Effectiveness of additional X-ray protection devices in reducing scattered radiation in radial intervention: the ESPRESSO randomised trial

被引:7
|
作者
Anadol, Remzi
Brandt, Moritz
Merz, Nico
Knorr, Maike
Ahoopai, Majid
Geyer, Martin
Krompiec, Damian
Wenzel, Phillip
Munzel, Thomas
Gori, Tommaso
机构
[1] Univ Med Mainz, Kardiol 1, Zentrum Kardiol, Mainz, Germany
[2] DZHK Standort Rhein Main, Mainz, Germany
关键词
clinical research; clinical trials; drug-eluting stent; radial; radiation protection; PERCUTANEOUS CORONARY INTERVENTIONS; BRAIN-TUMORS; EXPOSURE; OPERATOR; CATHETERIZATION; CARDIOLOGISTS; ANGIOGRAMS; ACCESS; STAFF; RISK;
D O I
10.4244/EIJ-D-19-00945
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We aimed to examine the impact of three different radiation protection devices in a real-world setting of radial artery catheterisation. Methods and results: In an all-comer randomised trial, consecutive coronary radial diagnostic and intervention procedures were assigned in a 1:1:1 ratio to shield-only protection (shield group), shield and overlapping 0.5 mm Pb panel curtain (shield+curtain group) or shield, curtain and additional 75x40 cm, 0.5 mm Pb drape placed across the waist of the patient (shield+curtain+drape group). A total of 614 radial procedures were randomised (n=193 shield, n=220 shield+curtain, n=201 shield+curtain+drape). There were no differences among the groups in patient or procedural characteristics. The primary endpoint (relative exposure ratio between the operators' exposure in mu Sv and the patient's exposure, dose area product in cGy.cm(2)) was significantly lower in the shield+curtain+drape group for both the first operator (20% reduction vs shield, 16% vs shield+curtain, p=0.025) and the assistant (39% reduction vs shield, 25% vs shield+curtain, p=0.009). Conclusions: The use of an additional drape reduced the radiation exposure of both the first operator and the second operator during routine radial procedures; a shield-attached curtain alone was only partially effective.
引用
收藏
页码:663 / +
页数:13
相关论文
共 12 条
  • [1] Effectiveness of additional X-ray protection devices in reducing Scattered radiation in radial interventions: protocol of the ESPRESSO randomised trial
    Anadol, Remzi
    Brandt, Moritz
    Merz, Nico
    Knorr, Maike
    Ahoopai, Majid
    Geyer, Martin
    Krompiec, Damian
    Wenzel, Phillip
    Muenzel, Thomas
    Gori, Tommaso
    BMJ OPEN, 2019, 9 (07):
  • [2] Effectiveness of a Real-Time X-ray Dosimetry Monitor in Reducing Radiation Exposure in Coronary Procedures: The ESPRESSO-Raysafe Randomized Trial
    Olschewski, Maximilian
    Ullrich, Helen
    Brandt, Moritz
    Steven, Sebastian
    Ahoopai, Majid
    Blessing, Recha
    Petrescu, Aniela
    Wenzel, Philip
    Munzel, Thomas
    Gori, Tommaso
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (22)
  • [3] Matching Primary and Scattered X-Ray Spectra for Use in Calculating the Diagnostic Radiation Index of Protection
    Pasciak, A.
    Jones, A.
    Wagner, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 147 - 148
  • [4] Reduced operator radiation exposure during transradial coronary angiography using additional x-ray protection measures
    Minden, H-H.
    Brilla, K.
    Herbstleb, J.
    Koenig-Gorsleben, M.
    Schau, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1037 - 1037
  • [5] Effectiveness of peer educators on the uptake of mobile X-ray tuberculosis screening at homeless hostels: a cluster randomised controlled trial
    Aldridge, Robert W.
    Hayward, Andrew C.
    Hemming, Sara
    Possas, Lucia
    Ferenando, Gloria
    Garber, Elizabeth
    Lipman, Marc
    McHugh, Timothy D.
    Story, Alistair
    BMJ OPEN, 2015, 5 (09):
  • [6] Reducing Pediatric Intraoral Radiography Radiation Dose Using Reduced-Power Dental X-Ray Units: A Randomized Trial
    Cully, Jennifer L.
    Somasundaram, Elanchezhian
    Campbell, Richard
    Brady, Samuel L.
    Gosnell, Elizabeth S.
    Specht, Sarah
    Candon, Lisa Atlas
    Strauss, Keith J.
    JOURNAL OF DENTISTRY FOR CHILDREN, 2022, 89 (02) : 95 - 103
  • [7] Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory A Randomized Controlled Trial
    McCutcheon, Keir
    Vanhaverbeke, Maarten
    Pauwels, Ruben
    Dabin, Jeremie
    Schoonjans, Werner
    Bennett, Johan
    Adriaenssens, Tom
    Dubois, Christophe
    Sinnaeve, Peter
    Desmet, Walter
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (11) : E009627
  • [8] DETERMINATION OF CALIBRATION X-RAY BEAM QUALITIES AND ESTABLISH A SET OF CONVERSION COEFFICIENTS FOR CALIBRATION OF RADIATION PROTECTION DEVICES USED IN DIAGNOSTIC RADIOLOGY
    Siddiqua, Tanjim
    Rahman, Md Shakilur
    Sanaullah, Md
    Mitu, Zohora Akter
    Hossain, Imran
    Rubai, Sadeka Sultana
    EAST EUROPEAN JOURNAL OF PHYSICS, 2021, (03): : 55 - 61
  • [9] Radiation dose esclation with contact X-ray brachytherapy (Papillon) and quality of life in patients with rectal cancer: Results from the phase 3 randomised trial OPERA
    Myint, Arthur Sun
    Than, Nguwah
    Pace-Loscos, Tanguy
    Schiappa, Renaud
    Ai-Haq, Muneeb
    Sripadam, Rajaram
    Rao, Christopher
    Stead, Sarah
    Pritchard, D. Mark
    Gerard, Jean Pierre
    JOURNAL OF CLINICAL ONCOLOGY, 2024, 42 (16)
  • [10] Computer-aided X-ray screening for tuberculosis and HIV testing among adults with cough in Malawi (the PROSPECT study): A randomised trial and cost-effectiveness analysis
    MacPherson, Peter G.
    Webb, Emily H.
    Kamchedzera, Wala T.
    Joekes, Elizabeth M.
    Mjoli, Gugu
    Lalloo, David
    Divala, Titus
    Choko, Augustine
    Burke, Rachael L.
    Maheswaran, Hendramoorthy
    Pai, Madhukar
    Squire, S. Bertel
    Nliwasa, Marriott
    Corbett, Elizabeth
    PLOS MEDICINE, 2021, 18 (09)