A test-based method for estimating the service life of adsorptive portable air cleaners in removing indoor formaldehyde

被引:9
|
作者
Zhu, Xiaoyue [1 ]
Lv, Mengqiang [1 ]
Yang, Xudong [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Formaldehyde; Portable air cleaners; Clean air delivery rate; Service life; Simulation; VOLATILE ORGANIC-COMPOUNDS; ACTIVATED CARBON; PERFORMANCE; RESIDENCES; BUILDINGS; POLLUTION; QUALITY; VOCS;
D O I
10.1016/j.buildenv.2019.03.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Portable air cleaners (PACs) with activated carbon filters are frequently used to remove gaseous contaminants. However, activated carbon has a limited adsorption capacity for small polar molecules, such as formaldehyde. Formaldehyde is a ubiquitous air contaminant with hazardous effects to human health. Thus, characterizing carbon filter performance decay and being able to predict the service life of PACs is of high importance. This study proposes a testing method which enables the continuous measurement of the clean air delivery rate (CADR). Vaporized formaldehyde was injected at a constant rate, i.e. 14 mg/h or 45 mg/h, into an air-tight chamber where the PAC was operating. The CADR was calculated from the steady-state concentration in the chamber according to the mass-balance equation. An adsorptive PAC with a pleated composite filter of activated carbon and high efficiency particulate air (HEPA) was tested until the CADR decreased to ca. 30% of its initial value. The functional relationship between the CADR and the cumulative adsorbed mass (CAM) of formaldehyde was established. Then, formaldehyde emission rates and ventilation rates in real Chinese residences were estimated by literature research. The obtained data were used in simulation to investigate PAC service life under a range of different situations. Test results showed that the CADR tended to decay exponentially with the CAM. According to the simulation, the CADR declined by 90% after a duration of 130-190 h under the most strenuous condition. However, PAC service life could be prolonged to more than 2000 h under realistic usage conditions.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 15 条
  • [11] Development of a new direct test method for estimating cutter life, based on the Sievers' J miniature drill test
    Dahl, Filip
    Grov, Eivind
    Breivik, Torkjell
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2007, 22 (01) : 106 - 116
  • [12] Forecast model for estimating the service life of a diagnosed object based on the Neyman-Pearson method
    Barsukov, Sergey
    Pakhomov, Sergey
    X INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE POLYTRANSPORT SYSTEMS, 2018, 216
  • [13] Estimating Service Life Based on the Sound Insulation Performance of Wood Sound Barriers Using an Accelerated Deterioration Test
    Sueyshi, Shuzo
    Ukyo, Seiichiro
    Morikawa, Takeshi
    Machida, Hatsuo
    Oguro, Syoji
    MOKUZAI GAKKAISHI, 2014, 60 (02): : 107 - 112
  • [14] Prediction of VOC adsorption performance for estimation of service life of activated carbon based filter media for indoor air purification
    Ligotski, Roman
    Sager, Uta
    Schneiderwind, Ute
    Asbach, Christof
    Schmidt, Frank
    BUILDING AND ENVIRONMENT, 2019, 149 : 146 - 156
  • [15] Self-indicating and high-capacity mesoporous aerogel-based biosorbent fabricated from cellulose and chitosan via co-dissolution and regeneration for removing formaldehyde from indoor air
    Liao, Yang
    Pan, Xuejun
    ENVIRONMENTAL SCIENCE-NANO, 2021, 8 (05) : 1283 - 1295