Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty

被引:2
|
作者
Bae, Ji Hoon [1 ]
Lee, Ja-Woon [1 ]
Kim, Soo-Hyun [2 ]
Kim, Sang-Gyun [3 ]
Jeon, Young-Sik [1 ]
Choi, Jeong Seok [1 ]
机构
[1] Korea Univ, Guro Hosp, Dept Orthoped Surg, Coll Med, 148 Gurodong Ro, Seoul 08308, South Korea
[2] Naval Maritime Med Ctr, Dept Orthoped Surg, Jinju 51640, South Korea
[3] Korea Univ, Ansan Hosp, Dept Orthoped Surg, Coll Med, Ansan 15355, South Korea
关键词
Total knee arthroplasty; Tibial torsion; Component rotation;
D O I
10.1007/s00167-020-06429-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Tibiofemoral synchronization technique matches the rotational alignment of the tibial component to the femoral component during the total knee arthroplasty (TKA). The rotational axis of the proximal tibia can be changed by this technique, which affects tibial torsion postoperatively. The purpose of this study was to investigate whether the tibiofemoral synchronization technique affect the tibial torsion, and the lower limb rotation after primary TKA. It was hypothesised that the tibial torsion would change after primary TKA. Methods Ninety-three posterior stabilised TKAs from 89 patients were included from January 2017 to December 2018. Mechanical hip-knee-ankle axis (mHKA), in plain radiographs, femoral anteversion, tibial torsion, femoral neck-malleolar angle (FNMA), and rotational alignment of the femoral and the tibial components in pre- and postoperative CT scans were measured by two blinded observers. The primary outcome was a postoperative change in femoral anteversion, tibial torsion and FNMA. Clinical outcomes were evaluated using the American Knee Society Knee Score (AKSKS)/Function Score (AKSFS), and Oxford Knee Score (OKS) preoperatively and at 1 year after TKA. Patients' perception of changes in the foot progression angle after TKA was investigated. Statistical significance was set at p < 0.05. Results The mean rotational mismatch between the femoral and the tibial component was 0.6 +/- 3.2 degrees. There was a significant decrease in femoral anteversion (9.5 +/- 6.7 degrees vs. 5.2 +/- 6.6 degrees, p < 0.001), and a significant increase in the FNMA (17.6 +/- 9.7 degrees vs. 21.8 +/- 10.5 degrees, p = 0.005) after TKA, while no significant change in tibia torsion was observed (25.4 +/- 8.8 degrees vs. 24.9 +/- 9.3 degrees, p = 0.739). AKSS (37.8 +/- 15.1 vs. 92.8 +/- 8.8, p < 0.001), AKSFS (53.9 +/- 18.1 vs. 89.9 +/- 5.3, p < 0.001), and OKS (18.0 +/- 7.3 vs. 39.9 +/- 4.8, p < 0.001) were significantly improved at 1 year after TKA. Ten knees (11%) had changes in tibial torsion greater than +/- 10 degrees postoperatively. Four of five patients who had changes in FNMA greater than 15 degrees perceived the external rotation of the foot progression angle after TKA. All four patients had an increase in tibial torsion larger than 10 degrees. Conclusion Our study shows that the tibiofemoral synchronization technique less likely affects the tibial torsion after primary TKA.
引用
收藏
页码:698 / 704
页数:7
相关论文
共 50 条
  • [1] Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty
    Ji Hoon Bae
    Ja-Woon Lee
    Soo-Hyun Kim
    Sang-Gyun Kim
    Young-Sik Jeon
    Jeong Seok Choi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 698 - 704
  • [2] The effect of femoral component external rotation on tibial rotation in total knee arthroplasty
    Sherwood, CP
    Zhang, AX
    Petrella, AJ
    Miller, MC
    Berger, RA
    Rubash, HE
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 311 - 312
  • [3] Femoral and tibial component rotation in total knee arthroplasty METHODS AND CONSEQUENCES
    Scott, R. D.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 140 - 143
  • [4] Tibial component rotation in total knee arthroplasty
    Feczko, Peter Z.
    Pijls, Bart G.
    van Steijn, Michael J.
    van Rhijn, Lodewijk W.
    Arts, Jacobus J.
    Emans, Peter J.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [5] Tibial component rotation in total knee arthroplasty
    Peter Z. Feczko
    Bart G. Pijls
    Michael J. van Steijn
    Lodewijk W. van Rhijn
    Jacobus J. Arts
    Peter J. Emans
    BMC Musculoskeletal Disorders, 17
  • [6] The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation
    Jazrawi, LM
    Birdzell, L
    Kummer, FJ
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 761 - 766
  • [7] Femoral component rotation and Laurin angle after total knee arthroplasty
    Classen, Tim
    Wegner, Alexander
    Muller, Ralf-Dietrich
    Von Knoch, Marius
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (01): : 69 - 73
  • [8] The effect of femoral component rotation on patellar tracking in total knee arthroplasty
    Luring, Christian
    Perlick, Lars
    Baethis, Holger
    Tingart, Markus
    Grifka, Joachim
    ORTHOPEDICS, 2007, 30 (11) : 965 - 967
  • [9] Femoral component rotation during total knee arthroplasty
    Olcott, CW
    Scott, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : 39 - 42
  • [10] How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review
    Eduard J. De Valk
    Julia C. A. Noorduyn
    Eduard L. A. R. Mutsaerts
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3517 - 3528