X-ray pulse selector with 2 ns lock-in phase setting and stability

被引:0
|
作者
Lindenau, B [1 ]
Räbiger, J [1 ]
Polachowski, S [1 ]
Fremerey, JK [1 ]
机构
[1] Forschungszentrum Julich, D-52425 Julich, Germany
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Selector devices, which are based on magnetically suspended, high speed triangular shutter rotors, have been designed and built in cooperation with ESRF [1], APS [2], and recently Spring-8 [3] for time resolved studies with solated x-ray pulses at white beam lines. The x-ray pulse selection is accomplished by means of a beam channel along one of the edges of the triangular rotor, which opens once per revolution. Entrance and exit apertures of the channel can be designed wedge shaped for variable tuning of the channel height between 0.1 mm to 0.9 mm. At the 1 kHz maximum operation frequency of a 220 mm diameter disk with 190 mm channel length, the practicable open times of the channel are demonstrated to range down to 200 ns. The selector drive electronics is directly coupled to the storage ring RF clock for rotational phase control. It allows for continuous selector operation in phase locked mode to the temporal pulse structure of the synchrotron at 2 ns RMS stability. The phase angle between the pulse transmission period and the synchrotron bunch sequence can be adjusted with similar precision for X-ray pulse selection according to the expenmental needs. [1] ID09, Michael Wulff; [2] BioCARS 14-BM, Reinhard Pahl; [3] BL40-XU, Shin-ichi Adachi.
引用
收藏
页码:1019 / 1022
页数:4
相关论文
共 50 条
  • [21] Comparison of quantitative defect characterization using pulse-phase and lock-in thermography: erratum
    Maierhofer, Christiane
    Roellig, Mathias
    Krankenhagen, Rainer
    Myrach, Philipp
    APPLIED OPTICS, 2024, 63 (31) : 8295 - 8296
  • [22] Photon echo using imperfect x-ray pulse with phase fluctuation
    Chen, Jin-Fu
    Dong, Hui
    Sun, Chang-Pu
    PHYSICA SCRIPTA, 2019, 94 (10)
  • [23] Thermal Stability of α Phase of Titanium by Using X-Ray Diffraction
    Jafari, Mahmoud
    Vaezzadeh, Mehdi
    Noroozizadeh, Sogand
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2010, 41A (13): : 3287 - 3290
  • [24] Thermal Stability of α Phase of Titanium by Using X-Ray Diffraction
    Mahmoud Jafari
    Mehdi Vaezzadeh
    Sogand Noroozizadeh
    Metallurgical and Materials Transactions A, 2010, 41 : 3287 - 3290
  • [25] Performance Bounds for the Pulse-Phase Estimation of X-Ray Pulsars
    Nguyen Duy Tran
    Renaux, Alexandre
    Boyer, Remy
    Marcos, Sylvie
    Larzabal, Pascal
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2014, 50 (01) : 790 - 797
  • [26] Dips in the X-ray pulse profiles of accretion powered X-ray pulsars
    Bulik, T
    Cemeljic, M
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1999, 38 (1-6) : 49 - 52
  • [27] Application of the X-ray picosecond framing camera in intense X-ray pulse
    Southwest Inst of Nuclear Physics, and Chemistry, Chengdu, China
    Guangxue Xuebao, 12 (1738-1740):
  • [28] PULSE LENGTH IN AN X-RAY DIODE
    ZLATIN, NA
    PUGACHEV, GS
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1971, 15 (10): : 1754 - &
  • [29] PULSE X-RAY ANNEALING OF DEFECTS
    KUMAKHOV, MA
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 15 (17): : 91 - 92
  • [30] PULSE NEUTRON X-RAY TUBE
    BESSARABSKII, YG
    DEMIDOV, FP
    OVSYANNIKOV, SB
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1975, (01): : 211 - 213