A highly sensitive biodegradable pressure sensor based on nanofibrous dielectric

被引:56
|
作者
Khalid, Muhammad Asad Ullah [1 ]
Ali, Muhsin [1 ]
Soomro, Afaque Manzoor [1 ]
Kim, Soo Wan [1 ]
Kim, Hyun Bum [1 ]
Lee, Byung-Gul [2 ]
Choi, Kyung Hyun [1 ]
机构
[1] Jeju Natl Univ, Dept Mechatron Engn, Jeju, South Korea
[2] Jeju Natl Univ, Dept Civil Engn, Jeju, South Korea
关键词
Biodegradable; Piezo-capacitive; PLGA-PCL; Electrospinning; Nanofibers; PIEZORESISTIVE SENSOR; ELECTRONICS; NANOWIRES; NETWORK; TACTILE;
D O I
10.1016/j.sna.2019.05.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High performance biodegradable electronic devices are becoming popular due to their enormous applications as biomedical implants or short term communication devices. They are biocompatible and eco-friendly. For example wearable or implantable biodegradable pressure sensors are very useful for cardiovascular or blood flow monitoring. But unfortunately very few previous researches have focused on developing biodegradable pressure sensors. Here we propose a composite of Polylactic-co-glycolic acid (PLGA) and Polycaprolactone (PCL) for biodegradable piezo-capacitive pressure sensor fabrication for low pressure measurement in tactile ranges of (0 < P < 5 kPa). An electrospun PLGA-PCL composite membrane has been used as elastomeric dielectric sandwiched between two biodegradable iron-zinc (Fe-Zn) bilayer electrodes, deposited on degradable Polyvinyl alcohol (PVA) substrate using electron beam deposition, and encapsulated in PLGA thin films for device fabrication. PLGA-PCL nanofibrous dielectric membrane is highly compressible and porous having tunable mechanical as well as dielectric properties and has been reported first ever for biodegradable pressure sensor application. The sensitivity of the sensor was found to be 0.863 +/- 0.025 kPa(-1) in the low pressure region (0 < P <= 1.86 kPa) which is quite high as compared to previous literature on biodegradable sensors so far while it adapted to a value of 0.062 +/- 0.005 kPa(-1) for high pressure region (1.86 kPa < P <= 4.6 kPa). The lowest detected value was 1.24 Pa (at 10mgf). Sensor showed good average response and recovery times of 251 ms and 170 ms respectively. In vitro degradation studies of the sensor were performed in PBS solution and sensor lost 60% of its initial weight during first two weeks of degradation and continued to degrade even after that. After one week of incubation sensor showed a 19.5% decrease in low pressure measurement range while there was no significant difference in upper detection range. It has been used to measure the arterial pulse wave on wrist and a 4 x 4 pressure sensor array was made to demonstrate its use in mapping different pressure points. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 50 条
  • [21] A Highly Sensitive Flexible Capacitive Pressure Sensor with Micro-array Dielectric Layer
    Shuai, Xingtian
    Zhu, Pengli
    Liang, Xianwen
    Hu, Yougen
    Zhang, Yu
    Guo, Qian
    Su, Haibo
    Sun, Rong
    Wong, Chingping
    [J]. 2016 17TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY (ICEPT), 2016, : 289 - 294
  • [22] A flexible and highly sensitive pressure sensor based on elastic carbon foam
    Liu, Weijie
    Liu, Nishuang
    Yue, Yang
    Rao, Jiangyu
    Luo, Cheng
    Zhang, Hang
    Yang, Congxing
    Su, Jun
    Liu, Zhitian
    Gao, Yihua
    [J]. JOURNAL OF MATERIALS CHEMISTRY C, 2018, 6 (06) : 1451 - 1458
  • [23] Highly sensitive sensor based on W-lightguides for pressure measurements
    Rzhavin, YI
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION III, 2003, 5144 : 796 - 800
  • [24] Highly sensitive seesaw capacitive pressure sensor based on SOI wafer
    Yang, C. C.
    Zhao, Q.
    Gao, C. C.
    Liu, G. D.
    Zhang, Y. X.
    Cui, W. P.
    Hao, Y. L.
    [J]. ELECTRONICS LETTERS, 2014, 50 (05) : 376 - +
  • [25] Highly sensitive sensor based on w-lightguides for pressure measurements
    Rzhavin, YI
    [J]. WAVE OPTICS AND PHOTONIC DEVICES FOR OPTICAL INFORMATION PROCESSING II, 2003, 5181 : 203 - 207
  • [26] Highly Sensitive and Breathability Flexible Piezoresistive Pressure Sensor Based on Xylon
    Qin, Yuxiang
    Gao, Bo
    Zhou, Chuan
    [J]. ADVANCED MATERIALS TECHNOLOGIES, 2024, 9 (11)
  • [27] Highly-sensitive pressure sensor based on W-lighguides
    Yu. I. Rzhavin
    [J]. Measurement Techniques, 1999, 42 : 883 - 887
  • [28] Highly Sensitive, Breathable, and Flexible Pressure Sensor Based on Electrospun Membrane with Assistance of AgNW/TPU as Composite Dielectric Layer
    Wang, Jie
    Lou, Yaoyuan
    Wang, Bin
    Sun, Qing
    Zhou, Mingwei
    Li, Xiuyan
    [J]. SENSORS, 2020, 20 (09)
  • [29] A highly sensitive and flexible capacitive pressure sensor based on an ionic hydrogel dielectric layer with a lateral-bending microstructure
    Qiao, Haidi
    Liu, Xia
    Zhang, Xingyu
    Zhang, Jiayue
    Yin, Mingjie
    Yang, Qingsheng
    [J]. JOURNAL OF MATERIALS CHEMISTRY C, 2024, 12 (34) : 13485 - 13494
  • [30] Highly Sensitive Terahertz Dielectric Sensor for Liquid Crystal
    Li, Xianping
    Zheng, Guanghong
    Zhang, Guozhen
    Yang, Jun
    Hu, Minggang
    Li, Jian
    Li, Ying
    Lu, Hongbo
    Yin, Zhiping
    [J]. SYMMETRY-BASEL, 2022, 14 (09):