DC-Surge Arresters for Railway Applications

被引:0
|
作者
Hippler, Christoph [1 ]
机构
[1] Tridelta Meidensha GmbH, Hermsdorf, Germany
关键词
Metal-oxide arrester; MO arrester; surge arrester; railway application; traction system; direct voltage; superimposed voltage; composite voltage; mixed voltage; electrical conductivity; power loss density;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The limitation of electrical overvoltages to protect cost intensive and high-maintenance railway application can be realised reliably by metal-oxide surge arresters (MO arrester). With the help of MO arresters lightning and surge overvoltages can limit. The operating voltage can consist of a variety of waveforms and sometimes places very high demands on the electrical equipment, like the MO arresters. With the help of experimental investigations on various MO varistors at different waveforms of operating voltages the electrical conductivity and the occurring power loss density of the MO varistors were determined and evaluated. Further, guidance is given for the dimension and selection of MO arresters for different railway applications.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [21] Diagnostic of silicon carbide surge arresters of substation
    Kanashiro, Arnaldo G.
    Zanotti Jr., Milton
    Obase, Paulo F.
    Bacega, Wilson R.
    WSEAS Transactions on Systems, 2009, 8 (12): : 1284 - 1293
  • [22] MODELING OF METAL-OXIDE SURGE ARRESTERS
    JONES, RA
    CLIFTON, PR
    GROTZ, G
    LAT, M
    LEMBO, F
    MELVOLD, DJ
    NIGOL, D
    SKIVTAS, JP
    SWEETANA, A
    GOODWIN, DF
    KOEPFINGER, JL
    LENK, DW
    LATOUR, Y
    LESKOVICH, RT
    MUSA, Y
    ADINZH, J
    STUMP, K
    TAYLOR, ER
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 302 - 309
  • [23] Simulation of Metal Oxide Surge Arresters Behavior
    Christodoulou, Christos A.
    Assimakopoulou, Fani A.
    Gonos, Ioannis F.
    Stathopulos, Ioannis A.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 1862 - 1866
  • [24] ZnO surge arresters diagnosis using microcontroller
    Lira, Jose G. A.
    Macedo, Euler C. T.
    Costa, Edson G.
    Freire, Raimundo C. S.
    Luciano, Benedito A.
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 835 - 840
  • [25] Quality Assessment of Low Voltage Surge Arresters
    Litzbarski, Leszek S. S.
    Olesz, Marek
    Wojtas, Stanislaw
    Winiarski, Michal J. J.
    Klimczuk, Tomasz
    Glowinski, Hubert
    Andrzejewski, Bartlomiej
    IEEE ACCESS, 2022, 10 : 129313 - 129321
  • [26] High frequency and impulse earthing for surge arresters
    Griffiths, H.
    Van De Linde, F.
    Uliah, N.
    Haddad, A.
    Harid, N.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1454 - 1459
  • [27] Three Dimensional Analysis of ZnO Surge Arresters
    Vahidi, B.
    Shariatinasab, R.
    Moghani, J. Sh.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (04): : 642 - 648
  • [28] Condition Monitoring of Post Insulators and Surge Arresters
    Vitols, Arnold P.
    Stead, John
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 551 - +
  • [29] SWITCHING SURGE INSULATION COORDINATION - LIGHTNING ARRESTERS
    CARRARA, G
    DELLERA, L
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (01): : 154 - &
  • [30] Radioactive reliability of gas filled surge arresters
    Loncar, B
    Osmokrovic, P
    Stankovic, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1725 - 1731