Magnetic Nanoparticles in Macrophages and Cancer Cells Exhibit Different Signal Behavior on Magnetic Particle Imaging

被引:14
|
作者
Suzuka, Hisaaki [1 ,2 ,3 ]
Mimura, Atsushi [1 ]
Inaoka, Yoshimi [1 ]
Murase, Kenya [1 ,3 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Technol & Sci, Dept Med Phys & Engn,Fac Hlth Sci, 1-7 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Mol Neurosci, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
[3] Osaka Univ Yamadaoka, Global Ctr Med Engn & Informat, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
Nanoparticles; Magnetic Particle Imaging; Magnetic Particle Spectroscopy; Cell Tracking; Drug Delivery; Nanomedicine; Cell Labeling; Clinical Imaging; Theranostics; Tomography; Macrophages; TRACKING; RELAXATION; PROTAMINE; AC; FERUMOXIDES; MPI;
D O I
10.1166/jnn.2019.16619
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cell labeling with magnetic nanoparticles (MNPs) is a promising method of cell tracking. In particular, a novel quantitative tomography method called magnetic particle imaging (MPI) has the potential to estimate the number of successfully transplanted MNP-labeled cells, thereby helping predict clinical outcomes. However, the biological factors that shape the MPI signals of MNPs during cell labeling are not well understood. To better understand these factors, the MPI signals of MNPs in various extracellular and intracellular conditions were assessed. Firstly, carboxydextran-coated MNPs (Resovist((R))) in the presence or absence of the transfection agents heparin and/or protamine were subjected to dynamic light scattering analysis and magnetic particle spectroscopy. Secondly, RAW264 macrophages and Colon26 carcinoma cells were labeled with Resovist((R)) by using their intrinsic phagocytic activity or with the assistance of the transfection agents, respectively, after which the cells were visualized by our MPI scanner and transmission electron microscopy, and their absolute amounts of intracellular iron were measured by thiocyanate colorimetry. The MPI pixel values were normalized to intracellular iron concentrations. Finally, the effect of cell lysis on the MPI signal was assessed with magnetic particle spectroscopy. The presence of protamine, but not heparin, increased the hydrodynamic diameter of the MNPs and inhibited their MPI signals. Cell uptake drastically decreased the normalized MPI pixel values. This was particularly marked in the colon cancer cells. The transfection agents did not further alter the MPI signal of the MNP-labeled colon cancer cells. Transmission electron microscopy showed that there was much more MNP aggregation in colon cancer cells than in macrophages. After the MNP-labeled cells were lysed, the MPI signal recovered partially. In conclusion, MPI pixel values can be influenced by the cell-labeling process and cellular uptake. The MPI signals from intracellular magnetic nanoparticles may also differ depending on the cell type.
引用
收藏
页码:6857 / 6865
页数:9
相关论文
共 50 条
  • [1] Labeling of Cancer Cells with Magnetic Nanoparticles for Magnetic Resonance Imaging
    Weis, Christian
    Blank, Fabian
    West, Adrian
    Black, Gregory
    Woodward, Robert C.
    Carroll, Matthew R. J.
    Mainka, Astrid
    Kartmann, Rene
    Brandl, Andreas
    Bruns, Heiko
    Hallam, Elizabeth
    Shaw, Jeremy
    Murphy, John
    Teoh, Wey Yang
    Aifantis, Katerina E.
    Amal, Rose
    House, Mike
    St Pierre, Tim
    Fabry, Ben
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1896 - 1905
  • [2] MAGNETIC PARTICLE SPECTROSCOPY TO MONITOR THE BEHAVIOR OF MAGNETIC NANOPARTICLES IN DIFFERENT PHYSIOLOGICAL MEDIA
    Radon, P.
    Loewa, N.
    Wiekhorst, F.
    Trahms, L.
    2015 5TH INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2015, : O22 - O22
  • [3] Optimization of Magnetic Nanoparticles for Magnetic Particle Imaging
    Ludwig, Frank
    Wawrzik, Thilo
    Yoshida, Takashi
    Gehrke, Nicole
    Briel, Andreas
    Eberbeck, Dietmar
    Schilling, Meinhard
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (11) : 3780 - 3783
  • [4] Multicore Magnetic Nanoparticles for Magnetic Particle Imaging
    Eberbeck, Dietmar
    Dennis, Cindi L.
    Huls, Natalie F.
    Krycka, Kathryn L.
    Gruettner, Cordula
    Westphal, Fritz
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (01) : 269 - 274
  • [5] Tomographic magnetic particle imaging of cancer targeted nanoparticles
    Arami, Hamed
    Teeman, Eric
    Troksa, Alyssa
    Bradshaw, Haydin
    Saatchi, Katayoun
    Tomitaka, Asahi
    Gambhir, Sanjiv Sam
    Hafeli, Urs O.
    Liggitt, Denny
    Krishnan, Kannan M.
    NANOSCALE, 2017, 9 (47) : 18723 - 18730
  • [6] Magnetic fractionation and characterization of magnetic nanoparticles for magnetic particle imaging
    Yoshida, Takashi
    Nakamura, Takuru
    Higashi, Oji
    Enpuku, Keiji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (08)
  • [7] Imaging and quantification of magnetic nanoparticles: Comparison of magnetic resonance imaging and magnetic particle imaging
    Paysen, Hendrik
    Loewa, Norbert
    Weber, Karol
    Kosch, Olaf
    Wells, James
    Schaeffter, Tobias
    Wiekhorst, Frank
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2019, 475 : 382 - 388
  • [8] Signal Separation in Magnetic Particle Imaging
    Graeser, Matthias
    Knopp, Tobias
    Sattel, Timo F.
    Gruettner, Mandy
    Buzug, Thorsten M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2483 - 2485
  • [9] Fractionated Magnetic Multicore Nanoparticles for Magnetic Particle Imaging
    Dutz, Silvio
    Eberbeck, Dietmar
    Mueller, Robert
    Zeisberger, Matthias
    MAGNETIC PARTICLE IMAGING: A NOVEL SPIO NANOPARTICLE IMAGING TECHNIQUE, 1ST EDITION, 2012, 140 : 81 - 85
  • [10] Engineering of magnetic nanoparticles as magnetic particle imaging tracers
    Lu, Chang
    Han, Linbo
    Wang, Joanna
    Wan, Jiacheng
    Song, Guosheng
    Rao, Jianghong
    CHEMICAL SOCIETY REVIEWS, 2021, 50 (14) : 8102 - 8146