摘要
Presented in this paper is an automated scanning procedure of a dental impression that utilizes an SLS (Structured Light System). The proposed procedure identifies missing areas from the initial scanning data from default orientations and attempts to locate additional scanning orientations to fill the missing areas. The core part of the proposed procedure is an algorithm that computes additional scanning orientations using the information of the missing areas. The algorithm was designed carefully by considering three major technological requirements of the problem: dual visibility, reliability, and efficiency. To satisfy the dual visibility requirement, the proposed algorithm uses the concept of a visibility map as well as the diameter of a spherical polygon. Once dual visibility is satisfied, the proposed algorithm attempts to locate the optimal scanning orientation to maximize the reliability (accuracy) of the scanning data by finding the centroid of a convex spherical polygon. As the proposed procedure is based on well-known 2D geometric algorithms, it is very efficient. The applications of the proposed procedure include not only dental impressions but also other small objects that do not have CAD models. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:404 / 411
页数:8
相关论文
共 50 条
  • [21] Disinfection of dental impressions – compliance to accepted standards
    N. Almortadi
    R. G. Chadwick
    British Dental Journal, 2010, 209 : 607 - 611
  • [22] A Paradigm shift in the concept for making dental impressions
    Nayar, Sanjna
    Mahadevan, R.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2015, 7 (05): : S213 - S215
  • [23] BACTEREMIA ASSOCIATED WITH IRREVERSIBLE HYDROCOLLOID DENTAL IMPRESSIONS
    STANKEWITZ, CG
    CARPENTER, WM
    KATE, W
    JOURNAL OF PROSTHETIC DENTISTRY, 1980, 44 (03): : 251 - 253
  • [24] Dental impressions: Metal rim lock trays
    J. S. Hans
    British Dental Journal, 2016, 220 (3) : 89 - 90
  • [25] PRELIMINARY INVESTIGATION OF A METHOD FOR DISINFECTION OF DENTAL IMPRESSIONS
    MERCHANT, VA
    MCNEIGHT, MK
    CIBOROWSKI, CJ
    MOLINARI, JA
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (06): : 877 - 879
  • [26] Disinfection of dental impressions - compliance to accepted standards
    Almortadi, N.
    Chadwick, R. G.
    BRITISH DENTAL JOURNAL, 2010, 209 (12) : 607 - 611
  • [27] Disinfection of dental impressions by ultraviolet radiation.
    Fiehn, NE
    Larsen, T
    Peutzfeldt, A
    Owall, B
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 852 - 852
  • [28] Current status of disinfection of dental impressions in Indian dental colleges: a cause of concern
    Marya, Charu Mohan
    Shukla, Prasoon
    Dahiya, Vandana
    Jnaneswar, Avinash
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2011, 5 (11): : 776 - 780
  • [29] A survey of the methods of disinfection of dental impressions used in dental hospitals in the United Kingdom
    Blair, FM
    Wassell, RW
    BRITISH DENTAL JOURNAL, 1996, 180 (10) : 369 - 375
  • [30] AUTOMATED SCANNING ELLIPSOMETER
    SMITH, T
    SURFACE SCIENCE, 1976, 56 (01) : 212 - 220