Nonintrusive Load Monitoring of Variable Speed Drive Cooling Systems

被引:5
|
作者
Lindahl, Peter A. [1 ]
Ali, Muhammad Tauha [2 ]
Armstrong, Peter [2 ]
Aboulian, Andre [3 ]
Donnal, John [4 ]
Norford, Les [5 ]
Leeb, Steven B. [3 ]
机构
[1] Exponent Inc, Natick, MA 01760 USA
[2] Khalifa Univ Sci & Technol, Dept Mech Engn, Abu Dhabi, U Arab Emirates
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] US Naval Acad, Weapons & Syst Engn Dept, Annapolis, MD 21402 USA
[5] MIT, Dept Architecture, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
Cooling; Buildings; Monitoring; Refrigerants; Harmonic analysis; Heating systems; Power system harmonics; Air conditioning; condition monitoring; cooling; HVAC; nonintrusive load monitoring; smart meters; variable speed drives; ENERGY-CONSUMPTION; DISAGGREGATION; MODEL; TEMPERATURE;
D O I
10.1109/ACCESS.2020.3039408
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To improve the energy efficiencies of building cooling systems, manufacturers are increasingly utilizing variable speed drive (VSD) motors in system components, e.g. compressors and condensers. While these technologies can provide significant energy savings, these benefits are only realized if these components operate as intended and under proper control. Undetected faults can foil efficiency gains. As such, it's imperative to monitor cooling system performance to both identify faulty conditions and to properly inform building or multi-building models used for predictive control and energy management. This paper presents nonintrusive load monitoring (NILM) based "mapping" techniques for tracking the performance of a building's central air conditioning from smart electrical meter or energy monitor data. Using a multivariate linear model, a first mapping disaggregates the air conditioner's power draw from that of the total building by exploiting the correlations between the building's line-current harmonics and the power consumption of the air conditioner's VSD motors. A second mapping then estimates the air conditioner's heat rejection performance using as inputs the estimated power draw of the first mapping, the building's zonal temperature, and the outside environmental temperature. The usefulness of these mapping techniques are demonstrated using data collected from a research facility building on the Masdar City Campus of Khalifa University. The mapping techniques combine to provide accurate estimates of the building's air conditioning performance when operating under normal conditions. These estimates could thus be used as feedback in building energy management controllers and can provide a performance baseline for detection of air conditioner underperformance.
引用
收藏
页码:211451 / 211463
页数:13
相关论文
共 50 条
  • [1] Nonintrusive load monitoring and diagnostics in power systems
    Shaw, Steven R.
    Leeb, Steven B.
    Norford, Leslie K.
    Cox, Robert W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (07) : 1445 - 1454
  • [2] A Novel Search Scheme for Nonintrusive Load Monitoring Systems
    Lai, Yi-Sheng
    Chen, Yung-Chi
    Tsao, Shiao-Li
    Tsai, Tzung-Cheng
    2012 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2012, : 102 - 107
  • [3] Remote Monitoring of Fluid Handling Systems with Variable-Speed Drive
    Ahonen, Tero
    Poyhonen, Santeri
    Ahola, Jero
    Siimesjarvi, Joni
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [4] NONINTRUSIVE APPLIANCE LOAD MONITORING
    HART, GW
    PROCEEDINGS OF THE IEEE, 1992, 80 (12) : 1870 - 1891
  • [5] Water Nonintrusive Load Monitoring
    Schantz, Christopher
    Donnal, John
    Sennett, Brian
    Gillman, Mark
    Muller, Sean
    Leeb, Steven
    IEEE SENSORS JOURNAL, 2015, 15 (04) : 2177 - 2185
  • [6] CHOICE OF VARIABLE SPEED DRIVE SYSTEMS
    MEDERER, R
    POLL, NJ
    ELECTRICAL REVIEW, 1971, 189 (03): : 79 - &
  • [7] Study of incipient bearing damage monitoring in variable-speed drive systems
    Romanenko, Aleksei
    Ahola, Jero
    Muetze, Annette
    Niskanen, Ville
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [8] Nonintrusive appliance load monitoring system
    EPRI Journal, 1990, 15 (06):
  • [9] Energy efficiency of variable speed drive systems
    Rooks, JA
    Wallace, AK
    CONFERENCE RECORD OF THE 2003 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2003, : 160 - 163
  • [10] PROLOG TO NONINTRUSIVE APPLIANCE LOAD MONITORING
    LIKOUREZOS, G
    PROCEEDINGS OF THE IEEE, 1992, 80 (12) : 1869 - 1869