The Josephson arbitrary waveform synthesizer can be used as a precision voltage source for both ac and dc signals. Recent improvements in circuit designs have resulted in output voltages greater than 100 mV so that we can investigate ac metrology measurements in the frequency range from 1 kHz to 50 kHz. In this paper we present experimental measurements of several significant error sources that must be considered in order to create an intrinsic ac voltage standard at these frequencies. These results and the corresponding theoretical analysis allow us to move toward creating a practical ac Josephson voltage standard.
引用
收藏
页码:430 / 431
页数:2
相关论文
共 50 条
  • [1] AC Josephson voltage standard error measurements and analysis
    Burroughs, CJ
    Benz, SP
    Dresselhaus, PD
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 542 - 544
  • [2] Uncertainty analysis for ac-dc difference measurements with the AC Josephson voltage standard
    Underwood, Jason M.
    [J]. METROLOGIA, 2019, 56 (01)
  • [3] Experimental Determination of the Voltage Lead Error in an AC Josephson Voltage Standard
    Filipski, Piotr S.
    Boecker, Michael
    Benz, Samuel P.
    Burroughs, Charles J., Jr.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2387 - 2392
  • [4] An AC Josephson voltage standard for AC-DC transfer-standard measurements
    Benz, Samuel P.
    Burroughs, Charles J., Jr.
    Dresselhaus, Paul D.
    Bergren, Norman F.
    Lipe, Thomas E.
    Kinard, J. R.
    Tang, Yi-hua
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 239 - 243
  • [5] Precision measurements of AC Josephson voltage standard operating margins
    Burroughs, CJ
    Benz, SP
    Dresselhaus, PD
    Chong, Y
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) : 624 - 627
  • [6] AC-DC transfer standard measurements and generalized compensation with the AC Josephson voltage standard
    Kieler, Oliver F. O.
    Landim, Regis Pinheiro
    Benz, Samuel P.
    Dresselhaus, Paul D.
    Burroughs, Charles J., Jr.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (04) : 791 - 796
  • [7] Systematic error analysis of stepwise approximated ac waveforms generated by a Programmable Josephson Voltage Standard
    Burroughs, C. J.
    Rufenacht, A.
    Benz, S. P.
    Dresselhaus, P. D.
    [J]. 2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 72 - 73
  • [8] Systematic-error signals in the AC Josephson voltage standard: Measurement and reduction
    Landim, Regis Pinheiro
    Benz, Samuel P.
    Dresselhaus, Paul D.
    Burroughs, Charles J., Jr.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (06) : 1215 - 1220
  • [9] Zero-Compensation Method and Reduced Inductive Voltage Error for the AC Josephson Voltage Standard
    Zhou, Kunli
    Qu, Jifeng
    Benz, Samuel P.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (05)
  • [10] INVERSE AC JOSEPHSON EFFECT VOLTAGE STANDARD
    LEVINSEN, MT
    CHIAO, RY
    FELDMAN, MJ
    TUCKER, BA
    [J]. APPLIED PHYSICS LETTERS, 1977, 31 (11) : 776 - 778