A test-based method for estimating the service life of adsorptive portable air cleaners in removing indoor formaldehyde

被引:9
|
作者
Zhu, Xiaoyue [1 ]
Lv, Mengqiang [1 ]
Yang, Xudong [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Formaldehyde; Portable air cleaners; Clean air delivery rate; Service life; Simulation; VOLATILE ORGANIC-COMPOUNDS; ACTIVATED CARBON; PERFORMANCE; RESIDENCES; BUILDINGS; POLLUTION; QUALITY; VOCS;
D O I
10.1016/j.buildenv.2019.03.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Portable air cleaners (PACs) with activated carbon filters are frequently used to remove gaseous contaminants. However, activated carbon has a limited adsorption capacity for small polar molecules, such as formaldehyde. Formaldehyde is a ubiquitous air contaminant with hazardous effects to human health. Thus, characterizing carbon filter performance decay and being able to predict the service life of PACs is of high importance. This study proposes a testing method which enables the continuous measurement of the clean air delivery rate (CADR). Vaporized formaldehyde was injected at a constant rate, i.e. 14 mg/h or 45 mg/h, into an air-tight chamber where the PAC was operating. The CADR was calculated from the steady-state concentration in the chamber according to the mass-balance equation. An adsorptive PAC with a pleated composite filter of activated carbon and high efficiency particulate air (HEPA) was tested until the CADR decreased to ca. 30% of its initial value. The functional relationship between the CADR and the cumulative adsorbed mass (CAM) of formaldehyde was established. Then, formaldehyde emission rates and ventilation rates in real Chinese residences were estimated by literature research. The obtained data were used in simulation to investigate PAC service life under a range of different situations. Test results showed that the CADR tended to decay exponentially with the CAM. According to the simulation, the CADR declined by 90% after a duration of 130-190 h under the most strenuous condition. However, PAC service life could be prolonged to more than 2000 h under realistic usage conditions.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 15 条
  • [1] Removing indoor particles using portable air cleaners: Implications for residential infection transmission
    Zuraimi, M. S.
    Nilsson, G. J.
    Magee, R. J.
    BUILDING AND ENVIRONMENT, 2011, 46 (12) : 2512 - 2519
  • [2] A New Clean Air Delivery Rate Test Applied to Five Portable Indoor Air Cleaners
    Molgaard, Bjarke
    Koivisto, Antti Joonas
    Hussein, Tareq
    Haemeri, Kaarle
    AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (04) : 409 - 417
  • [3] Estimating formaldehyde concentrations in indoor air in a full-scale test house
    Yoshida, H
    Nanami, N
    Ohono, T
    Inoue, A
    Tamura, A
    Omi, K
    WOOD ADHESIVES 2000, 2001, : 283 - 284
  • [4] Performance test method for portable air cleaners to remove single gaseous chemical substance
    Hasegawa, Asako
    Komine, Hiromi
    Kamata, Motoyasu
    HVAC&R RESEARCH, 2011, 17 (04): : 504 - 512
  • [5] Performance of sorption-based portable air cleaners in formaldehyde removal: Laboratory tests and field verification
    Zhu, Xiaoyue
    Lv, Mengqiang
    Yang, Xudong
    BUILDING AND ENVIRONMENT, 2018, 136 : 177 - 184
  • [6] Diaminopropane-appended activated carbons for the adsorptive removal of gaseous formaldehyde using a portable indoor air purification unit
    Sun, Shaoqing
    Vikrant, Kumar
    Verma, Swati
    Boukhvalov, Danil W.
    Kim, Ki-Hyun
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2024, 653 : 992 - 1005
  • [7] Quantification of Byproduct Formation from Portable Air Cleaners Using a Proposed Standard Test Method
    Link, Michael F.
    Robertson, Rileigh
    Claflin, Megan S.
    Poppendieck, Dustin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (18) : 7916 - 7923
  • [8] A predictive model for the formaldehyde removal performance of sorption-based portable air cleaners with pleated composite filter
    Zhu, Xiaoyue
    Lv, Mengqiang
    Yang, Xudong
    BUILDING AND ENVIRONMENT, 2019, 147 : 517 - 527
  • [9] Energy-efficient operation of portable air cleaners based on real-time prediction of non-uniform concentrations of indoor air pollutants in open offices
    Chen, Difei
    Liu, Mingqi
    Guo, Weichen
    Li, Yiqun
    Xu, Bin
    Ye, Wei
    BUILDING AND ENVIRONMENT, 2024, 256
  • [10] A CFD-based test method for control of indoor environment in air-conditioned rooms
    Li, Kangji
    Su, Hongye
    Chu, Jian
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 6933 - 6937