Occupant evacuation and orientation problems in large halls - An exhibition building case study

被引:0
|
作者
Horasan, MBN [1 ]
机构
[1] Sci Serv Lab, Port Melbourne, Vic 3207, Australia
关键词
D O I
10.1002/(SICI)1099-1018(199911/12)23:6<369::AID-FAM713>3.0.CO;2-T
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A major exhibition building in Melbourne, Australia, faced a dilemma regarding the signage installed in the building according to the deemed to satisfy provisions of the Building Codes. The main hall is 450 m long and 80 m wide when all partitions are opened. Exit doors are located at the perimeter of the building and there are standard self illuminating exit signs above doors. When the hall is empty all doors and exit signs are clearly visible, however, during an exhibition when all stands, cubicles, structures, signs and stages are installed most of the exit signs become obscured. The occupants of the building, which can be as many as 10000 people at any one time, could face the problem of becoming disoriented in the case of a fire related emergency due to factors such as colour and light noise and lack of immediate access to exit signage. As a result they fail to respond and behave as assumed in the emergency evacuation plan. The study discussed in this paper investigates alternative exit signage methods in order to assist the occupants to respond quickly to warning systems and initiate evacuation as desired and planned by the management of the Centre Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 50 条
  • [1] Experimental study of the impact of personality traits on occupant exit choice during building evacuation
    Zhan, Xin
    Yang, Lizhong
    Zhu, Kongjin
    Kong, Xiaoming
    Rao, Ping
    Zhang, Taolin
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 548 - 553
  • [2] Optimizing Solar Heating for Thangka Exhibition Halls: A Case Study in Malkang Cultural Village
    Han, Wenyang
    Bai, Yan
    Du, Miao
    Tao, Yujie
    Zhang, Yin
    Yang, Qianru
    ENERGIES, 2024, 17 (09)
  • [3] Embodied energy of building materials and green building rating systems-A case study for industrial halls
    Lee, Bruno
    Trcka, Marija
    Hensen, Jan L. M.
    SUSTAINABLE CITIES AND SOCIETY, 2011, 1 (02): : 67 - 71
  • [4] Air diffusion system design in large assembly halls. Case study of the Congress of Deputies parliament building, Madrid, Spain
    O'Donohoe, Paul G.
    Galvez-Huerta, Miguel A.
    Gil-Lopez, Tomas
    Dieguez-Elizondo, Pedro M.
    Castejon-Navas, Juan
    BUILDING AND ENVIRONMENT, 2019, 164
  • [5] Study on Simulation Software of Personnel Safety Evacuation in Large Public Building Fire
    Yun, Wang
    APPLIED INFORMATICS AND COMMUNICATION, PT 5, 2011, 228 : 116 - 123
  • [6] Study on Simulation Software of Personnel Safety Evacuation in Large Public Building Fire
    Wang Yun
    2010 THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION (PACIIA2010), VOL V, 2010, : 75 - 78
  • [7] Agent-Based Simulation of Evacuation: An Office Building Case Study
    Lin, Yiqing
    Fedchenia, Igor
    LaBarre, Bob
    Tomastik, Robert
    PEDESTRIAN AND EVACUATION DYNAMICS 2008, 2010, : 347 - +
  • [8] Wistfully Waiting No More: An Open Source, Exhibition Building Case Study
    Alexander, John A.
    DESIDOC JOURNAL OF LIBRARY & INFORMATION TECHNOLOGY, 2013, 33 (03): : 199 - 207
  • [9] Towards occupant-centric simulation-aided building design: a case study
    Abuimara, Tareq
    O'Brien, William
    Gunay, Burak
    Carrizo, Juan Sebastian
    BUILDING RESEARCH AND INFORMATION, 2019, 47 (08): : 866 - 882
  • [10] A Case Study on Moisture Problems and Building Defects
    Othman, Nur Liyana
    Jaafar, Mastura
    Harun, Wan Mariah Wan
    Ibrahim, Fuziah
    ASIAN CONFERENCE ON ENVIRONMENT-BEHAVIOUR STUDIES (ACE-BS 2014 SEOUL), 2015, 170 : 27 - 36