Improving surface plasmon resonance sensor performance using critical angle compensation

被引:7
|
作者
Chinowsky, TM [1 ]
Strong, A [1 ]
Bartholomew, DU [1 ]
Jorgensen-Soelberg, S [1 ]
Notides, T [1 ]
Furlong, CE [1 ]
Yee, SS [1 ]
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
来源
关键词
surface plasmon resonance; critical angle refractometry; temperature compensation;
D O I
10.1117/12.370277
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The sensing range of surface plasmon resonance (SPR) refractometry is greater than the thickness of most thin films of interest. Therefore, an SPR sensor will also respond to changes in the refractive index (RI) of the bulk analyte adjacent to the thin film, caused for instance by variations in analyte composition or temperature. These changes in bulk RI degrade the quality of SPR sensing data. One solution to this problem is simultaneously to measure both the SPR response and the bulk RI of the analyte and correct the SPR response for bulk RI variations. We present a simple implementation of this approach which uses critical angle refractometrp. Our sensor is based on Texas Instrunents' Spreeta(R) SPR sensor. The gold is removed from the portion of the sensor surface which corresponds to angles less than the critical angle. The modified sensor delivers a composite spectrum which may be used for measurements of both the critical angle edge and the SPR dip. Theory of critical angle compensation is presented, and calibration and data analysis issues are outlined. Critical angle compensation for temperature and concentration induced bulk RI changes is demonstrated in detergent adsorption and antibody binding experiments.
引用
收藏
页码:104 / 113
页数:10
相关论文
共 50 条
  • [1] Triangular resonator with surface plasmon resonance around the critical angle
    Kim, Doo Gun
    Oh, Geum-Yoon
    Kim, Seon Hoon
    Ki, Hyun Chul
    Kim, Hyo Jin
    Kim, Hwe Jong
    Kim, Jae Hun
    Chung, Tae Kyung
    Choi, Young-Wan
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (07)
  • [2] Considerations for improving the performance of surface plasmon resonance biosensors
    Zhang Yingying
    Lai Jiancheng
    Wang Chunyong
    Li Zhenhua
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 583 - +
  • [3] Surface plasmon resonance sensor based on polarization interferometry and angle modulation
    Sun, ZL
    He, YH
    Guo, JH
    APPLIED OPTICS, 2006, 45 (13) : 3071 - 3076
  • [4] Review of Surface Plasmon Resonance and Localized Surface Plasmon Resonance Sensor
    Chen, Yong
    Ming, Hai
    PHOTONIC SENSORS, 2012, 2 (01) : 37 - 49
  • [5] Review of surface plasmon resonance and localized surface plasmon resonance sensor
    Yong Chen
    Hai Ming
    Photonic Sensors, 2012, 2 (1) : 37 - 49
  • [6] Surface plasmon resonance sensor
    Han, Won-Sik
    Jung, Kyu-jin
    Lee, Sang-Won
    Hong, Suk-Young
    Lee, Young-Hoon
    Hong, Tae-Kee
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (01): : 9 - 17
  • [7] Influence of Dielectric Coating on Performance of Surface Plasmon Resonance Sensor
    J. B. Maurya
    Y. K. Prajapati
    Plasmonics, 2017, 12 : 1121 - 1130
  • [8] Influence of adhesion layer on performance of surface plasmon resonance sensor
    Maurya, Jitendra Bahadur
    Prajapati, Yogendra Kumar
    IET OPTOELECTRONICS, 2018, 12 (04) : 168 - 175
  • [9] Double-incident Angle Method for the Improvement of Angle Scan Surface Plasmon Resonance Sensor
    Luo, Wei
    Hu, Zelin
    Liu, Jiarui
    Sun, Fenglong
    Li, Hualong
    Chen, Lei
    Gao, Huiyi
    Li, Miao
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, MACHINERY AND ENERGY ENGINEERING (MSMEE 2017), 2017, 123 : 1503 - 1507
  • [10] Influence of Dielectric Coating on Performance of Surface Plasmon Resonance Sensor
    Maurya, J. B.
    Prajapati, Y. K.
    PLASMONICS, 2017, 12 (04) : 1121 - 1130