Comparison and modification of two cerebral protection devices used for carotid angioplasty:: In vitro experiment

被引:19
|
作者
Müller-Hülsbeck, S
Grimm, J
Liess, C
Hedderich, J
Bergmeyer, M
Heller, M
机构
[1] Univ Hosp Kiel, Dept Radiol, D-24105 Kiel, Germany
[2] Univ Hosp Kiel, Dept Phys Med, D-24105 Kiel, Germany
[3] Univ Hosp Kiel, Dept Med Stat, D-24105 Kiel, Germany
关键词
carotid arteries; stenosis or obstruction; interventional procedures; complications; experimental studies;
D O I
10.1148/radiol.2251011008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effectiveness of two basic cerebral protection devices designed for carotid angioplasty with and without additional aspiration techniques was compared in an in vitro model. During carotid angioplasty, embolization was simulated by injecting polyvinyl alcohol particles of different sizes into the model system: None of the tested devices, all of,which were positioned in the internal carotid artery, was able to completely prevent embolization. In the internal carotid artery, the rate of particle capture did not vary among protection devices. However, embolization into the external carotid artery was more frequent with use of the GuideWire, as compared with that with use of the Angioguard. (C) RSNA, 2002.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [21] Role of Cerebral Protection In Carotid Angioplasty And Stenting
    Karanam, L. S. P.
    Ahlman, P.
    Dev, B.
    Joseph, S.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2010, 4 (01) : 1999 - 2004
  • [22] Carotid angioplasty with cerebral protection and endovascular prothesis
    SolerSingla, L
    Guimaraens, L
    Matali, A
    Balaguer, E
    Castellanos, C
    Miquel, L
    REVISTA DE NEUROLOGIA, 1997, 25 (138) : 287 - 290
  • [23] Cerebral protection during carotid angioplasty - Reply
    Kachel, R
    JOURNAL OF ENDOVASCULAR SURGERY, 1996, 3 (04): : 485 - 486
  • [24] In vitro performance assessment of cerebral protection devices in carotid artery stenting
    Finol, E
    Gaspard, S
    Wholey, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 146H - 146H
  • [25] Cerebral protection devices for use during carotid artery angioplasty with stenting: A health technology assessment
    Public Health Sciences, University of Alberta, 13-103 Clinical Sciences Building, Edmonton, Alta. T6G 2G3, Canada
    不详
    Int. J. Technol. Assess. Health Care, 2006, 1 (119-129):
  • [26] Cerebral protection devices for use during carotid artery angioplasty with stenting: A health technology assessment
    Menon, D
    Stafinski, T
    INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2006, 22 (01) : 119 - 129
  • [27] Early outcome of carotid angioplasty and stenting with and without cerebral protection devices -: A systematic review of the literature
    Kastrup, A
    Gröschel, K
    Krapf, H
    Brehm, BR
    Dichgans, J
    Schulz, JB
    STROKE, 2003, 34 (03) : 813 - 819
  • [28] Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
    Dhillon, Ashwat S.
    Li, Sisi
    Lewinger, Juan Pablo
    Shavelle, David M.
    Matthews, Ray V.
    Clavijo, Leonardo C.
    Weaver, Fred A.
    Garg, Parveen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (04) : 743 - 749
  • [29] Carotid angioplasty assisted with stenting under cerebral protection
    Ferrario, A
    Miranda, C
    Musacchio, A
    Vila, F
    Pabón, B
    Lylyk, P
    JOURNAL OF NEUROSURGERY, 2004, 100 (01) : A184 - A184
  • [30] Cerebral protection devices for carotid artery stenting
    Rodriguez, HE
    Eskandari, MK
    TRENDS IN VASCULAR SURGERY, 2003, : 99 - 107