Simultaneous determination of four endogenous steroids in bio matrices by LC-MS/MS

被引:4
|
作者
Ranganathan, Premanand [1 ,2 ]
Gunasekaran, V. [2 ]
Singhvi, Indrajeet [3 ]
Alfarraj, Saleh [4 ]
Usmani, Salma [5 ]
Ansari, Mohammad Javed [6 ]
机构
[1] Pacific Acad Higher Educ & Res Univ, Dept Pharm, Udaipur, Rajasthan, India
[2] Raos Coll Pharm, Dept Pharmaceut Chem, Nellore, Andhra Pradesh, India
[3] Pacific Univ, Coll Pharm, Dept Pharmaceut Chem, Udaipur, Rajasthan, India
[4] King Saud Univ, Dept Zool, Coll Sci, Riyadh 11451, Saudi Arabia
[5] DKM Coll Women, Dept Biochem, Vellore 632001, Tamil Nadu, India
[6] Mahatma Jyotiba Phule Rohilkhand Univ, Hindu Coll Moradabad, Dept Bot, Bareilly 244001, Uttar Pradesh, India
关键词
Progesterone; 11; alpha-Hydroxyprogesterone; Corticosterone; Testosterone; Method validation and LCMSMS; MASS-SPECTROMETRY;
D O I
10.1016/j.jksus.2020.101245
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A simple sensitive and accessible ultra-high performance liquid chromatography coupled with triple quadrupole mass spectrometry using AJS-ESI method is established and validated for the intended purpose of quantification of major cholesterol steroidal metabolites Corticosterone, 11 alpha-Hydroxyprogesterone, Testosterone and Progesterone is extracted by Tertiary butyl methyl ether solvent from human plasma and analyzed using Infinity Lab Poroshell 120 EC-C18, (2.1 x 150 mm, 2.7 mu m) column by gradient elution. The Eluent composed of 5 milli molar Ammonium formate in Methanol as eluent A and 5 mM Ammonium formate as eluent B and detection was done by AJSESI fitted tandem mass spectrometry in positive mode. The internal standard used is Caffeine. The quantification lower limits (LLOQ) are 0.200 ng per liter for all four steroids Corticosterone, 11 alpha-Hydroxyprogesterone, Testosterone and Progesterone. The Calibration curve are linear over the respectively limits of 0.200 to 1000.000 ng per milliliter of Plasma for each analyte and quadric for Testosterone. This new LC-MS/MS method shows presentable precision & accuracy and provides satisfactory sensitive for the fulfillment of human pharmacokinetic studies. (C) 2020 The Author(s). Published by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Simultaneous Determination of Pesticide Residues in Agricultural Products by LC-MS/MS
    Watanabe, Minae
    Ueno, Eiji
    Inoue, Tomomi
    Ohno, Haruka
    Ikai, Yoshitomo
    Morishita, Toshio
    Oshima, Harumi
    Hayashi, Rumiko
    FOOD HYGIENE AND SAFETY SCIENCE, 2013, 54 (01): : 14 - 24
  • [22] Simultaneous Determination of Dolutegravir and Lamivudine in Human Plasma by LC-MS/MS
    Bhadru, Banothu
    Rao, V. Venkata
    Vidyadhara, Suryadevara
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, 11 (02): : P90 - P97
  • [23] Simultaneous determination of clofarabine and cytarabine in human plasma by LC-MS/MS
    Buettner, Bozena
    Oertel, Reinhard
    Schetelig, Johannes
    Middeke, Jan Moritz
    Bornhaeuser, Martin
    Seeling, Andreas
    Knoth, Holger
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 125 : 286 - 291
  • [24] Simultaneous LC-MS/MS Determination of 18 Plant Toxins in Beverages
    Oishi, Akifumi
    Nagatomi, Yasushi
    Suzuki, Koji
    FOOD HYGIENE AND SAFETY SCIENCE, 2019, 60 (04): : 108 - 112
  • [25] Simultaneous quantification of 51 steroids in pediatric plasma and urine samples by LC-MS/MS
    Wu, Xiaoyu
    Chen, Yao
    Li, Xiaoqing
    Xue, Peng
    Tang, Jingyi
    Yu, Xiaodan
    Zheng, Liang
    Wang, Xiumin
    Liu, Shijian
    HORMONE RESEARCH IN PAEDIATRICS, 2022, 95 (SUPPL 2): : 370 - 371
  • [26] Investigation of the effects of 24 bio-matrices on the LC-MS/MS analysis of morinidazole
    Lv, Wenxu
    TALANTA, 2010, 80 (03) : 1406 - 1412
  • [27] Development and validation of an SPE methodology combined with LC-MS/MS for the determination of four ionophores in aqueous environmental matrices
    Bak, Soren Alex
    Hansen, Martin
    Krogh, Kristine A.
    Brandt, Asbjorn
    Halling-Sorensen, Bent
    Bjorklund, Erland
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (14) : 1500 - 1512
  • [28] Analysis of steroids in newborn screening by LC-MS/MS
    Fountain, Mark
    Klein, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [29] LC-MS/MS analysis of steroids in the clinical laboratory
    Keevil, Brian G.
    CLINICAL BIOCHEMISTRY, 2016, 49 (13-14) : 989 - 997
  • [30] Simultaneous Determination of Anabolic Androgenic Steroids and Their Esters in Hair by LC–MS–MS
    Min Shen
    Hui Yan
    Ping Xiang
    Baohua Shen
    Chromatographia, 2009, 70 : 1381 - 1386