Transaortic Implantation of Aortic Valve Bioprosthesis in High-Risk Patient With Simultaneous Off-Pump Coronary Artery Bypass Grafting

被引:0
|
作者
Akchurin, R. S. [1 ]
Imaev, T. J. [1 ]
Komlev, A. E. [1 ]
Lepilin, P. M. [1 ]
Kolegaev, A. S. [1 ]
Nikonova, M. E. [1 ]
机构
[1] Russian Cardiol Res & Prod Complex, Moscow, Russia
关键词
aortic stenosis; coronary heart disease (CHD); coronary artery bypass grafting (CABG); transcatheter aortic valve implantation (TAVI); transaortic approach; ASCENDING AORTA; FEASIBILITY; REPLACEMENT; OPTION;
D O I
10.18565/cardio.2016.12.106-110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transaortic approach represents an alternative variant of transcatheter aortic valve implantation (TAVI) which combines benefits of antegrade transapical approach and high safety profile characteristic of transfemoral approach. This method has substantial advantages over subclavian and transapical approaches in cases of pronounced myocardial hypertrophy, left ventricular dysfunction, thinning of left ventricular wall. We describe here a hybrid intervention with simultaneous coronary artery bypass grafting and TAVI in a patient from high surgical risk group with multivessel coronary artery involvement and critical aortic stenosis. The intervention was a successful alternative to open heart surgery with cardiopulmonary bypass.
引用
下载
收藏
页码:106 / 110
页数:5
相关论文
共 50 条
  • [21] Study of Off-pump coronary artery bypass grafting in high risk patients
    S Mehta
    U Shah
    A Patel
    Indian Journal of Thoracic and Cardiovascular Surgery, 2006, 22 (1) : 69 - 69
  • [22] Off-pump coronary artery bypass grafting
    Abu-Omar, Y
    Taggart, DP
    LANCET, 2002, 360 (9329): : 327 - 329
  • [23] Off-pump coronary artery bypass in very high-risk patients
    Schmitz, C
    Bimmel, D
    Ashraf, O
    Esmailzadeh, B
    Likungu, JA
    Schiller, W
    Westhofen, P
    Welz, A
    49TH INTERNATIONAL CONGRESS OF THE EUROPEAN SOCIETY FOR CARDIOVASCULAR SURGERY, 2000, : 115 - 117
  • [24] Randomized trial comparing off-pump to on-pump coronary artery bypass grafting in high-risk patients
    Carrier, M
    Perrault, LP
    Jeanmart, H
    Martineau, R
    Cartier, R
    Pagé, P
    HEART SURGERY FORUM, 2003, 6 (06): : E89 - E92
  • [25] Prophylactic Application of an Intra-Aortic Balloon Pump in High-Risk Patients Undergoing Off-Pump Coronary Artery Bypass Grafting
    Ding, WenJun
    Ji, Qiang
    Wei, Qiang
    Shi, YunQing
    Ma, RunHua
    Wang, ChunSheng
    CARDIOLOGY, 2015, 131 (02) : 109 - 115
  • [26] Off-pump strategy in high-risk coronary artery bypass reoperations
    Ngaage, Dumbor L.
    Zehr, Kenton J.
    Daly, Richard C.
    Sundt, Thoralf M., III
    Mullany, Charles J.
    Dearani, Joseph A.
    Orszulak, Thomas A.
    Schaff, Hartzell V.
    MAYO CLINIC PROCEEDINGS, 2007, 82 (05) : 567 - 571
  • [27] Off-pump coronary artery bypass grafting - Excellent results in a group of selected high-risk patients
    Bittner, HB
    Savitt, MA
    McKeown, PP
    Lucke, JC
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (04): : 451 - 456
  • [28] Evaluation of the effectiveness of off-pump coronary artery bypass grafting in high-risk patients: An observational study
    Chamberlain, MH
    Ascione, R
    Reeves, BC
    Angelini, GD
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1866 - 1873
  • [29] Off-pump coronary artery bypass grafting in a patient with liver cirrhosis
    Taira Yamamoto
    Kenji Takazawa
    Akifusa Hariya
    Noboru Ishikawa
    Shizuyuki Dohi
    Satoshi Matsushita
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (12): : 526 - 529
  • [30] Transapical Aortic Valve Implantation and 'Off-Pump' Arterial Coronary Bypass in a Patient with a Porcelain Aorta
    Pasic, Miralem
    Unbehaun, Axel
    Buz, Semih
    Drews, Thorsten
    Hetzer, Roland
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (06): : 711 - 714