Reducing Pediatric Intraoral Radiography Radiation Dose Using Reduced-Power Dental X-Ray Units: A Randomized Trial

被引:0
|
作者
Cully, Jennifer L. [1 ]
Somasundaram, Elanchezhian [2 ]
Campbell, Richard [1 ]
Brady, Samuel L. [2 ]
Gosnell, Elizabeth S. [1 ]
Specht, Sarah
Candon, Lisa Atlas
Strauss, Keith J. [3 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Div Pediat Dent & Orthodont, Orthodont, Cincinnati, OH 45229 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Div Clin Med Phys & Radiol, Cincinnati, OH 45229 USA
[3] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Sch Med, Cincinnati, OH 45221 USA
关键词
PEDIATRIC DENTISTRY; DENTAL RADIOGRAPHY; PATIENT SAFETY; ORAL RADIOLOGY; FILTERS; REDUCTION; IMAGE; PROTECTION; QUALITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To assess the diagnostic confidence of intraoral radiographic image quality while reducing the pediatric patient's radiation exposure using a longer position indicating device (PID), additional X-ray beam filtration and rectangular collimation while using modern, lower-power intraoral dental X-ray units. Methods: A randomized prospective study scored bitewing intraoral dental images based on relevant clinical features. Observer studies with pediatric dentists and dental residents were conducted to verify whether diagnostic confidence remained unchanged after dose reduction modifications. The study involved a two-phase investigation to determine: (1) the best thickness of aluminum (Al) 2024-T3 alloy filter and (2) required increased exposure time to maintain intraoral radiographic image quality. A 30 cm PID with a rectangular collimator was used to further manage patient dose. For each phase, images from 125 patients were collected from February 2017 to September 2018 and analyzed. Results: The results from the observer study using a 30 cm PID, 1.02 mm thick Al alloy filter, and a rectangular collimator resulted in a patient dose reduction between 64 percent (exposure time of 400 msec) to 77 percent (250 msec), without any statis-tically significant effect to the diagnostic confidence of the observers in evaluating the reduced radiation images. Conclusion: Long recognized dose reduction methods, when implemented on a modern, low-power intraoral dental X-ray unit, do not impact confidence in bite -wing diagnostic images, but substantially reduce patient dose and should be adopted to increase patient safety, especially for children.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [1] DENTAL PANORAMIC RADIOGRAPHY WITH INTRAORAL X-RAY TUBES
    KEUR, JJ
    MACDONALD, R
    AUSTRALIAN DENTAL JOURNAL, 1986, 31 (01) : 40 - 43
  • [2] DENTAL STAFF DOSES WITH HANDHELD DENTAL INTRAORAL X-RAY UNITS
    Gray, Joel E.
    Bailey, Edgar D.
    Ludlow, John B.
    HEALTH PHYSICS, 2012, 102 (02): : 137 - 142
  • [3] THE INTEGRAL DOSE IN PANORAMIC INTRAORAL X-RAY TUBE RADIOGRAPHY
    HAYAMI, A
    FUJISHITA, M
    SUMIDA, A
    KANKE, M
    FUJIKI, T
    UEMURA, S
    FUCHIHATA, H
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (01): : 98 - 102
  • [4] An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography
    Kim, Hyun Jin
    Kim, Hyun Nam
    Raza, Hamid Saeed
    Park, Han Beom
    Cho, Sung Oh
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (03) : 799 - 804
  • [5] Bismuth Pelvic X-Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
    Wang, Bow
    Ting, Chien-Yi
    Lai, Cheng-Shih
    Tsai, Yi-Shan
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [6] RADIATION HAZARDS FROM THE USE OF DENTAL X-RAY UNITS
    NOLAN, WE
    PATTERSON, HW
    JOURNAL OF DENTAL RESEARCH, 1953, 32 (05) : 673 - 673
  • [7] RADIATION HAZARDS FROM THE USE OF DENTAL X-RAY UNITS
    NOLAN, WE
    PATTERSON, HW
    RADIOLOGY, 1953, 61 (04) : 625 - 629
  • [8] Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory A Randomized Controlled Trial
    McCutcheon, Keir
    Vanhaverbeke, Maarten
    Pauwels, Ruben
    Dabin, Jeremie
    Schoonjans, Werner
    Bennett, Johan
    Adriaenssens, Tom
    Dubois, Christophe
    Sinnaeve, Peter
    Desmet, Walter
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (11) : E009627
  • [9] A LIMITED SURVEY OF RADIATION EXPOSURE FROM DENTAL X-RAY UNITS
    GORSON, RO
    HALVORSEN, RM
    LIEBERMAN, J
    AITKEN, EV
    RADIOLOGY, 1959, 72 (01) : 1 - 13
  • [10] INTRAORAL DENTAL X-RAY RADIOGRAPHY IN BOSNIA AND HERZEGOVINA: STUDY FOR REVISING DIAGNOSTIC REFERENCE LEVEL VALUE
    Praskalo, Jovica
    Beganovic, Adnan
    Milanovic, Jovana
    Stankovic, Koviljka
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (01) : 90 - 99