The Clinical Rationale for the Sentry Bioconvertible Inferior Vena Cava Filter for the Prevention of Pulmonary Embolism

被引:6
|
作者
Dake, Michael D. [1 ,2 ]
Ansel, Gary M. [3 ]
Johnson, Matthew S. [4 ]
Mendes, Robert [5 ]
Smouse, H. Bob [6 ]
机构
[1] Univ Arizona Hlth Sci, Dept Med Imaging, Tucson, AZ 85721 USA
[2] Univ Arizona Hlth Sci, Dept Surg, Tucson, AZ 85721 USA
[3] OhioHlth Riverside Methodist Hosp, Dept Cardiol & Vasc Med, Columbus, OH USA
[4] Indiana Univ Sch Med, Dept Vasc & Intervent Radiol, Indianapolis, IN 46202 USA
[5] UNC Rex Hosp, NC Heart & Vasc Res, Dept Vasc Surg, Raleigh, NC USA
[6] OSF St Francis Med Ctr, Dept Intervent Radiol, Peoria, IL USA
关键词
VENOUS THROMBOEMBOLISM;
D O I
10.1155/2019/5795148
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The Sentry inferior vena cava (IVC) filter is designed to provide temporary protection against pulmonary embolism (PE) during transient high-risk periods and then to bioconvert after 60 days after implantation. At the time of bioconversion, the device's nitinol arms retract from the filtering position into the caval wall. Subsequently, the stable stent-like nitinol frame is endothelialized. The Sentry bioconvertible IVC filter has been evaluated in a multicenter investigational-device-exemption pivotal trial (NCT01975090) of 129 patients with documented deep vein thrombosis (DVT) or PE, or at temporary risk of developing DVT or PE, and with contraindications to anticoagulation. Successful filter conversion was observed in 95.7% of patients at 6 months (110/115) and 96.4% at 12 months (106/110). Through 12 months, there were no cases of symptomatic PE. The rationale for development of the Sentry bioconvertible device includes the following considerations: (1) the period of highest risk of PE for the vast majority of patients occurs within the first 60 days after an index event, with most of the PEs occurring in the first 30 days; (2) the design of retrievable IVC filters to support their removal after a transitory high-PE-risk period has, in practice, been associated with insecure filter dynamics and time-dependent complications including tilting, fracture, embolization, migration, and IVC perforation; (3) most retrievable IVC filters are placed for temporary protection, but for a variety of reasons they are not removed in any more than half of implanted patients, and when removal is attempted, the procedure is not always successful even with advanced techniques; and (4) analysis of Medicare hospital data suggests that payment for the retrieval procedure does not routinely compensate for expense. The Sentry device is not intended for removal after bioconversion. In initial clinical use, complications have been limited. Long-term results for the Sentry bioconvertible IVC filter are anticipated soon.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Fatal pulmonary embolism despite an inferior vena cava filter in glioblastoma multiforme
    Robert Cavaliere
    David Schiff
    [J]. Neurocritical Care, 2005, 3 : 249 - 250
  • [32] VENA-CAVA FILTER IN PREVENTION OF RECURRENT PULMONARY-EMBOLISM
    SCHLOSSER, V
    BIRZLE, H
    KAISER, W
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1972, 97 (20) : 794 - +
  • [33] LIGATION OF THE INFERIOR VENA CAVA FOR THE PREVENTION OF PULMONARY EMBOLISM - A REPORT OF 2 CASES
    GASTON, EA
    FOLSOM, H
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1945, 233 (08): : 229 - 233
  • [34] PREVENTION OF PULMONARY-EMBOLISM IN PATIENTS WITH DUAL INFERIOR VENA-CAVA
    ICARD, P
    BONNICHON, P
    FARHI, JP
    CHAPUIS, Y
    [J]. PRESSE MEDICALE, 1986, 15 (44): : 2213 - 2213
  • [35] INTERRUPTION OF THE INFERIOR VENA-CAVA FOR THE PREVENTION OF RECURRENT PULMONARY-EMBOLISM
    MANSOUR, M
    CHANG, AE
    SINDELAR, WF
    [J]. AMERICAN SURGEON, 1985, 51 (07) : 375 - 380
  • [36] PARTIAL INFERIOR VENA-CAVA INTERRUPTION FOR PREVENTION OF PULMONARY-EMBOLISM
    ALEMANY, J
    TEUBNER, K
    MONTAG, H
    [J]. ZENTRALBLATT FUR CHIRURGIE, 1985, 110 (24): : 1507 - 1514
  • [37] INFERIOR VENA CAVA PLICATION FOR PREVENTION OF PULMONARY EMBOLISM - RESULTS IN 24 CASES
    BURGET, DE
    HENZEL, JH
    SMITH, JL
    PORIES, WJ
    [J]. ANNALS OF SURGERY, 1967, 165 (03) : 437 - &
  • [38] INTERRUPTION OF DOUBLE INFERIOR VENA-CAVA FOR PREVENTION OF PULMONARY-EMBOLISM
    MEIER, MA
    BURMAN, SO
    HASTREIT.AR
    LONG, DM
    [J]. ANNALS OF SURGERY, 1972, 176 (06) : 769 - 771
  • [39] Prevention of Pulmonary Cement Embolism by Inferior Vena Cava Filter following Vertebroplasty-related Cement Intravasation
    Prater, Stephanie
    Awan, Muhammad Ali
    Antuna, Kristina
    Colon, Julio Zayas
    [J]. JOURNAL OF RADIOLOGY CASE REPORTS, 2021, 15 (04): : 17 - 27
  • [40] Tumoral thrombosis of the inferior vena cava and pulmonary embolism
    Vazquez, Alejandro
    Estevez, Vanesa
    Garcia, Aritz
    Juan, Joaquin U.
    Ramos, Macarena
    Martinez Leon, Juan
    [J]. CIRUGIA CARDIOVASCULAR, 2008, 15 (02): : 209 - 210