A simple ultrasensitive electrochemical sensor for simultaneous determination of gallic acid and uric acid in human urine and fruit juices based on zirconia-choline chloride-gold nanoparticles-modified carbon paste electrode

被引:94
|
作者
Shahamirifard, Seyed Alireza [1 ]
Ghaedi, Mehrorang [1 ]
Razmi, Zahra [1 ]
Hajati, Shaaker [2 ]
机构
[1] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[2] MERC, Dept Semicond, POB 31787-316, Tehran, Iran
来源
关键词
Gallic acid; Uric acid; Modified carbon paste electrode; Choline chloride; ASCORBIC-ACID; SENSITIVE DETERMINATION; COMPOSITE; PHENOLICS; GLUCOSE; SURFACE; WINES; ZRO2;
D O I
10.1016/j.bios.2018.05.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of gallic acid (GA) and uric acid (UA) is essential due to their biological properties. Numerous methods have been reported for the analysis of GA and UA in various real samples. However, the development of a simple, rapid and practical sensor still remains a great challenge. Here, a carbon paste electrode (CPE) was modified by nanocomposite containing zirconia nanoparticles (ZrO(2)NPs), Choline chloride (ChCD and gold nanoparticles (AuNPs) to construct ZrO2-ChCI-AuNPs/CPE as electrochemical sensor for the simultaneous electro-oxidation of GA and UA. Characterization was performed by Fourier transform infrared spectroscopy, Xray diffraction, field emission scanning electron microscopy and energy dispersive X-ray spectroscopy. The modified electrode was investigated by different methods including electrochemical impedance spectroscopy and cyclic voltammetry. Kinetic parameters such as charge transfer coefficient, standard heterogeneous electron transfer rate constant and other parameters were calculated via voltammetry techniques. Differential pulse voltammetry was used for simultaneous determination of GA and UA applying the ZrO2-ChCI-AuNPs/CPE electrode. At the optimum conditions, this sensor showed a linear response in the ranges 0.22- 55 and 0.12-55 M for GA and UA, respectively. In addition, low detection limits of 25 and 15 nM were obtained for GA and UA, respectively. Furthermore, ZrO2-ChCI-AuNPs/CPE was successfully applied for the independent determination of GA in green tea and fruit juice as well as the simultaneous determination of GA and UA in human urine samples.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of ascorbic acid, dopamine, and uric acid using a carbon paste electrode modified with multiwalled carbon nanotubes, ionic liquid, and palladium nanoparticles
    Amir Abbas Rafati
    Ahmadreza Afraz
    Ali Hajian
    Parnaz Assari
    Microchimica Acta, 2014, 181 : 1999 - 2008
  • [42] Sensitive electrochemical sensor for simultaneous determination of uric acid and xanthine. in human biological fluids based on the nano-boron doped ceria modified glassy carbon paste electrode
    Ibrahim, Hossieny
    Temerk, Yassien
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 : 176 - 186
  • [43] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [44] Simultaneous determination of ellagic and gallic acid in Punica granatum, Myrtus communis and Itriphal formulation by an electrochemical sensor based on a carbon paste electrode modified with multi-walled carbon nanotubes
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Khayatkashani, Maryam
    Motaghedifard, Mohamad Hasan
    ANALYTICAL METHODS, 2011, 3 (03) : 636 - 645
  • [45] Simultaneous determination of ascorbic acid, dopamine, and uric acid based on double-walled carbon nanotubes/choline-modified electrode
    Xu, Bingbing
    Song, Qijun
    Wang, Haijun
    ANALYTICAL METHODS, 2013, 5 (09) : 2335 - 2342
  • [46] Electrochemical determination of vitamin C in the presence of uric acid by a novel TiO2 nanoparticles modified carbon paste electrode
    Mohammad Mazloum-Ardakani
    Mohammad Ali Sheikh-Mohseni
    Hadi Beitollahi
    Ali Benvidi
    Hossein Naeimi
    Chinese Chemical Letters, 2010, 21 (12) : 1471 - 1474
  • [47] Electrochemical determination of vitamin C in the presence of uric acid by a novel TiO2 nanoparticles modified carbon paste electrode
    Mazloum-Ardakani, Mohammad
    Sheikh-Mohseni, Mohammad Ali
    Beitollahi, Hadi
    Benvidi, Ali
    Naeimi, Hossein
    CHINESE CHEMICAL LETTERS, 2010, 21 (12) : 1471 - 1474
  • [48] Electrochemical Sensor Based on a Carbon Veil Modified by Phytosynthesized Gold Nanoparticles for Determination of Ascorbic Acid
    Brainina, Khiena Z.
    Bukharinova, Maria A.
    Stozhko, Natalia Yu.
    Sokolkov, Sergey V.
    Tarasov, Aleksey V.
    Vidrevich, Marina B.
    SENSORS, 2020, 20 (06)
  • [49] Fabrication of an electrochemical biosensor based on Fe3O4 nanoparticles and uricase modified carbon paste electrode for uric acid determination
    Erdogan, Zehra Ozden
    Kucukkolbasi, Semahat
    MONATSHEFTE FUR CHEMIE, 2021, 152 (03): : 309 - 314
  • [50] Preparation of a new electrochemical sensor based on iron (III) complexes modified carbon paste electrode for simultaneous determination of mefenamic acid and indomethacin
    Hasanzadeh, Mohammad
    Shadjou, Nasrin
    Saghatforoush, Lotfali
    Dolatabadi, Jafar Ezzati Nazhad
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 92 : 91 - 97