Occupant evacuation and orientation problems in large halls - An exhibition building case study

被引:0
|
作者
Horasan, MBN [1 ]
机构
[1] Sci Serv Lab, Port Melbourne, Vic 3207, Australia
关键词
D O I
10.1002/(SICI)1099-1018(199911/12)23:6<369::AID-FAM713>3.0.CO;2-T
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A major exhibition building in Melbourne, Australia, faced a dilemma regarding the signage installed in the building according to the deemed to satisfy provisions of the Building Codes. The main hall is 450 m long and 80 m wide when all partitions are opened. Exit doors are located at the perimeter of the building and there are standard self illuminating exit signs above doors. When the hall is empty all doors and exit signs are clearly visible, however, during an exhibition when all stands, cubicles, structures, signs and stages are installed most of the exit signs become obscured. The occupants of the building, which can be as many as 10000 people at any one time, could face the problem of becoming disoriented in the case of a fire related emergency due to factors such as colour and light noise and lack of immediate access to exit signage. As a result they fail to respond and behave as assumed in the emergency evacuation plan. The study discussed in this paper investigates alternative exit signage methods in order to assist the occupants to respond quickly to warning systems and initiate evacuation as desired and planned by the management of the Centre Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 50 条
  • [21] Dynamic risk assessment of emergency evacuation in large public buildings: A case study
    Li, JiaFeng
    Hu, YuLing
    Zou, WeiGuang
    INTERNATIONAL JOURNAL OF DISASTER RISK REDUCTION, 2023, 91
  • [22] Improving accuracy in building energy simulation via evaluating occupant behaviors: A case study in Hong Kong
    Yu, Cong
    Du, Jia
    Pan, Wei
    ENERGY AND BUILDINGS, 2019, 202
  • [23] A Simultaneous Usage Ratio Based on Occupant Behavior: A Case Study of Intermittent Heating in an Apartment Building in Japan
    Kikuta, Koki
    Abe, Yuhei
    BUILDINGS, 2024, 14 (06)
  • [24] Full cycle personnel simulation from entry to evacuation of multi-story building -An office building case Study
    Zhu, Keqin
    Hu, Yuling
    Xu, Rui
    Liao, Li
    Xu, Nannan
    2023 35TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC, 2023, : 2135 - 2139
  • [25] Comparative study of Chinese and Japanese evacuation safety requirements: A case study on an actual office building project in Shanghai
    Visiting Research Associate, RISE, Waseda University, Japan
    不详
    AIJ J. Technol. Des., 27 (169-172):
  • [26] Modeling of occupant energy consumption behavior based on human dynamics theory: A case study of a government office building
    Zhou, Xuan
    Mei, Yukun
    Liang, Liequan
    Mo, Haohua
    Yan, Junwei
    Pan, Dongmei
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [27] The effect of occupant distribution on energy consumption and COVID-19 infection in buildings: A case study of university building
    Mokhtari, Reza
    Jahangir, Mohammad Hossein
    BUILDING AND ENVIRONMENT, 2021, 190
  • [28] IMPACT OF ORIENTATION AND BUILDING ENVELOPE CHARACTERISTICS ON ENERGY CONSUMPTION Case Study of Office Building in City of Nis
    Vasov, Miomir S.
    Stevanovic, Jelena N.
    Bogdanovic, Veliborka B.
    Ignjatovic, Marko G.
    Randjelovic, Dusan J.
    THERMAL SCIENCE, 2018, 22 : S1499 - S1509
  • [29] The impact of building enclosure type and building orientation on indoor thermal comfort ---A case study of Kashgar in China
    Dai, Jialu
    Wang, Jinming
    Bart, Dewancker
    Gao, Weijun
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [30] How to ensure occupant comfort and satisfaction through deep building retrofit? Lessons from a Danish case study
    Sarran, Lucile
    Hviid, Christian Anker
    Rode, Carsten
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (07) : 663 - 677