Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

被引:23
|
作者
Gao, Jie [1 ]
Zhang, Min [2 ]
Zhou, Liqin [1 ]
Yang, Xing [1 ]
Wu, Haigui [1 ]
Zhang, Jianfang [1 ]
Wu, Feng [1 ]
机构
[1] Guangzhou Med Univ, Dept Resp Med, Peoples Hosp 3, 1 Xuebei Ave, Huizhou 516002, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Internal Med Cardiovasc Dept, Peoples Hosp 3, Huizhou, Peoples R China
关键词
fractional exhaled nitric oxide; eosinophils in induced sputum; blood eosinophil percentage; chronic obstructive pulmonary disease; AIRWAY EOSINOPHILIA; ASTHMA;
D O I
10.2147/COPD.S134998
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (>= 2.5%)/FeNO levels (>= 32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (rho=0.221, P=0.005) and blood eosinophilic percentage (rho=0.399, P < 0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P. 0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity = 61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [1] Predicting Sputum Eosinophilia in Exacerbations of COPD Using Exhaled Nitric Oxide
    Soter, Szabolcs
    Barta, Imre
    Antus, Balazs
    INFLAMMATION, 2013, 36 (05) : 1178 - 1185
  • [2] Predicting Sputum Eosinophilia in Exacerbations of COPD Using Exhaled Nitric Oxide
    Szabolcs Soter
    Imre Barta
    Balazs Antus
    Inflammation, 2013, 36 : 1178 - 1185
  • [3] Correlation Between Sputum Eosinophilia And Exhaled Nitric Oxide
    Lee, J.
    Paeng, J. -W.
    Choi, D. -C.
    Lee, B. -J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [4] Variability of the fractional exhaled nitric oxide to predict acute exacerbations in COPD
    Papakonstantinou, E.
    Schumann, M. D.
    Kostikas, K.
    Grieze, L.
    Tamm, M.
    Stolz, D.
    PNEUMOLOGIE, 2022, 76 : S64 - S64
  • [5] Fractional Exhaled Nitric Oxide: Comparison Between Portable Devices and Correlation With Sputum Eosinophils
    Yune, Sehyo
    Lee, Jin-Young
    Choi, Dong-Chull
    Lee, Byung-Jae
    ALLERGY ASTHMA & IMMUNOLOGY RESEARCH, 2015, 7 (04) : 404 - 408
  • [6] Fractional Exhaled Nitric Oxide: Comparison Between Portable Devices And Correlation With Sputum Eosinophils
    Choi, D. -C.
    Yune, S.
    Lee, J. -Y.
    Lee, B. -J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [7] Correlation of Fractional Exhaled Nitric Oxide Level With Severity of COPD
    See, Johnson
    Bayot, Rommel
    CHEST, 2017, 152 (04) : 804A - 804A
  • [8] Exhaled nitric oxide in stable COPD and exacerbations
    Bhowmik, A
    Seemungal, T
    Roland, M
    Wedzicha, JA
    THORAX, 1999, 54 : A72 - A72
  • [9] Variability of fractional exhaled nitric oxide is associated with the risk and aetiology of COPD exacerbations
    Schumann, Desiree M. M.
    Papakonstantinou, Eleni
    Kostikas, Konstantinos
    Grize, Leticia
    Tamm, Michael
    Stolz, Daiana
    RESPIROLOGY, 2023, 28 (05) : 445 - 454
  • [10] Variability of fractional exhaled nitric oxide may predict acute exacerbations in COPD
    Papakonstantinou, E.
    Schumann, D.
    Kostikas, K.
    Grize, L.
    Tamm, M.
    Stolz, D.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60