Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

被引:23
|
作者
Gao, Jie [1 ]
Zhang, Min [2 ]
Zhou, Liqin [1 ]
Yang, Xing [1 ]
Wu, Haigui [1 ]
Zhang, Jianfang [1 ]
Wu, Feng [1 ]
机构
[1] Guangzhou Med Univ, Dept Resp Med, Peoples Hosp 3, 1 Xuebei Ave, Huizhou 516002, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Internal Med Cardiovasc Dept, Peoples Hosp 3, Huizhou, Peoples R China
关键词
fractional exhaled nitric oxide; eosinophils in induced sputum; blood eosinophil percentage; chronic obstructive pulmonary disease; AIRWAY EOSINOPHILIA; ASTHMA;
D O I
10.2147/COPD.S134998
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (>= 2.5%)/FeNO levels (>= 32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (rho=0.221, P=0.005) and blood eosinophilic percentage (rho=0.399, P < 0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P. 0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity = 61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [41] Both fractional exhaled nitric oxide and sputum eosinophil were associated with uncontrolled asthma
    Gao, Jie
    Chen, Zhaocheng
    Jie, Xiang
    Ye, Ruihua
    Wu, Feng
    JOURNAL OF ASTHMA AND ALLERGY, 2018, 11 : 73 - 79
  • [42] Relationship between fractional exhaled nitric oxide and nasal nitric oxide in airways disease
    Williamson, Peter A.
    Vaidyanathan, Sriram
    Clearie, Karine
    Stewart, Munro
    Lipworth, Brian J.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2010, 105 (02) : 162 - 167
  • [43] High fractional exhaled nitric oxide and sputum eosinophils are associated with an increased risk of future virus-induced exacerbations: A prospective cohort study
    Bjerregaard, A.
    Laing, I. A.
    Backer, V.
    Sverrild, A.
    Khoo, S. -K.
    Chidlow, G.
    Sikazwe, C.
    Smith, D. W.
    Le Souef, P.
    Porsbjerg, C.
    CLINICAL AND EXPERIMENTAL ALLERGY, 2017, 47 (08): : 1007 - 1013
  • [44] Association between Fractional Exhaled Nitric Oxide and Asthma Control
    Prottasan, P.
    Maneechotesuwan, K.
    Vichyanond, P.
    Jirapongsananuruk, O.
    Pacharn, P.
    Visitsunthorn, N.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2011, 127 (02) : AB9 - AB9
  • [45] Blood Eosinophils and Exhaled Nitric Oxide: Surrogate Biomarkers of Airway Eosinophilia in Stable COPD and Exacerbation
    Antus, Balazs
    Barta, Imre
    BIOMEDICINES, 2022, 10 (09)
  • [46] Predictive Value of Exhaled Nitric Oxide and Blood Eosinophil Count in the Assessment of Airway Eosinophilia in COPD
    Antus, Balazs
    Paska, Csilla
    Barta, Imre
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2020, 15 : 2025 - 2035
  • [47] Fractional exhaled nitric oxide in bronchiectasis
    Cho, Young-Jae
    Lim, Hyo-Jeong
    Park, Jong Sun
    Lee, Sei Won
    Lee, Jae Ho
    Lee, Choon-Taek
    Yoon, Ho Il
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [48] Correlation of eosinophil counts in induced sputum and fractional concentration of exhaled nitric oxide and lung functions in patients with mild to moderate asthma
    WANG Wen
    HUANG Ke-wu
    WU Bao-mei
    WANG Yan-jun
    WANG Chen
    中华医学杂志(英文版), 2012, (17) : 3157 - 3160
  • [49] THE CORRELATION OF EOSINOPHIL COUNTS IN INDUCED SPUTUM AND FRACTIONAL CONCENTRATION OF EXHALED NITRIC OXIDE AND LUNG FUNCTIONS IN PATIENT WITH MILD TO MODERATE ASTHMA
    Wang, W.
    Huang, K-W
    Wang, C.
    RESPIROLOGY, 2011, 16 : 200 - 201
  • [50] Correlation of eosinophil counts in induced sputum and fractional concentration of exhaled nitric oxide and lung functions in patients with mild to moderate asthma
    Wang Wen
    Huang Ke-wu
    Wu Bao-mei
    Wang Yan-jun
    Wang Chen
    CHINESE MEDICAL JOURNAL, 2012, 125 (17) : 3157 - 3160