In vitro evaluation of fluid reflux after flushing different types of needleless connectors

被引:12
|
作者
Elli, Stefano [1 ]
Abbruzzese, Chiara [1 ]
Cannizzo, Luigi [1 ]
Lucchini, Alberto [1 ]
机构
[1] Univ Milano Bicocca, San Gerardo Hosp, Emergency Dept & Intens Care, Monza, MB, Italy
来源
JOURNAL OF VASCULAR ACCESS | 2016年 / 17卷 / 05期
关键词
Blood; Catheter; Connector; Needleless; Occlusion; Reflux; BLOOD-STREAM INFECTION; CATHETERS; OCCLUSION; DEVICE;
D O I
10.5301/jva.5000583
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To evaluate fluid reflux, when disconnecting syringe, for different needleless connectors. Materials: Nine connectors were tested; 540 measurements were carried out. Results: The connectors tested showed very different performances, about reflux, on disconnection of the syringe used for flushing. The calculated reflux volumes are: Max Zero (R) - BD: 6.90 (+/- 2.47) mm(3); MicroClave Clear (R) - ICU Medical: 6.14 (+/- 1.46) mm(3); Bionecteur (R) - Vygon: 1.24(+/- 0.73) mm(3); Neutron (R)-ICU Medical: 0.12 (+/- 0.15) mm(3); SmartSite (R) Carefusion: 33.51 (+/- 11.50) mm(3); Safe Plus (R)-Cremascoli: 23.54 (+/- 3.56) mm(3); NeutraClear (R) - Cair: 9.36 (+/- 1.87) mm(3); NeutroX (R) - Cair: 0.33 (+/- 0.31) mm(3); Dasa (R) BTC: 2.38 (+/- 1.67) mm(3). Differences between investigated devices were statistically significant (p<0.001). Discussion: It is difficult to establish the best quality-price ratio for needleless connectors. It is important to consider several variable factors: continuous or discontinuous infusion, catheter type, usage environment and caliber of catheter used. It would therefore be useful to have an indication of the intraluminal space potentially affected by blood reflux in relation to a specific device. Conclusions: Needleless connector is one of the main factors involved in keeping catheter patency. It is important to perform the best choice among the connectors available. An empirical reflux measurement, relative to the needleless connector and the catheter in use, can be obtained using an 18G cannula.
引用
下载
收藏
页码:429 / 434
页数:6
相关论文
共 50 条
  • [41] Evaluation of pH stability in different types of heat-treated fluid and manufactured milk products during refrigerated storage
    Maduko, C. O.
    Shewfelt, R.
    Frank, J.
    Park, Y. W.
    JOURNAL OF DAIRY SCIENCE, 2004, 87 : 232 - 232
  • [42] Evaluation of Fluid Absorbency of Retraction Cords after Immersing in Two Retraction Medicaments - An In-vitro Study
    Vishnubhotla, Gautam
    Basapogu, Sreeramulu
    Karnati, Rajeev Kumar Reddy
    Dasari, Pradeep Prabhu
    Thommandru, Mani Victor
    Bethu, Mohana Bindu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (11) : ZC19 - ZC22
  • [43] Comparative evaluation of three types of denture base materials with saliva substitute before and after thermocycling: An in vitro study
    Jadhav, Varunraj
    Deshpande, Saee
    Radke, Usha
    Mahale, Hienna
    Patil, Pravinkumar G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (04): : 590 - 594
  • [44] An Evaluation of the Tensile Strength of Polyglactin Sutures After Immersion in Different Herbal Mouthwashes: An In Vitro Study
    Ojastha, B. L.
    Jeevitha, M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [45] In vitro evaluation of surface roughness of titanium abutments after air polishing with different abrasive powders
    Roberto, Pedro Francisco Almeida
    Luis, Henrique Soares
    Oliveira, Sofia Arantes
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2024,
  • [46] Evaluation of the Effect of Different Abutment Materials on the Final Color of the Restoration After Aging: An In Vitro Study
    Tuerksayar, Almira Ada Diken
    Bulut, Ali Can
    Atsu, Saadet Saglam
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (05) : 676 - 683
  • [47] In vitro evaluation of wear resistance, microhardness and superficial roughness of different fissure sealants after aging
    Akcay, Hulya Cerci
    Aktoren, Oya
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2024, 48 (01) : 32 - 40
  • [48] In vitro evaluation of equine embryo viability after 6 or 24 h of cooling in different media
    Panzani, D.
    Sabatini, C.
    Rota, A.
    Camillo, F.
    REPRODUCTION IN DOMESTIC ANIMALS, 2012, 47 : 436 - 436
  • [49] In Vitro Radiological Evaluation of Different Types of Chimney Stents Using a Silicon Flow Model with Adjustable Physiological Simulating Conditions
    Taneva, Gergana T.
    Usai, Marco, V
    Pitoulias, Georgios A.
    Donas, Konstantinos P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 66 (02) : 270 - 277
  • [50] The evaluation of two different types of sequential culture media systems for human in vitro fertilization using sister oocytes.
    Chesmore, J
    Lambert, H
    Lopez, A
    Vu, K