Intra-Aortic Balloon Pump Simulating Thoracic Aortic Dissection

被引:0
|
作者
Siegel, Yoel [1 ]
Munera, Felipe [1 ]
Durso, Anthony M. [1 ]
Roth, Patrick [1 ]
机构
[1] Univ Miami, Jackson Mem Hosp, Miller Sch Med, Dept Radiol, Miami, FL 33136 USA
关键词
aortic dissection; intra-aortic balloon pump; CARDIOGENIC-SHOCK; COUNTERPULSATION; CT;
D O I
10.1097/RCT.0000000000000728
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a 70-year-old woman who had an intra-aortic balloon pump (IABP) in its deflated state in the aorta during a computed tomography angiogram scan. The scan was performed to assess for aortic dissection. The deflated IABP created a curvilinear filling defect in the aortic lumen that suggested an intimal flap. Herein, we described the finding and suggest key features that can help distinguish between this intra-aortic device and a true dissection. This distinction between the device and aortic dissection is not only important because of the potential pitfall of a false positive diagnosis but also because an IABP itself can lead to an aortic dissection and therefore its computed tomography features should be recognized in both its inflated and deflated state.
引用
收藏
页码:630 / 631
页数:2
相关论文
共 50 条
  • [31] Acute thoracic aortic thrombosis after intra-aortic balloon pumping
    Aggeli, Constadina
    Barberis, Vassilis I.
    Vlachopoulos, Charalambos
    Tsiamis, Eleftherios
    Stefanadis, Christodoulos
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (02): : 175 - 176
  • [32] Endovascular repair of aortic perforation and type B aortic dissection after axillary intra-aortic balloon pump insertion
    Twohig, Kelly
    Williamson, Ashley J.
    Milner, Ross
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2021, 7 (04): : 617 - 620
  • [33] Intra-aortic balloon pump microperforation resulting in balloon entrapment
    Warrillow, S. J.
    Fealy, N. G.
    Houston, S. A.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (06) : 916 - 917
  • [34] DISSECTION OF AORTA COMPLICATING INTRA-AORTIC BALLOON COUNTERPULSATION
    BIDDLE, TL
    STEWART, S
    STUARD, ID
    AMERICAN HEART JOURNAL, 1976, 92 (06) : 781 - 784
  • [35] INTRA-AORTIC BALLOON-PUMP RUPTURE AND ENTRAPMENT
    BRODELL, GK
    TUZCU, EM
    WEISS, SJ
    SIMPFENDORFER, C
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 1989, 56 (07) : 740 - 742
  • [36] Intra-Aortic Balloon Pump (IABP) in cardiogenic shock
    Fuernau, Georg
    Thiele, Holger
    CURRENT OPINION IN CRITICAL CARE, 2013, 19 (05) : 404 - 409
  • [37] COMPLICATIONS ASSOCIATED WITH USE OF THE INTRA-AORTIC BALLOON PUMP
    GOLDMAN, BS
    HILL, TJ
    ROSENTHAL, GA
    SCULLY, HE
    WEISEL, RD
    BAIRD, RJ
    CANADIAN JOURNAL OF SURGERY, 1982, 25 (02) : 153 - 156
  • [38] Intra-aortic balloon pump: is the technique really outdated?
    Akodad, Mariama
    Delmas, Clement
    Bonello, Laurent
    Duflos, Claire
    Roubille, Francois
    ESC HEART FAILURE, 2020, 7 (03): : 1025 - 1030
  • [39] Association of thrombocytopenia and use of intra-aortic balloon pump
    Vonderheide, RH
    Kuter, DJ
    Thadhani, R
    CIRCULATION, 1996, 94 (08) : 4297 - 4297
  • [40] A rare complication of intra-aortic balloon pump placement
    Varadarajan, B
    Karski, J
    Vegas, A
    Heinrich, L
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (02) : 259 - 260