Normalized glandular dose (DgN) coefficients from experimental mammographic x-ray spectra

被引:5
|
作者
Santos, Josilene C. [1 ]
Tomal, Alessandra [2 ]
de Barros, Nestor [3 ]
Costa, Paulo R. [1 ]
机构
[1] Univ Sao Paulo, Inst Fis, BR-05508090 Sao Paulo, SP, Brazil
[2] IFGW UNICAMP, Inst Fis Gleb Wataghin, BR-13083859 Campinas, SP, Brazil
[3] Univ Sao Paulo, Fac Med, BR-05403900 Sao Paulo, SP, Brazil
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 10期
基金
巴西圣保罗研究基金会;
关键词
mammography; normalized glandular dose coefficients; x-ray spectrometry; dosimetry; MONTE-CARLO; BREAST DOSIMETRY;
D O I
10.1088/1361-6560/ab171a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mean glandular dose is the quantity used for dosimetry in mammography and depends on breast-related characteristics, such as thickness and density, and on the x-ray spectrum used for breast imaging. This work aims to present an experimentally-based method to derive polyenergetic normalized glandular dose coefficients (DgN(p)) from the spectral difference between x-ray spectra incident and transmitted through breast phantoms with glandular/adipose proportions of 30/70 and 50/50 and thicknesses up to 4.5 cm. The spectra were produced by a Mammomat 3000 Nova system using radiographic techniques commonly applied for imaging compressed breast thickness lower than 6 cm (Mo/Mo, Mo/Rh and W/Rh spectra at 26 and 28 kVp). DgN(p) coefficients were compared with values estimated using Boones' method and data from breast images (DICOM Organ Dose and VolparaDose calculations). The DgN(p) were also evaluated in layers into the phantoms (depth-DgN(p)) using both x-ray spectra and thermoluminescent dosimeters (TLD-100). Maximum differences between DgN(p) from the method presented in this study and results using Boone's method was 11%, with larger differences for Mo/Rh spectra in relation to the Mo/Mo. The DgN(p) maximum differences to the coefficients obtained using patient images were 8.0%, for the DgN calculated using Volpara and 6.4% for the DgN from DICOM Organ Dose, for a 4.5 cm breast phantom with 30% glandularity. The DgN(p) estimated from the depth-DgN(p) distributions differ up to 5.2% to the coefficients obtained using the pair incident-transmitted spectra to calculate the DgN(p) directly in the whole phantom. The depth-DgN(p) distributions estimated with TLDs were consistent with the results observed using the experimental spectra, with maximum difference of 3.9%. In conclusion, polyenergetic x-ray spectrometry proved to be an applicable tool for research in dosimetry in mammography allowing spectral characterization. This approach can also be useful for investigation of the influence of x-ray spectra on glandular dose.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Comparison of x-ray spectra and mean glandular dose estimations in computed radiography systems for mammography: Simulations versus measurements
    Gatto, Leandro Barbosa da Silveira
    Braz, Delson
    Pacifico, Leonardo
    Travassos, Paulo
    Magalhaes, Luis Alexandre Goncalves
    RADIATION PHYSICS AND CHEMISTRY, 2024, 216
  • [22] RBE for mammographic X-ray energies
    Law, J.
    Faulkner, K.
    Young, K. C.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (946): : 851 - 852
  • [23] Mammographic x-ray and MR correspondence
    Martí, R
    Rubin, CME
    Denton, E
    Zwiggelaar, R
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 527 - 529
  • [24] Effect of automatic kV selection on dose and contrast for a mammographic X-ray system
    Young, KC
    Ramsdale, ML
    Rust, A
    Cooke, J
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (838): : 1036 - 1042
  • [25] X-RAY LINEAR ATTENUATION COEFFICIENTS IN THE MAMMOGRAPHIC RANGE FOR ULTRASONIC BREAST PHANTOM MATERIALS
    BURKE, TM
    MADSEN, EL
    ZAGZEBSKI, JA
    RADIOLOGY, 1982, 142 (03) : 755 - 757
  • [26] Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling
    Arectout, A.
    Zidouh, I
    Sadeq, Y.
    Azougagh, M.
    Maroufi, B.
    Chakir, E.
    Boukhal, H.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (01) : 301 - 309
  • [27] Towards an experimental benchmark for aluminum X-ray spectra
    Aschke, L.
    Depierreux, S.
    Estabrook, K.G.
    Fournier, K.B.
    Fuchs, J.
    Glenzer, S.
    Lee, R.W.
    Rozmus, W.
    Thoe, R.S.
    Young, P.E.
    Journal of Quantitative Spectroscopy and Radiative Transfer, 2000, 65 (1-3) : 23 - 30
  • [28] Towards an experimental benchmark for aluminum X-ray spectra
    Aschke, L
    Depierreux, S
    Estabrook, KG
    Fournier, KB
    Fuchs, J
    Glenzer, S
    Lee, RW
    Rozmus, W
    Thoe, RS
    Young, PE
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2000, 65 (1-3): : 23 - 30
  • [29] Experimental and theoretical K x-ray spectra of manganese
    Jonnard, P.
    Giorgi, G.
    Bonnelle, C.
    Physical Review A - Atomic, Molecular, and Optical Physics, 2002, 65 (3 A): : 1 - 032507
  • [30] Normalized glandular dose coefficients in mammography, digital breast tomosynthesis and dedicated breast CT
    Sarno, A.
    Mettivier, G.
    Di Lillo, F.
    Tucciariello, R. M.
    Bliznakova, K.
    Russo, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 55 : 142 - 148