
    Kraft, S
    den Hartog, R
    Peacock, A
    Goldie, DJ
    Hart, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 247 - 254
  • [22] Radiation effects in superconducting-tunnel-junction X-ray detectors
    Ohkubo, M
    Sakamoto, I
    Miura, T
    Hayashi, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 343 - 346
  • [23] Temporal shape of the signals of superconducting tunnel junction X-ray detectors
    Andrianov V.A.
    Gorkov V.P.
    Bull. Russ. Acad. Sci. Phys., 4 (554-559): : 554 - 559
  • [24] Radiation effects in superconducting-tunnel-junction X-ray detectors
    Electrotechnical Lab, Ibaraki, Japan
    Nucl Instrum Methods Phys Res Sect A, 2-3 (343-346):
  • [25] Double peak phenomenon in superconducting tunnel junction x-ray detectors
    Ohkubo, M
    Fukuda, D
    Sakamoto, I
    Hayashi, N
    Martin, J
    Panteleit, F
    Huebener, RP
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (01) : 595 - 599
  • [26] DEVELOPMENT OF MICROCALORIMETERS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    KELLEY, RL
    MOSELEY, SH
    STAHLE, CK
    SZYMKOWIAK, AE
    JUDA, M
    MCCAMMON, D
    ZHANG, J
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1993, 93 (3-4) : 225 - 230
  • [27] Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS
    Friedrich, Stephan
    Drury, Owen B.
    Hall, John
    Cantor, Robin
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 101 - +
  • [28] HIGH-RESOLUTION X-RAY SPECTROSCOPY
    NAGEL, DJ
    KNUDSON, AR
    BURKHALT.PG
    DUNNING, KL
    REPORT OF NRL PROGRESS, 1971, (JUN): : 15 - &
  • [29] Resolution degradation in X-ray detectors based on superconducting tunnel junctions
    den Hartog, R
    Verhoeve, P
    Peacock, A
    Poelaert, A
    Rando, N
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4495 - 4498
  • [30] Line-splitting in high-resolution superconducting tunnel junction EUV detectors
    Friedrich, S
    Hiller, LJ
    Cunningham, MF
    Labov, SE
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 836 - 839