Determination of dosimetrical quantities used in microbeam radiation therapy (MRT) with Monte Carlo simulations

被引:105
|
作者
Siegbahn, E. A. [1 ]
Stepanek, J. [1 ]
Brauer-Krisch, E. [1 ]
Bravin, A. [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
dosimetry; synchrotron radiation; microbeam; radiotherapy; Monte Carlo simulations; PENELOPE;
D O I
10.1118/1.2229422
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Microbeam radiation therapy (MRT) is being performed by using an array of narrow rectangular x-ray beams (typical beam sizes 25 mu m x 1 cm), positioned close to each other (typically 200 mu m separation), to irradiate a target tissue. The ratio of peak-to-valley doses (PVDR's) in the composite dose distribution has been found to be strongly correlated with the normal tissue tolerance and the therapeutic effect of MRT. In this work a Monte Carlo (MC) study of the depth- and lateral-dose profiles in water for single x-ray microbeams of different shapes and energies has been performed with the MC code PENELOPE. The contributions to the dose deposition from different interaction types have been determined at different distances from the center of the microbeam. The dependence of the peak dose, in a water phantom, on the microbeam field size used in the preclinical trials, has been demonstrated. Composite dose distributions for an array of microbeams were obtained using superposition algorithms and PVDR's were determined and compared with literature results obtained with other Monte Carlo codes. The dependence of the PVDR's on microbeam width, x-ray energy used, and on the separation between adjacent microbeams has been studied in detail. (c) 2006 American Association of Physicists in Medicine.
引用
下载
收藏
页码:3248 / 3259
页数:12
相关论文
共 50 条
  • [41] MONTE-CARLO MODEL OF PHOTON BEAMS USED IN RADIATION-THERAPY
    LOVELOCK, DMJ
    CHUI, CS
    MOHAN, R
    MEDICAL PHYSICS, 1995, 22 (09) : 1387 - 1394
  • [42] Dosimetrical studies on a tissue level using the MCNP4c2 Monte Carlo simulations
    Larsson, E
    Jönsson, BA
    Jönsson, L
    Ljungberg, M
    Strand, SE
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S258 - S258
  • [43] Determination of Uncertainties for Correlated Input Quantities by the Monte Carlo Method
    Golias, Marcel
    Palencar, Rudolf
    ACTA POLYTECHNICA, 2012, 52 (04) : 57 - 61
  • [44] Monte Carlo simulations of a proton therapy beamline
    Soukup, M
    Weber, A
    Heufelder, J
    Fippel, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S160 - S160
  • [45] Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy
    Cornelius, Iwan
    Guatelli, Susanna
    Fournier, Pauline
    Crosbie, Jeffrey C.
    del Rio, Manuel Sanchez
    Braeuer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 518 - 528
  • [46] Monte Carlo Study of a Compact Distributed X-Ray Source Microbeam Radiation Therapy Research Irradiator
    Schreiber, E.
    Chang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3899 - 3899
  • [47] The GEANT4 toolkit for microdosimetry calculations:: Application to microbeam radiation therapy (MRT)
    Spiga, J.
    Siegbahn, E. A.
    Braeuer-Krisch, E.
    Randaccio, P.
    Bravin, A.
    MEDICAL PHYSICS, 2007, 34 (11) : 4322 - 4330
  • [48] Monte Carlo simulations of the radiation environment for the CMS experiment
    Mallows, S.
    Azhgirey, I.
    Bayshev, I.
    Bergstrom, I.
    Cooijmans, T.
    Dabrowski, A.
    Gloggler, L.
    Guthoff, M.
    Kurochkin, I.
    Vincke, H.
    Tajeda, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 30 - 32
  • [49] Monte Carlo simulations as a tool for radiation damage evaluation
    Ligori, Sebastiano
    Riva, Alberto
    Mauri, Marco
    Corcione, Leonardo
    Bortoletto, Favio
    Bonoli, Carlotta
    Giro, Enrico
    SPACE TELESCOPES AND INSTRUMENTATION 2010: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2010, 7731
  • [50] Monte Carlo simulations of radiation from compact objects
    Liang, E
    Boettcher, M
    Lin, DC
    Smith, I
    FIFTH COMPTON SYMPOSIUM, 2000, 510 : 245 - 249