X-ray mammogram registration: A novel validation method

被引:0
|
作者
Hipwell, John H. [1 ]
Tanner, Christine [1 ]
Crum, William R. [1 ]
Hawkes, David J. [1 ]
机构
[1] UCL, Ctr Med Image Comp, London WC1E 6BT, England
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Establishing spatial correspondence between features visible in x-ray mammograms obtained at different times has great potential to aid assessment of change in the breast and facilitate its quantification. The literature contains numerous non-rigid registration algorithms developed for this purpose, but quantitative estimation of registration accuracy is limited. We describe a novel validation method which simulates plausible mammographic compressions of the breast using all MRI derived finite element model. Known 3D displacements are projected into 2D and test images simulated from these same compressed MR volumes. In this way we call generate convincing images with known 2D displacements with which to validate a registration algorithm. We illustrate this approach by computing the accuracy for a non-rigid registration algorithm applied to mammograms simulated from three patient MR datasets.
引用
下载
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [31] A novel method for the synthesis of X-ray imaging degradable polymers
    Fan, You Kun
    Feng, Shao Min
    Liu, Xi Liang
    Li, Kai Qi
    Bao, Yi Hong
    Bao, Yi Liang
    Chen, Long
    Chen, Dong Liang
    Xiong, Cheng Dong
    EUROPEAN POLYMER JOURNAL, 2022, 180
  • [32] A novel method for the synthesis of X-ray imaging degradable polymers
    Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Sichuan, Chengdu
    610041, China
    不详
    100039, China
    不详
    322000, China
    Eur Polym J, 2022,
  • [33] A novel method for producing x-ray test objects and phantoms
    Theodorakou, C
    Horrocks, JA
    Marshall, NW
    Speller, RD
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08): : 1423 - 1438
  • [34] Registration method for interval change between two chest X-ray images with rotation
    Shimizu, A
    Matsuo, Y
    Kobatake, H
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 917 - 922
  • [35] Parametric X-ray radiation as a novel source for X-ray imaging
    Takahashi, Yumiko
    Hayakawa, Yasushi
    Kuwada, Takao
    Tanaka, Toshinari
    Sakae, Toshiro
    Nakao, Keisuke
    Nogami, Kyoko
    Imagaki, Manabu
    Hayakawa, Ken
    Sato, Isamu
    X-RAY SPECTROMETRY, 2012, 41 (04) : 210 - 215
  • [36] A novel x-ray intensifier
    Yu, CY
    Liu, TB
    Wu, LL
    Chang, BK
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 141 - 145
  • [37] Bayesian Maximum Entropy Based Algorithm for Digital X-ray Mammogram Processing
    Mutihac, Radu
    ALGORITHMS, 2009, 2 (02) : 850 - 878
  • [38] Multidimensional registration of X-ray image and CT image
    Zhang, H
    Haigron, P
    Shu, HZ
    Luo, LM
    MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 : 717 - 724
  • [39] Projection registration of X-ray image and CT image
    Zhang, Hui
    Luo, Limin
    Shu, Huazhong
    Li, Songyi
    Haigron, Pascal
    Journal of Southeast University (English Edition), 2003, 19 (01) : 26 - 30
  • [40] A portable instrument for the measurement and registration of X-ray intensity
    Sievert, RM
    ACTA RADIOLOGICA, 1925, 4 (02) : 129 - 132