Formation of a mercury plated carbon paste electrode by electro reduction of a mercury(II) diethyldithiocarbamate modified carbon paste

被引:8
|
作者
Guo, SX
Khoo, SB
机构
[1] National University of Singapore,Department of Chemistry
关键词
D O I
10.1023/A:1005726016600
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel approach to formation of a mercury film electrode (MFE) at the surface of a carbon paste electrode is proposed in this paper. This MFE is easy to fabricate, has good reproducibility and avoids the use of a plating mercury solution. In this new type of MFE, mercuric diethyldithiocarbamate (Hg(DDTC)(2)) was mixed with graphite powder and paraffin oil to form a chemically modified carbon paste electrode. When a -0.95V potential was applied to the electrode, the Hg(II) (in Hg(DDTC)2) was reduced to metallic Hg, thus forming a mercury film at the surface of the carbon paste electrode. The characteristics of this MFE were studied. This modified electrode was used in anodic stripping voltammetry. Conditions for the simultaneous determination of trace amount of Pb(II) and Cd(II) were also investigated.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 50 条
  • [31] Anodic stripping voltammetric determination of mercury in water using a chitosan-modified carbon paste electrode
    Marcolino, Luiz H. Junior
    Janegitz, Bruno C.
    Lourencao, Bruna C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3119 - 3128
  • [32] Determination of mercury and silver at a modified carbon paste electrode containing glyoxal bis(2-hydroxyanil)
    Won, MS
    Moon, DW
    Shim, YB
    ELECTROANALYSIS, 1995, 7 (12) : 1171 - 1176
  • [33] Electrochemically Deposited Gold Nanoparticles on a Carbon Paste Electrode Surface for the Determination of Mercury
    Sahoo, Srikant
    Satpati, Ashis Kumar
    Reddy, Annareddy Venkata Ramana
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (02) : 506 - 511
  • [34] Indirect Determination of Mercury by Inhibition of Glucose Oxidase Immobilized on a Carbon Paste Electrode
    Samphao, A.
    Rerkchai, H.
    Jitcharoen, J.
    Nacapricha, D.
    Kalcher, K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (02): : 1001 - 1010
  • [35] USE OF CARBON PASTE ELECTRODE FOR INVERSE VOLTAMMETRIC DETERMINATION OF SMALL QUANTITIES OF MERCURY
    ULRICH, L
    RUEGSEGGER, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1975, 277 (05): : 349 - 353
  • [36] Ion-selective carbon paste electrode based on tetraethyl thiuram disulfide for copper(II) and mercury(II)
    Gismera, MJ
    Hueso, D
    Procopio, JR
    Sevilla, AT
    ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) : 347 - 353
  • [37] DEVELOPMENT OF A CHEMICALLY MODIFIED ELECTRODE BASED ON CARBON PASTE AND FUNCTIONALIZED SILICA-GEL FOR PRECONCENTRATION AND VOLTAMMETRIC DETERMINATION OF MERCURY(II)
    ALEIXO, LM
    SOUZA, MDB
    GODINHO, OES
    NETO, GD
    GUSHIKEM, Y
    MOREIRA, JC
    ANALYTICA CHIMICA ACTA, 1993, 271 (01) : 143 - 148
  • [38] A novel chemically modified carbon paste electrode based on a new mercury(II) complex for selective potentiometric determination of bromide ion
    Shamsipur, M
    Ershad, S
    Samadi, N
    Moghimi, A
    Aghabozorg, H
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2005, 9 (11) : 788 - 793
  • [39] A novel chemically modified carbon paste electrode based on a new mercury(II) complex for selective potentiometric determination of bromide ion
    Mojtaba Shamsipur
    Sohrab Ershad
    Naser Samadi
    Abloghasem Moghimi
    Hossein Aghabozorg
    Journal of Solid State Electrochemistry, 2005, 9 : 788 - 793
  • [40] VOLTAMMETRIC DETERMINATION OF MERCURY(II) AT A CARBON PASTE ELECTRODE IN AQUEOUS-SOLUTIONS CONTAINING TETRAPHENYLBORATE ION
    SVANCARA, I
    VYTRAS, K
    HUA, C
    SMYTH, MR
    TALANTA, 1992, 39 (04) : 391 - 396