Value and limitations of the Continuous Glucose Monitoring System in the management of type 1 diabetes

被引:27
|
作者
Melki, V [1 ]
Ayon, F [1 ]
Fernandez, M [1 ]
Hanaire-Broutin, H [1 ]
机构
[1] Hop Rangueil, Serv Diabetol, F-31059 Toulouse 9, France
关键词
type; 1; diabetes; CGMS; glucose sensor; hypoglycaemia;
D O I
10.1016/S1262-3636(07)70258-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The CGMS (Continuous Glucose Monitoring System) is a portable device allowing continuous measuring of glucose. It provides recordings of at least 72 h, during which 288 measures/day are performed. Results are visualised in the form of a set of curves, illustrating the variations in blood glucose levels over time. The quality of the records has often been questioned by several authors. Some of the system's physiologically related limitations can be explained by the less than perfect coincidence of variations in glucose levels observed in the interstitial tissue, where CGMS measurings are done, and in the blood, where calibrations are performed. Other limitations, such as defects in accuracy or in reproducibility of tracings or premature curtailments of recordings, are due to technical weaknesses which were considerably improved during the past few years, particularly with regard to the quality of the electrodes providing a more stable signal over time. In clinical practice, CGMS is a tool for investigating the glycaemic patterns of diabetic patients in conjonction with SMBG. It allows the identification of overlooked hyper- or hypoglycaemia. Generally well accepted, it is a usefull tool to analyse the nocturnal period, or any situation where glucose checks are rare. The visual nature of its results provides a facilitating support in the discussion between the patient and the care-provider during consultations or educational sessions. CGMS utilisation was proposed for guiding treatment adjustment. At present, it is still difficult to state with certainty that this tool allows effective improvement in the metabolic control of patients with type 1 diabetes, in view of the paucity of controlled studies showing an impact on HbA(1c) values or on the frequency of hypoglycaemia, even if such a tendency emerges from most non-controlled intervention trials.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [31] Continuous glucose monitoring in adult patients with type 1 diabetes
    Heinemann, L.
    Siegmund, T.
    [J]. DIABETOLOGE, 2013, 9 (08): : 647 - 654
  • [32] Glucose Variations During Driving in People With Type 1 Diabetes Using a Continuous Glucose Monitoring System
    Schmied, Laurent Silvan
    Zulewski, Henryk
    [J]. DIABETES CARE, 2019, 42 (07) : 1340 - 1343
  • [33] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Sousa, Carolina
    Neves, Joao Sergio
    Dias, Claudia Camila
    Sampaio, Rute
    [J]. ENDOCRINE, 2023, 79 (03) : 477 - 483
  • [34] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Carolina Sousa
    João Sérgio Neves
    Cláudia Camila Dias
    Rute Sampaio
    [J]. Endocrine, 2023, 79 : 477 - 483
  • [35] Value of Capillary Glucose Profiles in Assessing Risk of Nocturnal Hypoglycemia in Type 1 Diabetes Based on Continuous Glucose Monitoring
    Ling, Qing
    Lu, Jing
    Li, Xiang
    Qiao, Chengcheng
    Zhu, Dalong
    Bi, Yan
    [J]. DIABETES THERAPY, 2020, 11 (04) : 915 - 925
  • [36] Value of Capillary Glucose Profiles in Assessing Risk of Nocturnal Hypoglycemia in Type 1 Diabetes Based on Continuous Glucose Monitoring
    Qing Ling
    Jing Lu
    Xiang Li
    Chengcheng Qiao
    Dalong Zhu
    Yan Bi
    [J]. Diabetes Therapy, 2020, 11 : 915 - 925
  • [37] Caregivers of Children with Type 1 Diabetes Value Real-Time Functions of Continuous Glucose Monitoring
    Wong, Jenise C.
    Abdulhussein, Fatema
    Yeung, Brittany J.
    Velazquez, Edgar J.
    [J]. DIABETES, 2019, 68
  • [38] Investigating the value of glucodensity analysis of continuous glucose monitoring data in type 1 diabetes: an exploratory analysis
    Cui, Elvis Han
    Goldfine, Allison B.
    Quinlan, Michelle
    James, David A.
    Sverdlov, Oleksandr
    [J]. FRONTIERS IN CLINICAL DIABETES AND HEALTHCARE, 2023, 4
  • [39] Role of continuous glucose monitoring in diabetes management
    Moser, E. G.
    Crew, L. B.
    Garg, S. K.
    [J]. AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 73 - 78
  • [40] A continuous glucose monitoring in type 2 diabetes
    Pavlicek, Vojtech
    [J]. DIABETOLOGE, 2017, 13 (07): : 522 - 524