Uncertainty analysis for ac-dc difference measurements with the AC Josephson voltage standard

被引:23
|
作者
Underwood, Jason M. [1 ]
机构
[1] NIST, 100 Bur Dr,MS 8172, Gaithersburg, MD 20899 USA
关键词
quantum voltage standards; uncertainty analysis; Josephson junction arrays; transmission line analysis; ac voltage metrology; ERROR; CALIBRATIONS;
D O I
10.1088/1681-7575/aaf5e5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A detailed analysis of the uncertainties obtained in ac-dc difference measurements with an AC Josephson voltage standard (ACJVS) is presented. For audio frequencies and for voltages less than 200 mV, ac-dc transfers with the ACJVS may reduce the combined uncertainty by factors of 2-10, compared with conventional methods based on thermal converters. Type A uncertainties are predominantly limited by the thermal transfer standard (TTS), or the digital voltmeter used to acquire the output voltage from the TTS. In agreement with earlier work, the transmission line is the primary contributor to Type B errors for frequencies above 10kHz. A Monte Carlo sensitivity analysis is used to demonstrate how the uncertainties of transmission line impedance and on-chip inductance impact the accuracy of the rms amplitude conveyed to the TTS.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] An AC Josephson voltage standard for AC-DC transfer-standard measurements
    Benz, Samuel P.
    Burroughs, Charles J., Jr.
    Dresselhaus, Paul D.
    Bergren, Norman F.
    Lipe, Thomas E.
    Kinard, J. R.
    Tang, Yi-hua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 239 - 243
  • [2] AC-DC transfer standard measurements and generalized compensation with the AC Josephson voltage standard
    Kieler, Oliver F. O.
    Landim, Regis Pinheiro
    Benz, Samuel P.
    Dresselhaus, Paul D.
    Burroughs, Charles J., Jr.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (04) : 791 - 796
  • [3] SYSTEM FOR PRECISION AC-DC DIFFERENCE MEASUREMENTS BASED ON A PROGRAMMABLE JOSEPHSON VOLTAGE STANDARD
    Budovsky, I.
    Georgakopoulos, D.
    Hagen, T.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 50 - 51
  • [4] Extending voltage range to 10 V rms in AC-DC difference measurements with AC programmable Josephson voltage standard
    Amagai, Yasutaka
    Maruyama, Michitaka
    Yamamori, Hirotake
    Shimazaki, Takeshi
    Okawa, Kenjiro
    Fujiki, Hiroyuki
    Kaneko, Nobu-Hisa
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (06)
  • [5] Precision AC-DC Difference Measurement System Based on a Programmable Josephson Voltage Standard
    Budovsky, Ilya
    Georgakopoulos, Dimitrios
    Hagen, Thomas
    Sasaki, Hitoshi
    Yamamori, Hirotake
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2439 - 2444
  • [6] AC-DC DIFFERENCE MEASUREMENTS RELATIVE TO JOSEPHSON GENERATED VOLTAGES
    Palafox, L.
    Behr, R.
    Funck, T.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 91 - 92
  • [7] AC-DC Difference of a Thermal Transfer Standard Measured with a Pulse-Driven Josephson Voltage Standard
    Granger, G.
    Flowers-Jacobs, N. E.
    Rufenacht, A.
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [8] ac Josephson voltage standard error measurements and analysis
    Burroughs, CJ
    Benz, SP
    Dresselhaus, PD
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 430 - 431
  • [9] AC Josephson voltage standard error measurements and analysis
    Burroughs, CJ
    Benz, SP
    Dresselhaus, PD
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 542 - 544
  • [10] AC-DC Calibrations With a Pulse-driven AC Josephson Voltage Standard Operated in a Small Cryostat
    van den Brom, Helko E.
    Kieler, Oliver F. O.
    Bauer, Stephan
    Houtzager, Ernest
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,