Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector

被引:54
|
作者
Shikhaliev, Polad M. [1 ]
机构
[1] Louisiana State Univ, Dept Phys & Astron, Imaging Phys Lab, Baton Rouge, LA 70803 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 16期
关键词
DIGITAL MAMMOGRAPHY; COMPUTED-TOMOGRAPHY;
D O I
10.1088/0031-9155/54/16/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The signal-to-noise ratio (SNR) in x-ray imaging can be increased using a photon counting detector which could allow for rejecting electronics noise and for weighting x-ray photons according to their energies. This approach, however, was not feasible for a long time because photon counting x-ray detectors with very high count rates, good energy resolution and a large number of small pixels were required. These problems have been addressed with the advent of new detector materials, fast readout electronics and powerful computers. In this work, we report on the experimental evaluation of projection x-ray imaging with a photon counting cadmium-zinc-telluride (CZT) detector with energy resolving capabilities. The detector included two rows of pixels with 128 pixels per row with 0.9 x 0.9 mm(2) pixel size, and a 2 Mcount pixel(-1) s(-1) count rate. The x-ray tube operated at 120 kVp tube voltage with 2 mm Al-equivalent inherent filtration. The x-ray spectrum was split into five regions, and five independent x-ray images were acquired at a time. These five quasi-monochromatic x-ray images were used for x-ray energy weighting and material decomposition. A tissue-equivalent phantom was used including contrast elements simulating adipose, calcifications, iodine and air. X-ray energy weighting improved the SNR of calcifications and iodine by a factor of 1.32 and 1.36, respectively, as compared to charge integrating. Material decomposition was performed by dual energy subtraction. The low-and high-energy images were generated in the energy ranges of 25-60 keV and 60-120 keV, respectively, by combining five monochromatic image data into two. X-ray energy weighting was applied to low-and high-energy images prior to subtraction, and this improved the SNR of calcifications and iodine in dual energy subtracted images by a factor of 1.34 and 1.25, respectively, as compared to charge integrating. The detector energy resolution, spatial resolution, linearity, count rate, noise and image uniformity were investigated. The limitations of this technology were emphasized and possible solutions were discussed.
引用
收藏
页码:4971 / 4992
页数:22
相关论文
共 50 条
  • [1] The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector
    Choi, Yu-Na
    Lee, Seung-Wan
    Cho, Hyo-Min
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (05) : 3114 - 3119
  • [2] Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging
    Shikhaliev, Polad M
    Physics in Medicine and Biology, 2006, 51 (17): : 4267 - 4287
  • [3] The effect of energy weighting on x-ray imaging based on photon counting detector: a Monte Carlo simulation
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] Image quality assessment of a photon counting detector in X-ray projection imaging
    Ghani, Muhammad U.
    Li, Yuhua
    Wu, Xizeng
    Liu, Hong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 939 : 83 - 88
  • [5] Energy Weighting in a 2D-MHSP x-ray Single Photon Detector
    Oliveira, C. A. B.
    Santos, C. A.
    Silva, A. L. M.
    Dos Santos, J. M. F.
    Veloso, J. F. C. A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3261 - +
  • [6] Energy Weighting in a 2D-MHSP X-Ray Single Photon Detector
    Oliveira, C. A. B.
    Santos, C. A.
    Carramate, L. F.
    Silva, A. L. M.
    da Luz, Natal
    dos Santos, J. M. F.
    Veloso, J. F. C. A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 938 - 943
  • [7] Photon counting energy dispersive detector arrays for x-ray imaging
    Iwanczyk, J. S.
    Nygard, E.
    Meirav, O.
    Arenson, J.
    Barber, W. C.
    Hartsough, N. E.
    Malakhov, N.
    Wessel, J. C.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2741 - +
  • [8] Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging
    Iwanczyk, Jan S.
    Nygard, Einar
    Meirav, Oded
    Arenson, Jerry
    Barber, William C.
    Hartsough, Neal E.
    Malakhov, Nail
    Wessel, Jan C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 535 - 542
  • [9] Prototype of Flexible Digital X-Ray Imaging Detector
    Kwon, Seyeoul
    Andrew Parker, Charles
    Paetow, Kristofer
    Reed, Hunter
    Chahid, Sara
    Jo Han, Geun
    Widjaja, Agus
    Cho, Jinhui
    Cadena, Kevin
    Granaas, Kevin
    Crocco, Jerome
    IEEE ELECTRON DEVICE LETTERS, 2024, 45 (12) : 2439 - 2442
  • [10] Detector technologies for photon counting/energy resolving x-ray and CT imaging
    Shikhaliev, P. M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2554 - 2555