Value and limitations of the Continuous Glucose Monitoring System in the management of type 1 diabetes

被引:27
|
作者
Melki, V [1 ]
Ayon, F [1 ]
Fernandez, M [1 ]
Hanaire-Broutin, H [1 ]
机构
[1] Hop Rangueil, Serv Diabetol, F-31059 Toulouse 9, France
关键词
type; 1; diabetes; CGMS; glucose sensor; hypoglycaemia;
D O I
10.1016/S1262-3636(07)70258-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The CGMS (Continuous Glucose Monitoring System) is a portable device allowing continuous measuring of glucose. It provides recordings of at least 72 h, during which 288 measures/day are performed. Results are visualised in the form of a set of curves, illustrating the variations in blood glucose levels over time. The quality of the records has often been questioned by several authors. Some of the system's physiologically related limitations can be explained by the less than perfect coincidence of variations in glucose levels observed in the interstitial tissue, where CGMS measurings are done, and in the blood, where calibrations are performed. Other limitations, such as defects in accuracy or in reproducibility of tracings or premature curtailments of recordings, are due to technical weaknesses which were considerably improved during the past few years, particularly with regard to the quality of the electrodes providing a more stable signal over time. In clinical practice, CGMS is a tool for investigating the glycaemic patterns of diabetic patients in conjonction with SMBG. It allows the identification of overlooked hyper- or hypoglycaemia. Generally well accepted, it is a usefull tool to analyse the nocturnal period, or any situation where glucose checks are rare. The visual nature of its results provides a facilitating support in the discussion between the patient and the care-provider during consultations or educational sessions. CGMS utilisation was proposed for guiding treatment adjustment. At present, it is still difficult to state with certainty that this tool allows effective improvement in the metabolic control of patients with type 1 diabetes, in view of the paucity of controlled studies showing an impact on HbA(1c) values or on the frequency of hypoglycaemia, even if such a tendency emerges from most non-controlled intervention trials.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [1] Benefits and limitations of continuous glucose monitoring in type 1 diabetes
    Stone, Jenine Y.
    Bailey, Timothy S.
    [J]. EXPERT REVIEW OF ENDOCRINOLOGY & METABOLISM, 2020, 15 (01) : 41 - 49
  • [2] Continuous glucose monitoring in type 1 diabetes
    Nelly Mauras
    Larry Fox
    Kimberly Englert
    Roy W. Beck
    [J]. Endocrine, 2013, 43 : 41 - 50
  • [3] Continuous glucose monitoring in type 1 diabetes
    Weinzimer S.A.
    Tamborlane W.V.
    Chase P.
    Garg S.K.
    [J]. Current Diabetes Reports, 2004, 4 (2) : 95 - 100
  • [4] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    [J]. ENDOCRINE, 2013, 43 (01) : 41 - 50
  • [5] The value of three-day continuous glucose monitoring of type 1 diabetes patients
    Kim, Soo Kyoung
    Kim, Hee Kyung
    Lee, Jin In
    Hur, Kyu Yeon
    Kim, Kwang-Won
    Lee, Moon-Kyu
    Chung, Hye Soo
    Kim, Sun Wook
    Kim, Jae Hyeon
    [J]. ENDOCRINE JOURNAL, 2010, 57 : S375 - S375
  • [6] Continuous Glucose Monitoring in Youth with Type 1 Diabetes
    Wadwa, R. Paul
    Fiallo-Scharer, Rosanna
    VanderWel, Brandon
    Messer, Laurel H.
    Cobry, Erin
    Chase, H. Peter
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S83 - S91
  • [7] Continuous Glucose Monitoring and Type 1 Diabetes Reply
    Tamborlane, William V.
    Beck, Roy W.
    Laffel, Lori
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (02): : 191 - 192
  • [8] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    [J]. DIABETOLOGE, 2019, 15 (08): : 744 - 746
  • [9] Continuous glucose monitoring in type 1 diabetes mellitus
    Tamborlane, William V.
    Beck, Roy W.
    [J]. LANCET, 2009, 373 (9677): : 1744 - 1746
  • [10] Continuous glucose monitoring in children with type 1 diabetes
    不详
    [J]. JOURNAL OF PEDIATRICS, 2007, 151 (04): : 388 - 393