Dilatometer used for Measurements in Building Materials Testing

被引:0
|
作者
Christov, Ivan [2 ]
Pavlendova, Gabriela [1 ]
Veselsky, Juraj [1 ]
机构
[1] SlovakUniv Technol, Fac CE, Dept Phys, Bratislava 81368, Slovakia
[2] Metrodat Sro, Beblaveho 8, Bratislava 81101, Slovakia
关键词
thermal expansion; moisture expansion; dilatometer;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dimensional change of building materials as a function of temperature and moisture is important characteristic that needs to be monitored. In cooperation of the Department of Physics at STU and company METRODAT the dilatometer for measurement of thermal and moisture expansion coefficient was produced. Measuring systems using LVDT sensor located into ZERODUR closed loop measurement frame provide the maximum precision, repeatability and accuracy in temperature range from -15 degrees C to 105 degrees C and from 10 % to 100 % relative air humidity. The sample holder is made from stainless steel and allows to work with samples from 10 mm to 160 mm of initial lengths. The measurement process is PC controlled.
引用
收藏
页码:180 / 184
页数:5
相关论文
共 50 条
  • [21] Environmental Analysis of Materials Used for Building Foundation
    Ondova, Marcela
    Estokova, Adriana
    PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 601 - 606
  • [22] PENETRATION OF WATER IN SOME MATERIALS USED IN BUILDING
    TITEICA, R
    STUDII SI CERCETARI DE FIZICA, 1979, 31 (07): : 791 - 794
  • [23] Chemical composition of building materials used in Turkey
    Cevik, U.
    Damla, N.
    Van Grieken, R.
    Akpinar, M. Vefa
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (04) : 1546 - 1552
  • [24] Natural radioactivity of granites used as building materials
    Pavlidou, S.
    Koroneos, A.
    Papastefanou, C.
    Christofides, G.
    Stoulos, S.
    Vavelides, M.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2006, 89 (01) : 48 - 60
  • [25] A HETERODYNE LASER INTERFEROMETER FOR DILATOMETER MEASUREMENTS
    Kulesh, V. P.
    Moskalik, L. M.
    Sharov, A. A.
    MEASUREMENT TECHNIQUES, 2009, 52 (12) : 1319 - 1327
  • [26] DILATOMETER TESTING IN HIGHLY OVERCONSOLIDATED SOILS
    BOGHRAT, A
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1987, 113 (05): : 516 - 519
  • [27] Data on comparison between FLEC and CLIMPAQ methods used for fast sorption measurements of VOCs on building materials
    Rizk, Malak
    Verriele, Marie
    Mendez, Maxence
    Blond, Nadege
    Dusanter, Sebastien
    Schoemaecker, Coralie
    Blondeau, Patrice
    Le Calve, Stephane
    Locoge, Nadine
    DATA IN BRIEF, 2016, 7 : 518 - 523
  • [28] A contactless CCD dilatometer for foil materials
    Wang, H
    Zhang, YY
    He, GH
    Wang, BQ
    Zhou, BL
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1999, 20 (02) : 743 - 753
  • [29] NONLINEARITY TESTING OF EQUIPMENT USED IN TEMPERATURE MEASUREMENTS
    Podgornik, Tadej
    Batagelj, Valentin
    Bojkovski, Jovan
    Drnovsek, Janko
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 815 - 819
  • [30] PHOTORESISTOR DILATOMETER FOR INVESTIGATION OF POLYMER MATERIALS
    KORCHINSKII, NA
    GRINEVA, LV