The Human Comfort Level in an Energy-Saving Simulation Model of Office Building

被引:1
|
作者
Dzelzitis, Egils [1 ]
Sidenko, Sandra [1 ]
机构
[1] Riga Tech Univ, Fac Civil Engn, Inst Heat Gas & Water Technol, Riga, Latvia
关键词
HEAT-TRANSFER COEFFICIENTS; ELECTRICITY NETWORK; GAS SYSTEM; TEMPERATURE;
D O I
10.1051/e3sconf/202017206009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Currently high attention is drawn to the studies of the influence of pulsating flow to the heat transfer. Such unsteady flows can be created artificially or may appear during the operation of the thermal energy equipment. The purpose of this work is to perform numerical studies of the pulsating fluid flow effect supplied to a panel heating radiator on its heat output; and to determine the effect of pulsations of heat output on a human comfort level as well. Numerical modeling was prepared with CAD/CFD/HVAC complex of SolidWorks/FlowSimulation software. Where the complete system of Navier-Stokes equations and the energy equation were solved using the k-e turbulence model in a non-stationary formulation of the problem. Results of the numerical calculations showed that the periodic pulsating flow of the fluid in the heating radiator during operation, in comparison with the stationary mode, leads to increasing and decreasing in the thermal power of the radiator. But at the same time, with an average estimate, the thermal power with pulsations of the fluid's flow increases for about 10-15% comparing with a stationary mode. Model of the office room in the considered operating mode is not comfortable; this conclusion is based on such criteria as operating temperature, PMV, PPD, identified in the numerical calculations process.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Computer Simulation and Energy-Saving Analysis of a Composite Steel Residential Building
    Peng, XiaoTong
    Lin, Chen
    JOURNAL OF COMPUTERS, 2012, 7 (03) : 798 - 803
  • [32] Influence of Spanish Energy-Saving Standard on Thermal Comfort and Energy Efficiency Owing to the War in Ukraine: Case Study of an Office Building in a Dry Mediterranean Climate
    Perez-Carraminana, Carlos
    Sabatell-Canales, Samuel
    Gonzalez-Aviles, Angel Benigno
    Galiano-Garrigos, Antonio
    BUILDINGS, 2023, 13 (08)
  • [33] An energy-saving method of office building facilities considering Person's location in the floor
    Kaneko, Yosuke
    Kitagami, Shinji
    Matsushita, Masahito
    Shiozuki, Tetsuo
    Koizumi, Hisao
    IEEJ Transactions on Electronics, Information and Systems, 2015, 135 (10): : 1210 - 1221
  • [34] Research on energy-saving power system of office building lighting based on Internet of Things
    Zheng, Yangping
    Qu, Jia
    Yu, Hongtao
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (02): : 52 - 57
  • [35] Experimental Evaluation and Energy Consumption Simulation of Different Energy-Saving Strategies for Building Envelope
    Tang J.-S.
    Leu L.-J.
    Leu, Liang-Jenq, 2018, Chinese Institute of Civil and Hydraulic Engineering (30): : 93 - 105
  • [36] Circuit categorization approach of office building energy consumption based on data features for energy-saving diagnosis
    Liu, Kuixing
    Wang, Xin
    Xue, Lixin
    ENERGY AND BUILDINGS, 2024, 323
  • [37] ENERGY-SAVING AND THERMAL COMFORT FOR HABITATIONS IN A TROPICAL CLIMATE
    JANNOT, Y
    DJIAKO, T
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (03): : 166 - 173
  • [38] Lighting Energy-saving Optimization Model and Simulation of Living Space
    Li, Peng
    Xiao, Hui
    Kang, Qi
    Yan, Yong
    WMSCI 2010: 14TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL I, 2010, : 302 - 307
  • [39] Probe into the Problem of Water-Saving and Energy-Saving in Building
    Yang, Jie
    Tang, Zhonghua
    Song, Yu
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3275 - 3278
  • [40] Analysis on Potential Energy-saving by Ventilation Management in Existent Office Building in Northwest Sichuan PR
    Li, Xianbi
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 512 - 515