Reducing Pediatric Intraoral Radiography Radiation Dose Using Reduced-Power Dental X-Ray Units: A Randomized Trial

被引:0
|
作者
Cully, Jennifer L. [1 ]
Somasundaram, Elanchezhian [2 ]
Campbell, Richard [1 ]
Brady, Samuel L. [2 ]
Gosnell, Elizabeth S. [1 ]
Specht, Sarah
Candon, Lisa Atlas
Strauss, Keith J. [3 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Div Pediat Dent & Orthodont, Orthodont, Cincinnati, OH 45229 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Div Clin Med Phys & Radiol, Cincinnati, OH 45229 USA
[3] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Sch Med, Cincinnati, OH 45221 USA
关键词
PEDIATRIC DENTISTRY; DENTAL RADIOGRAPHY; PATIENT SAFETY; ORAL RADIOLOGY; FILTERS; REDUCTION; IMAGE; PROTECTION; QUALITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To assess the diagnostic confidence of intraoral radiographic image quality while reducing the pediatric patient's radiation exposure using a longer position indicating device (PID), additional X-ray beam filtration and rectangular collimation while using modern, lower-power intraoral dental X-ray units. Methods: A randomized prospective study scored bitewing intraoral dental images based on relevant clinical features. Observer studies with pediatric dentists and dental residents were conducted to verify whether diagnostic confidence remained unchanged after dose reduction modifications. The study involved a two-phase investigation to determine: (1) the best thickness of aluminum (Al) 2024-T3 alloy filter and (2) required increased exposure time to maintain intraoral radiographic image quality. A 30 cm PID with a rectangular collimator was used to further manage patient dose. For each phase, images from 125 patients were collected from February 2017 to September 2018 and analyzed. Results: The results from the observer study using a 30 cm PID, 1.02 mm thick Al alloy filter, and a rectangular collimator resulted in a patient dose reduction between 64 percent (exposure time of 400 msec) to 77 percent (250 msec), without any statis-tically significant effect to the diagnostic confidence of the observers in evaluating the reduced radiation images. Conclusion: Long recognized dose reduction methods, when implemented on a modern, low-power intraoral dental X-ray unit, do not impact confidence in bite -wing diagnostic images, but substantially reduce patient dose and should be adopted to increase patient safety, especially for children.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [21] A new phantom for remote monitoring of dose and image quality in dental X-ray units
    Goodenough, DJ
    Levy, JR
    Wormuth, JR
    RADIOLOGY, 1997, 205 : 1404 - 1404
  • [22] Point-projection x-ray radiography using an X pinch as the radiation source
    Shelkovenko, TA
    Sinars, DB
    Pikuz, SA
    Chandler, KM
    Hammer, DA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 667 - 670
  • [23] Phase-contrast x-ray radiography using X pinch radiation.
    Pikuz, SA
    Shelkovenko, TA
    Sinars, DB
    Chandler, KM
    Hammer, DA
    APPLICATIONS OF X RAYS GENERATED FROM LASERS AND OTHER BRIGHT SOURCES II, 2001, 4504 : 234 - 239
  • [24] Comparison of the Operator and Surrounding Dose When Using Portable Intraoral X-ray Devices
    Abdinian, Mehrdad
    Aminian, Maedeh
    Keymasi, Forouzan
    Soltani, Parisa
    Cernera, Mariangela
    Armogida, Niccolo Giuseppe
    Spagnuolo, Gianrico
    APPLIED SCIENCES-BASEL, 2024, 14 (08):
  • [25] Intraoral Radiology in General Dental Practices - A Comparison of Digital and Film-Based X-Ray Systems with Regard to Radiation Protection and Dose Reduction
    Anissi, H. D.
    Geibel, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (08): : 762 - 767
  • [26] RADIATION DOSE MEASUREMENTS FOR OPTIMISATION OF CHEST X-RAY EXAMINATIONS OF CHILDREN IN GENERAL RADIOGRAPHY HOSPITALS
    Suliman, Ibrahim I.
    Elawed, Sahar O.
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 310 - 314
  • [27] Imaging of scattered radiation sources in X-ray radiography using a semiconductor radiation visualization camera
    Sakai, Mayu
    Fujibuchi, Toshioh
    Lee, Hyojin
    Han, Donghee
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 308 - 315
  • [28] Reduction in Radiation Dose in a Pediatric Cardiac Catheterization Lab Using the Philips AlluraClarity X-ray System
    Patrick M. Sullivan
    David Harrison
    Sarah Badran
    Cheryl M. Takao
    Frank F. Ing
    Pediatric Cardiology, 2017, 38 : 1583 - 1591
  • [29] Reduction in Radiation Dose in a Pediatric Cardiac Catheterization Lab Using the Philips AlluraClarity X-ray System
    Sullivan, Patrick M.
    Harrison, David
    Badran, Sarah
    Takao, Cheryl M.
    Ing, Frank F.
    PEDIATRIC CARDIOLOGY, 2017, 38 (08) : 1583 - 1591
  • [30] THYROID RADIATION-DOSE DURING PANORAMIC AND CEPHALOMETRIC DENTAL X-RAY EXAMINATIONS
    BLOCK, AJ
    GOEPP, RA
    MASON, EW
    ANGLE ORTHODONTIST, 1977, 47 (01) : 17 - 24