Optical quality and visual performance with customised soft contact lenses for keratoconus

被引:30
|
作者
Jinabhai, Amit [1 ]
O'Donnell, Clare [1 ,2 ,3 ]
Tromans, Cindy [1 ,4 ]
Radhakrishnan, Hema [1 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Optegra Eye Hosp, Optegra Eye Sci, Manchester, Lancs, England
[3] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[4] Cent Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
关键词
aberration-controlling contact lenses; coma aberrations; higher-order aberrations; keratoconus; rigid gas-permeable contact lenses; toric soft contact lenses; HIGHER-ORDER ABERRATIONS; WAVE-FRONT ABERRATION; OCULAR ABERRATIONS; EYES; ACUITY; COMPENSATION; REFRACTION; SURFACE; SIGNS; WEAR;
D O I
10.1111/opo.12133
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p <= 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p <= 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p <= 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations.
引用
收藏
页码:528 / 539
页数:12
相关论文
共 50 条
  • [31] Optical quality and visual performance obtained with myopia controlling multifocal contact lenses in multivergence scenes
    McDougal, Lauryn
    Khushashi, Maher
    Kashif, Liza
    De Gracia, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [32] Do visual performance and optical quality vary across different contact lens correction modalities in keratoconus?
    Kumar, Preetam
    Bandela, Praveen K.
    Bharadwaj, Shrikant R.
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (06): : 568 - 576
  • [33] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022,
  • [34] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022, 66 (04) : 350 - 357
  • [35] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Takahiro Hiraoka
    Gaku Kiuchi
    Reia Hiraoka
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2022, 66 : 350 - 357
  • [36] Predicting visual performance from optical quality metrics in keratoconus
    Schoneveld, Paul
    Pesudovs, Konrad
    Coster, Douglas J.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (03) : 289 - 296
  • [37] Optical Quality and Vision with Iris-Coloring Soft Contact Lenses
    Ortiz, Carolina
    Jimenez, Raimundo
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (05) : 564 - 569
  • [38] On-eye evaluation of optical performance of rigid and soft contact lenses
    Hong, X
    Himebaugh, N
    Thibos, LN
    OPTOMETRY AND VISION SCIENCE, 2001, 78 (12) : 872 - 880
  • [39] Optical performance of different soft contact lenses based on wavefront analysis
    Fagnani Gatti, Roberta
    Lipener, Cesar
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (06) : 42 - 46
  • [40] Power Profiles and Short-Term Visual Performance of Soft Contact Lenses
    Papas, Eric
    Dahms, Anne
    Carnt, Nicole
    Tahhan, Nina
    Ehrmann, Klaus
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (04) : 318 - 323