Evaluation of transient elastography in assessing liver fibrosis in patients with autoimmune hepatitis

被引:61
|
作者
Xu, Qinyu [1 ,2 ,3 ]
Sheng, Li [1 ,2 ,3 ]
Bao, Han [1 ,2 ,3 ]
Chen, Xiaoyu [1 ,2 ,3 ]
Guo, Canjie [1 ,2 ,3 ]
Li, Hai [1 ,2 ,3 ]
Ma, Xiong [1 ,2 ,3 ]
Qiu, Dekai [1 ,2 ,3 ]
Hua, Jing [1 ,2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Inst Digest Disease, Div Gastroenterol & Hepatol, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Minist Hlth, Key Lab Gastroenterol & Hepatol, Shanghai 200127, Peoples R China
[3] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, 160 Pu Jian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
autoimmune hepatitis; liver fibrosis; liver stiffness measurement; transient elastography; SIMPLE NONINVASIVE INDEX; CHRONIC VIRAL-HEPATITIS; STIFFNESS MEASUREMENT; PORTAL-HYPERTENSION; DIAGNOSIS; PREDICT; AMINOTRANSFERASE; CIRRHOSIS; ACCURACY; APRI;
D O I
10.1111/jgh.13508
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Transient elastography (TE) can reliably stage liver fibrosis via liver stiffness measurement (LSM) in chronic liver disease. However, the accuracy of TE for assessment of liver fibrosis in patients with autoimmune hepatitis (AIH) is still limited. We evaluate TE in staging liver fibrosis in AIH patients and compare with other noninvasive diagnostic tools. Methods: A total of 100 patients with biopsy-proven AIH were included. The correlation between LSM and fibrosis stage was analyzed using Spearman correlation test. The optimal cut-off values of LSM were calculated for predicting individual fibrosis stages using receiver-operating characteristic curve. The diagnostic accuracy of LSM for severe fibrosis was compared with those of serum biochemical scores. Results: Median LSM in AIH patients was higher than that of healthy controls (11.2 +/- 8.2 kPa vs 4.3 +/- 1.4 kPa, P < 0.01). LSM had significant correlation with fibrosis (r = 0.752, P < 0.01) and increased progressively with increasing fibrosis stages in AIH patients. AUROC values of LSM for stages F >= 2, F >= 3, and F4 were 0.878 (95%CI: 0.789-0.967), 0.883 (0.820-0.946), and 0.914 (0.852-0.976), respectively. The optimal cut-off values of LSM for fibrosis stages F = 2, F = 3, and F4 were 6.45, 8.75, and 12.50 kPa, respectively. LSM was superior to APRI score and FIB-4 score in detecting severe fibrosis (F >= 3). Serum ALT levels had minor effect on LSM values. Conclusions: Transient elastography is an accurate and reliable noninvasive tool in assessing liver fibrosis in AIH. Hepatic inflammatory activity had no significant effect on LSM determination.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [31] Combination of Transient Elastography and an Enhanced Liver Fibrosis Test to Assess the Degree of Liver Fibrosis in Patients with Chronic Hepatitis B
    Heo, Ja Yoon
    Kim, Beom Kyung
    Park, Jun Yong
    Kim, Do Young
    Ahn, Sang Hoon
    Kim, Hyon-Suk
    Park, Young Nyun
    Han, Kwang-Hyub
    Song, Kijun
    Kim, Seung Up
    GUT AND LIVER, 2018, 12 (02) : 190 - 200
  • [33] Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography
    Paul, Shashi B.
    Das, Prasenjit
    Mahanta, Mousumi
    Sreenivas, Vishnubhatla
    Kedia, Saurabh
    Kalra, Nancy
    Kaur, Harpreet
    Vijayvargiya, Maneesh
    Ghosh, Shouriyo
    Gamanagatti, Shivanand R.
    Shalimar
    Gupta, Siddhartha Dutta
    Acharya, Subrat K.
    ABDOMINAL RADIOLOGY, 2017, 42 (12) : 2864 - 2873
  • [34] Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography
    Shashi B. Paul
    Prasenjit Das
    Mousumi Mahanta
    Vishnubhatla Sreenivas
    Saurabh Kedia
    Nancy Kalra
    Harpreet Kaur
    Maneesh Vijayvargiya
    Shouriyo Ghosh
    Shivanand R. Gamanagatti
    Siddhartha Dutta Shalimar
    Subrat K. Gupta
    Abdominal Radiology, 2017, 42 : 2864 - 2873
  • [35] Noninvasive inflammatory markers for assessing liver fibrosis stage in autoimmune hepatitis patients
    Yuan, Xiaoling
    Duan, Sheng-Zhong
    Cao, Junying
    Gao, Nan
    Xu, Jie
    Zhang, Lanjing
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2019, 31 (11) : 1467 - 1474
  • [36] ACCURACY OF TRANSIENT ELASTOGRAPHY IN PREDICTING HISTOLOGICAL FIBROSIS SEVERITY IN TREATED AUTOIMMUNE HEPATITIS?
    Harrison, L.
    McFarlane, E.
    Dube, A.
    Gleeson, D.
    GUT, 2016, 65 : A268 - A269
  • [37] THE VALUE OF TRANSIENT ELASTOGRAPHY AND SAMPLE SEROLOGICAL TEST FOR THE EVALUATION OF LIVER FIBROSIS IN CHRONIC HCV HEPATITIS
    Bota, S.
    Sirli, R.
    Sporea, I.
    Focsa, M.
    Popescu, A.
    Danila, M.
    Strain, M.
    Sendroiu, M.
    Deleanu, A.
    Tudora, A.
    Dan, I.
    JOURNAL OF HEPATOLOGY, 2011, 54 : S128 - S128
  • [38] Assessing the consistency of liver fibrosis results obtained through biopsy and transient elastography in patients suffering from chronic hepatitis C
    Pokora, Agnieszka
    Kiciak, Slawomir
    Tomasiewicz, Krzysztof
    CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2016, 2 (03) : 109 - 111
  • [39] Analysis of discordance between transient elastography and liver biopsy for assessing liver fibrosis in chronic hepatitis B virus infection
    Kumar, Manoj
    Rastogi, Archana
    Singh, Tarandeep
    Bihari, Chhagan
    Gupta, Ekta
    Sharma, Praveen
    Garg, Hitendra
    Kumar, Ramesh
    Bhatia, Vikram
    Tyagi, Pankaj
    Sarin, Shiv K.
    HEPATOLOGY INTERNATIONAL, 2013, 7 (01) : 134 - 143
  • [40] Disproportionally high results of transient elastography in patients with autoimmune hepatitis
    Romanque, Pamela
    Stickel, Felix
    Dufour, Jean-Francois
    LIVER INTERNATIONAL, 2008, 28 (08) : 1177 - 1178