Nonintrusive Load Monitoring of Variable Speed Drive Cooling Systems

被引:5
|
作者
Lindahl, Peter A. [1 ]
Ali, Muhammad Tauha [2 ]
Armstrong, Peter [2 ]
Aboulian, Andre [3 ]
Donnal, John [4 ]
Norford, Les [5 ]
Leeb, Steven B. [3 ]
机构
[1] Exponent Inc, Natick, MA 01760 USA
[2] Khalifa Univ Sci & Technol, Dept Mech Engn, Abu Dhabi, U Arab Emirates
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] US Naval Acad, Weapons & Syst Engn Dept, Annapolis, MD 21402 USA
[5] MIT, Dept Architecture, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
Cooling; Buildings; Monitoring; Refrigerants; Harmonic analysis; Heating systems; Power system harmonics; Air conditioning; condition monitoring; cooling; HVAC; nonintrusive load monitoring; smart meters; variable speed drives; ENERGY-CONSUMPTION; DISAGGREGATION; MODEL; TEMPERATURE;
D O I
10.1109/ACCESS.2020.3039408
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To improve the energy efficiencies of building cooling systems, manufacturers are increasingly utilizing variable speed drive (VSD) motors in system components, e.g. compressors and condensers. While these technologies can provide significant energy savings, these benefits are only realized if these components operate as intended and under proper control. Undetected faults can foil efficiency gains. As such, it's imperative to monitor cooling system performance to both identify faulty conditions and to properly inform building or multi-building models used for predictive control and energy management. This paper presents nonintrusive load monitoring (NILM) based "mapping" techniques for tracking the performance of a building's central air conditioning from smart electrical meter or energy monitor data. Using a multivariate linear model, a first mapping disaggregates the air conditioner's power draw from that of the total building by exploiting the correlations between the building's line-current harmonics and the power consumption of the air conditioner's VSD motors. A second mapping then estimates the air conditioner's heat rejection performance using as inputs the estimated power draw of the first mapping, the building's zonal temperature, and the outside environmental temperature. The usefulness of these mapping techniques are demonstrated using data collected from a research facility building on the Masdar City Campus of Khalifa University. The mapping techniques combine to provide accurate estimates of the building's air conditioning performance when operating under normal conditions. These estimates could thus be used as feedback in building energy management controllers and can provide a performance baseline for detection of air conditioner underperformance.
引用
收藏
页码:211451 / 211463
页数:13
相关论文
共 50 条
  • [41] Cooling Systems of Large-Capacity Adjustable-Speed Drive Systems
    Verma, Manish
    Phares, Douglas
    Grinbaum, Izhak
    Nanney, James
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) : 148 - 158
  • [42] A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation
    Mayhorn, Ebony
    Butzbaugh, Joshua
    Meier, Alan
    SENSORS, 2023, 23 (19)
  • [43] Sensorless online measurements: application to variable speed drive systems
    Al-Tahir, Ali Abdul Razzaq
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 37 (01) : 29 - 53
  • [44] Nonintrusive Appliance Load Monitoring Based on Integer Programming
    Suzuki, Kosuke
    Inagaki, Shinkichi
    Suzuki, Tatsuya
    Nakamura, Hisahide
    Ito, Koichi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 2626 - +
  • [45] Instrumentation for high performance nonintrusive electrical load monitoring
    Shaw, SR
    Abler, CB
    Lepard, RF
    Luo, D
    Leeb, SB
    Norford, LK
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (03): : 224 - 229
  • [46] CES PRESS DRIVES VARIABLE SPEED PRESS DRIVE SYSTEMS
    BALMES, RJ
    METAL STAMPING, 1971, 5 (02): : 5 - &
  • [47] Nonintrusive Load Monitoring: Making Smart Meters Smarter
    Bedi, DeepRaj
    Sharma, Vineet
    INTELLIGENT COMPUTING TECHNIQUES FOR SMART ENERGY SYSTEMS, 2020, 607 : 789 - 794
  • [48] Nonintrusive appliance load monitoring based on integer programming
    Inagaki, Shinkichi
    Egami, Tsukasa
    Suzuki, Tatsuya
    Nakamura, Hisahide
    Ito, Koichi
    IEEJ Transactions on Power and Energy, 2008, 128 (11) : 1386 - 1392
  • [49] Transformer for Nonintrusive Load Monitoring: Complexity Reduction and Transferability
    Wang, Lingxiao
    Mao, Shiwen
    Nelms, R. Mark
    IEEE INTERNET OF THINGS JOURNAL, 2022, 9 (19) : 18987 - 18997
  • [50] Hidden Markov Models for Nonintrusive Appliance Load Monitoring
    Mueller, Jacob A.
    Sankara, Anusha
    Kimball, Jonathan W.
    McMillin, Bruce
    2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,