Iterative reconstruction of SPECT data with adaptive regularization

被引:0
|
作者
Riddell, C [1 ]
Buvat, I [1 ]
Savi, A [1 ]
Gilardi, MC [1 ]
Fazio, F [1 ]
机构
[1] GE Co, Med Syst, Buc, France
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A least-square reconstruction criterion is proposed for simultaneously estimating a SPECT (Single Photon Emission Computed Tomography) emission distribution corrected for attenuation together with its degree of regularization. Only a regularization trend has to be defined and tuned once for all on a reference study. Given this regularization trend, the precise regularization weight, which is usually fixed a priori, is automatically computed for each data set to adapt to the noise content of the data. We demonstrate that this adaptive process yields better results when the noise conditions change than when the regularization weight is kept constant. This adaptation is illustrated on simulated cardiac data for noise variations due to changes in the acquisition duration, in the background intensity and in the attenuation map.
引用
收藏
页码:1859 / 1863
页数:5
相关论文
共 50 条
  • [31] Noise histogram regularization for iterative image reconstruction algorithms
    Thurman, Samuel T.
    Fienup, James R.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (03) : 608 - 617
  • [32] Sparse regularization in MRI iterative reconstruction using GPUs
    Zhuo, Yue
    Sutton, Bradley
    Wu, Xiao-Long
    Haldar, Justin
    Hwu, Wen-mei
    Liang, Zhi-pei
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 578 - 582
  • [33] Non-Linear Iterative Regularization Algorithm for Neural Activity Reconstruction from EEG Data
    Felipe Soler, Andres
    Giraldo, Eduardo
    2018 IEEE ANDESCON, 2018,
  • [34] Practical iterative reconstruction methods for quantitative cardiac SPECT image reconstruction
    Tsui, Benjamin M.W.
    Zhao, Xide
    IEEE Transactions on Nuclear Science, 1994, 41 (1 pt 2) : 325 - 330
  • [35] Variable scale reconstruction with nonuniform attenuation for SPECT iterative reconstruction.
    Riddell, C
    Buvat, I
    N'Guyen, T
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 57P - 58P
  • [36] Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT
    Sibille, Louis
    Chambert, Benjamin
    Alonso, Sandrine
    Barrau, Corinne
    D'Estanque, Emmanuel
    Al Tabaa, Yassine
    Collombier, Laurent
    Demattei, Christophe
    Kotzki, Pierre-Olivier
    Boudousq, Vincent
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1091 - 1095
  • [37] REDUCTION OF BLADDER ARTIFACT IN SPECT BY AN ITERATIVE RECONSTRUCTION ALGORITHM
    REULAND, P
    KAISER, W
    MULLERSCHAUENBURG, W
    FEINE, U
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1991, 22 (01): : 23 - 24
  • [38] Recent developments in iterative image reconstruction for PET and SPECT
    Leahy, R
    Byrne, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) : 257 - 260
  • [39] CLINICAL EVALUATION OF VENDOR ITERATIVE RECONSTRUCTION IN BRAIN SPECT
    Barnden, L.
    Casse, R.
    INTERNAL MEDICINE JOURNAL, 2014, 44 : 10 - 10
  • [40] Generic Iterative Reconstruction of Multi-Pinhole SPECT
    Ryder, William J.
    Brennan, Matthew P.
    Sinusas, Albert J.
    Liu, Yi-Hwa
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913