Transcranial high-intensity Doppler signals in patients with mechanical heart valve prostheses: Their relationship with abnormal intracavitary echoes

被引:0
|
作者
Deklunder, G [1 ]
Lecroart, JL [1 ]
Savoye, C [1 ]
Coquet, B [1 ]
Houdas, Y [1 ]
机构
[1] UNIV LILLE, CARDIOL HOSP, LILLE, FRANCE
来源
JOURNAL OF HEART VALVE DISEASE | 1996年 / 5卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: In preceding studies, we reported that abnormal Doppler signals of high intensity (HITS) were frequently found in the cerebral arteries of patients with prosthetic mechanical heart valves. These signals should be attributed either to air microbubbles, possibly due to cavitations or to solid emboli elements. On the other hand, the presence of abnormal intracardiac echoes has been reported in patients with mechanical valves. These echoes should be also attributed to air microbubbles or to formed elements. Although in vitro experiments are in favor of the first explanation, the discussion of their origin remains open. Methods: Among patients subjected to a transesophageal echocardiography (TEE), we selected subjects with mechanical prosthetic heart valves, according to the following criteria: (i) normally functioning valves; (ii) bright echoes suggesting microbubbles, inside the prosthetic valve and/or upstream from it (left ventricular outflow tract or left atrium); (iii) no morphological lesions that could generate solid microemboli at the prosthetic level; (iv) normal carotid arteries, as investigated by color echo-Doppler. Results: Twenty patients were selected: II men and nine women of age range 40-64 years. They were implanted with mechanical heart valves (24 Saint-Jude Medical(TM), three Bjork-Shiley(TM) and one CarboMedics(TM)) in the mitral position (10), aortic position (two), or mitral and aortic position (eight) for periods ranging from 10 days to 17 years. There was no major left ventricular dysfunction (mean end-diastolic diameter 51.8 mm; mean ejection fraction 59%). The mean diameter of the left atrium was 46.1 mm. All but three patients were in sinus rhythm; seven had presented with a transient ischemic attack or amaurosis within the six months preceding the investigation. Immediately after TEE, Doppler signals were recorded on the middle cerebral arteries (MCA) during 10 minutes on each side, and the abnormal Doppler signals were counted. Seventeen subjects (85%) exhibited HITS repetition rate from 0.2 to 5.5 per min. Conclusion: The percentage of patients with HITS in a non-selected group with mechanical heart valves was about 50%, as observed in previous studies. It appears that in a selected group of patients the percentage with HITS is consistently higher. Therefore, HITS and abnormal intracardiac echoes could have a common origin.
引用
收藏
页码:662 / 667
页数:6
相关论文
共 29 条
  • [21] Cerebral High-Intensity Transient Signals during Pediatric Cardiac Catheterization: A Pilot Study Using Transcranial Doppler Ultrasonography
    LaRovere, Kerri L.
    Kapur, Kush
    McElhinney, Doff B.
    Razumovsky, Alexander
    Kussman, Barry D.
    JOURNAL OF NEUROIMAGING, 2017, 27 (04) : 381 - 387
  • [22] Low-Intensity International Normalized Ratio (INR) Oral Anticoagulant Therapy in Chinese Patients with Mechanical Heart Valve Prostheses
    Zhang Haibo
    Li Jinzhong
    Liu Yan
    Meng Xu
    Cell Biochemistry and Biophysics, 2012, 62 : 147 - 151
  • [23] Low-Intensity International Normalized Ratio (INR) Oral Anticoagulant Therapy in Chinese Patients with Mechanical Heart Valve Prostheses
    Zhang Haibo
    Li Jinzhong
    Liu Yan
    Meng Xu
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2012, 62 (01) : 147 - 151
  • [24] Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit™ heart valve prosthesis
    Warnecke, RH
    Laas, J
    Hecker, H
    Perthel, M
    Alken, A
    JOURNAL OF HEART VALVE DISEASE, 2006, 15 (02): : 174 - 179
  • [25] Low-intensity Anticoagulant Treatment in Chinese Patients with Mechanical Heart Valve Prostheses: Early Outcomes of a Prospective, Multicenter Registry in China
    Hu, Jia
    Fu, Bo
    Xu, Jian-ping
    Shi, Ying-kang
    Dong, Li
    CIRCULATION, 2014, 130
  • [26] Classification of high-intensity transient signals into artifacts or solid or gaseous emboli by a panel of signal processing methods combined with dual-gate transcranial Doppler: Final results and whereabouts for the wavelet study group
    Devuyst, G
    Urbano, LA
    Vesin, JM
    Despland, PA
    Bogousslavsky, J
    Darbellay, G
    NEUROLOGY, 2002, 58 (07) : A148 - A148
  • [27] Low-intensity oral anticoagulation plus low-dose aspirin versus high-intensity oral anticoagulation alone: A randomized trial in patients with mechanical prosthetic heart valves
    Meschengieser, SS
    Fondevila, CG
    Frontroth, J
    Santarelli, MT
    Lazzari, MA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (05): : 910 - 916
  • [28] RELATIONSHIP OF COMMON CAROTID-ARTERY HIGH-INTENSITY TRANSIENT SIGNALS IN PATIENTS WITH ISCHEMIC STROKE TO WHITE-MATTER VERSUS TERRITORIAL INFARCT PATTERN ON BRAIN CT SCAN
    TEGELER, CH
    KNAPPERTZ, VA
    NAGARAJA, D
    MOONEY, M
    DALLEY, GM
    CEREBROVASCULAR DISEASES, 1995, 5 (02) : 128 - 132
  • [29] RELATIONSHIP OF COMMON CAROTID-ARTERY HIGH-INTENSITY TRANSIENT SIGNALS IN PATIENTS WITH ISCHEMIC STROKE TO WHITE-MATTER VERSUS TERRITORIAL INFARCT PATTERN ON BRAIN CT SCAN (VOL 5, PG 128, 1995)
    TEGELER, CH
    KNAPPERTZ, VA
    NAGARAJA, D
    MOONEY, M
    DALLEY, GM
    CEREBROVASCULAR DISEASES, 1995, 5 (05) : 327 - 327