Shear Strength of Reinforced Concrete Columns Retrofitted by Glass Fiber Reinforced Polyurea

被引:12
|
作者
Song, Jun-Hyeok [1 ]
Lee, Eun-Taik [2 ]
Eun, Hee-Chang [1 ]
机构
[1] Kangwon Natl Univ, Dept Architectural Engn, Chunchon, South Korea
[2] Chung Ang Univ, Dept Architectural Engn, Seoul, South Korea
来源
CIVIL ENGINEERING JOURNAL-TEHRAN | 2020年 / 6卷 / 10期
关键词
Retrofit; Coating; Polyurea; Strengthening; Reinforced Concrete Column; Shear Crack; RC COLUMNS; SEISMIC RETROFIT; COMPOSITES; BEHAVIOR; FRP;
D O I
10.28991/cej-2020-03091587
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aged structures and structures constructed based on outdated non-seismic design codes should be retrofitted to enhance their strength, ductility, and durability. This study evaluates the structural performance of Reinforced Concrete (RC) columns enhanced via polyurea or Glass Fiber Reinforced Polyurea (GFRPU) strengthening. Four RC column specimens, including a reference specimen (an unstrengthened column), were tested to evaluate the parameters of the strengthening materials and the strengthened area. The tests were carried out under a combined constant axial compressive load and quasi-static cyclic loading. The experimental results show that the composite strengthening provides lateral confinement to the columns and leads to enhanced ductility, shear-resistance capacity, and dissipated energy. The shear strength provided by the composites depends on the degree of lateral confinement achieved by the composite coating. The specimens finally failed through the development of diagonal tension cracks within the potential plastic hinge regions. The specimen treated with GFRPU strengthening showed greater strength and dissipated more energy than the specimen treated with polyurea strengthening. Furthermore, by modifying ATC-40, this study proposed an equation to estimate the shear capacity provided by the composites.
引用
收藏
页码:1852 / 1863
页数:12
相关论文
共 50 条
  • [21] Punching shear strength of reinforced concrete slabs strengthened with glass fiber-reinforced, polymer laminates
    Chen, CC
    Li, CY
    ACI STRUCTURAL JOURNAL, 2005, 102 (04) : 535 - 542
  • [22] Shear strength of glass fiber reinforced polymer - reinforced concrete continuous beams without transverse reinforcement
    Mahmoud, Karam
    El-Salakawy, Ehab
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2015, 42 (12) : 1073 - 1082
  • [23] Shear Strength of Circular Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer Bars and Spirals
    Ali, Ahmed H.
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2017, 114 (01) : 39 - 49
  • [24] Bending and punching shear strength of fiber-reinforced glass concrete slabs
    Mu, B
    Meyer, C
    ACI MATERIALS JOURNAL, 2003, 100 (02) : 127 - 132
  • [25] Strengthening of rectangular reinforced concrete columns using fiber glass reinforced polymers
    Elzanaty, A. H.
    Allam, H. M.
    Fawzi, A.
    CONCRETE SOLUTIONS, 2012, : 607 - 614
  • [26] Confinement of reinforced concrete columns with glass fiber reinforced cementitious matrix jackets
    Faleschini, Flora
    Zanini, Mariano Angelo
    Hofer, Lorenzo
    Toska, Klajdi
    De Domenico, Dario
    Pellegrino, Carlo
    ENGINEERING STRUCTURES, 2020, 218
  • [27] Shear strength and behavior of steel fiber reinforced concrete columns under seismic loading
    Lee, Hyun-Ho
    ENGINEERING STRUCTURES, 2007, 29 (07) : 1253 - 1262
  • [28] Experimental study of shear behavior of high strength steel fiber reinforced concrete columns
    Perceka, Wisena
    Liao, Wen-Cheng
    ENGINEERING STRUCTURES, 2021, 240
  • [29] Experimental study on reinforced concrete columns wrapped with glass fiber reinforced polymers
    Sun, Jing
    Hui, Jun-Min
    Tang, Yong-Sheng
    2003, Science Press (35):
  • [30] Shear strength model of shear-critical reinforced concrete columns
    Yu B.
    Wu R.
    Chen B.
    Tao B.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2018, 37 (08): : 180 - 189