Fabrication Localized Surface Plasmon Resonance sensor chip of gold nanoparticles and detection lipase-osmolytes interaction

被引:14
|
作者
Ghodselahi, T. [1 ,2 ]
Hoornam, S. [1 ,2 ,3 ]
Vesaghi, M. A. [4 ]
Ranjbar, B. [5 ]
Azizi, A. [5 ]
Mobasheri, H. [6 ,7 ]
机构
[1] Nano Mabna Iranian Inc, Tehran, Iran
[2] Inst Res Fundamental Sci, Sch Phys, Tehran, Iran
[3] Islamic Azad Univ, Cent Tehran Branch, Dept Sci, Tehran, Iran
[4] Sharif Univ Technol, Dept Phys, Tehran, Iran
[5] Tarbiat Modares Univ, Dept Biophys, Tehran, Iran
[6] Univ Tehran, Inst Biochem & Biophys, Lab Membrane Biophys, Tehran, Iran
[7] Univ Tehran, Biomat Res Inst BRC, Tehran, Iran
关键词
Localized Surface Plasmon Resonance; Sensor chip of Au NPs; RF-sputtering and RF-PECVD; Biosensor; Pseudomonas cepacia lipase; Osmolytes; SPECTROSCOPY; ABSORPTION; SORBITOL; ARRAYS; SIZE;
D O I
10.1016/j.apsusc.2014.06.095
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Co-deposition of RF-sputtering and RF-PECVD from acetylene gas and Au target were used to prepare sensor chip of gold nanoparticles (Au NPs). Deposition conditions were optimized to reach a Localized Surface Plasmon Resonance (LSPR) sensor chip of Au NPs with particle size less than 10 nm. The RF power was set at 180W and the initial gas pressure was set at 0.035 mbar. Transmission Electron Microscopy (TEM) images and Atomic Force Microscopy (AFM) data were used to investigate particles size and surface morphology of LSPR sensor chip. The Au and C content of the LSPR sensor chip of Au NPs was obtained from X-ray photoelectron spectroscopy (XPS). The hydrogenated amorphous carbon (a-C:H) thin film was used as intermediate material to immobilize Au NPs on the SiO2 substrate. The interaction between two types of osmolytes, i.e. sorbitol and trehalose, with Pseudomonas cepacia lipase (PCL) were detected by the prepared LSPR biosensor chip. The detection mechanism is based on LSPR spectroscopy in which the wavelength of absorption peak is sensitive to the refractive index of the environment of the Au NPs. This mechanism eliminates the use of a probe or immobilization of PCL on the Au NPs of LSPR sensor chip. The interaction between PCL and osmolytes can change refractive index of the mixture or solution. We found that unlike to trehalose, sorbitol interacts with the PCL. This interaction increases refractive index of the PCL and sorbitol mixture. Refractive index of PCL in the presence of different concentration of sorbitol was obtained by Mie theory modeling of LSPR peaks. This modeling stated that the present LSPR sensor chip has sensitivity as high as wavelength shift of 175 nm per refractive index. Moreover, the detection of such weakly interaction between bio-molecules cannot be achieved by other analysis. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 50 条
  • [21] Localized surface plasmon resonance-based biosensor on gold nanoparticles for Taenia solium detection
    Arcas, Ariadny S.
    Jaramillo, Lizeth
    Costa, Natalia S.
    Allil, Regina Celia S. B.
    Werneck, Marcelo M.
    APPLIED OPTICS, 2021, 60 (26) : 8137 - 8144
  • [22] Detection of Volatile Organic Compound Gas Using Localized Surface Plasmon Resonance of Gold Nanoparticles
    Nengsih, Sri
    Umar, Akrajas Ali
    Salleh, Muhamad Mat
    Yahaya, Muhammad
    SAINS MALAYSIANA, 2011, 40 (03): : 231 - 235
  • [23] Review of Surface Plasmon Resonance and Localized Surface Plasmon Resonance Sensor
    Chen, Yong
    Ming, Hai
    PHOTONIC SENSORS, 2012, 2 (01) : 37 - 49
  • [24] Review of surface plasmon resonance and localized surface plasmon resonance sensor
    Yong Chen
    Hai Ming
    Photonic Sensors, 2012, 2 (1) : 37 - 49
  • [25] Limitation of a localized surface plasmon resonance sensor for Salmonella detection
    Fu, Junxue
    Park, Bosoon
    Zhao, Yiping
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01): : 276 - 283
  • [26] Gold nanoparticles as a localized surface plasmon resonance based chemical sensor for on-site colorimetric detection of arsenic in water samples
    Shrivas, Kamlesh
    Shankar, Ravi
    Dewangan, Khemchand
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 1376 - 1383
  • [27] Colorimetric determination of nabumetone based on localized surface plasmon resonance of functionalized gold nanoparticles as a chemical sensor
    Khodaveisi, Javed
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    Saberi, Dariush
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 1300 - 1306
  • [28] Fiber optic localized surface plasmon resonance hydrogen sensor based on gold nanoparticles capped with palladium
    Kim, Hyeong-Min
    Kim, Hyo-Jun
    Yang, Seung-Chul
    Park, Jae-Hyoung
    Lee, Seung-Ki
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2022, 111 : 281 - 288
  • [29] Localized surface plasmon resonance based fiber optic sensor with nanoparticles
    Rani, Mahima
    Sharma, Navneet K.
    Sajal, Vivek
    OPTICS COMMUNICATIONS, 2013, 292 : 92 - 100
  • [30] Effects of surface density and size of gold nanoparticles in a fiber-optic localized surface plasmon resonance sensor and its application to peptide detection
    Lee, Hun
    Kim, Hyun-Jin
    Park, Jae-Hyoung
    Jeong, Dae Hong
    Lee, Seung-Ki
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (08)