Bone remodeling around cementless hip implants

被引:16
|
作者
Bugbee, WD [1 ]
Sychterz, CJ [1 ]
Engh, CA [1 ]
机构
[1] ANDERSON ORTHOPAED RES INST, ARLINGTON, VA 22206 USA
关键词
D O I
10.1097/00007611-199611000-00002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone remodeling results from the adaptation of bone to the stresses that act upon it, The insertion of an endoprosthesis into a femur changes the stress distribution within the femur, causing the bone to remodel, In this paper, we show how radiographic bone remodeling changes can be used to determine implant fixation and how bone remodeling changes can be quantitated by using dual-energy x-ray absorptiometry analysis as well as computer-assisted videodensitometry.
引用
收藏
页码:1036 / 1040
页数:5
相关论文
共 50 条
  • [21] Simulated bone remodeling around tilted dental implants in the anterior maxilla
    Chao Wang
    Weiping Zhang
    Deepal Haresh Ajmera
    Yun Zhang
    Yubo Fan
    Ping Ji
    Biomechanics and Modeling in Mechanobiology, 2016, 15 : 701 - 712
  • [22] A histological and biomechanical study of bone stress and bone remodeling around immediately loaded implants
    JingYun Han
    JianXia Hou
    Gang Zhou
    Chao Wang
    YuBo Fan
    Science China Life Sciences, 2014, 57 : 618 - 626
  • [23] A histological and biomechanical study of bone stress and bone remodeling around immediately loaded implants
    Han JingYun
    Hou JianXia
    Zhou Gang
    Wang Chao
    Fan YuBo
    SCIENCE CHINA-LIFE SCIENCES, 2014, 57 (06) : 618 - 626
  • [24] A histological and biomechanical study of bone stress and bone remodeling around immediately loaded implants
    HAN JingYun
    HOU JianXia
    ZHOU Gang
    WANG Chao
    FAN YuBo
    Science China(Life Sciences), 2014, 57 (06) : 618 - 626
  • [25] Influence of ingrowth regions on bone remodelling around a cementless hip resurfacing femoral implant
    Haider, Ifaz T.
    Speirs, Andrew D.
    Beaule, Paul E.
    Frei, Hanspeter
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (12) : 1349 - 1357
  • [26] Improved osseointegration and periprosthetic bone volume around cementless metal implants under bisphosphonate treatment
    Eberhardt, C
    Raussen, W
    Thiemann, S
    Schwarz, M
    Bauss, F
    Kurth, AA
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (06): : 645 - 651
  • [27] Measurement of bone density by DEXA around cementless femoral implants with different porous coating.
    Masuhara, K
    Miki, H
    Nakai, T
    Yamaguchi, K
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (04) : 795 - 795
  • [28] Predictive value of a preoperative biochemical bone marker in relation to bone remodeling after cementless total hip arthroplasty
    Yamaguchi, K
    Masuhara, K
    Yamasaki, S
    Nakai, T
    Fuji, T
    JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (03) : 259 - 265
  • [29] ADAPTIVE BONE REMODELING AROUND CEMENTLESS FEMORAL STEMS WITH TWO DIFFERENT DESIGNS: FITMORE AND ALLOCLASSIC
    Karagodina, M. P.
    Shubnyakov, I. I.
    Tikhilov, R. M.
    Pliev, D. G.
    Denisov, A. O.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2015, (04): : 15 - 28
  • [30] Stem length in primary cementless total hip arthroplasty: Does it make a difference in bone remodeling?
    Samy, Ahmed M.
    El-Tantawy, Ahmad
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (06): : 1235 - 1242