Developing a New Neutron and Reactivity Monitoring System for Paks NPP

被引:0
|
作者
Kiss, Sandor [1 ]
Lipcsei, Sandor [1 ]
Hazi, Gabor [1 ]
Dezso, Zoltan [1 ]
Parko, Tamas [2 ]
Pos, Istvan [2 ]
Ignits, Miklos [2 ]
Homanyi, Laszlo [3 ]
机构
[1] Hungarian Acad Sci, Ctr Energy Res, POB 49, H-1525 Budapest 114, Hungary
[2] MVM Paks Nucl Power Plant Ltd, H-7031 Paks, Hungary
[3] KFKI Regtron Ltd, H-1121 Budapest, Hungary
来源
25TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2016) | 2016年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Reactivity Monitoring System and the Refuelling Neutron Monitoring System of Paks NPP are aged and need to be reconstructed. Since both systems are based on neutron flux measurements, the new system is to be served by the same detectors and measurement instrumentation. In order to provide data during refuelling, start-up and at full power, a full range system is required, i.e. the detectors and the associated instrumentation should cover the full range of neutron flux measurements from 0% to 100% of reactor power. Additionally, the new system is required to operate continuously, to maintain a measurement archive, and to provide data for the Process Computer and the VERONA core monitoring system. In order to cover the full neutron flux range, Photonis CFUL08 type fission chamber was chosen. The interface module will serve all three operation modes of the detector: pulse, Campbell (AC) and current (DC) modes. In order to obtain high reliability and dependability, the system will be built from independent and redundant components.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Investigation of Motor Faults in NPP using in Service Motor Monitoring System
    Mishra, Nishant
    Roy, Kallol
    Rautela, Pradeep
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [32] False alarm analysis of loose part monitoring system at tianwan NPP
    Zhou, Zhengping
    Ouyang, Qin
    Mao, Qiuhua
    Yuan, Shaobo
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (01): : 161 - 164
  • [33] Developing an electrical distribution monitoring system
    Univ of A Coruna
    IEEE Comput Appl Power, 1 (36-41):
  • [34] Developing a patient care monitoring system
    Grizenko, N
    Poinsier, B
    Mercier, C
    Perreault, M
    Latimer, E
    CANADIAN JOURNAL OF PSYCHIATRY-REVUE CANADIENNE DE PSYCHIATRIE, 2000, 45 (01): : 88 - 89
  • [35] Developing an electrical distribution monitoring system
    Roldan, MCSC
    AlonsoBetanzos, A
    AriasRodriques, JE
    IEEE COMPUTER APPLICATIONS IN POWER, 1997, 10 (01): : 36 - 41
  • [36] In situ gamma spectroscopy monitoring of the full system decontamination efficiency at the Loviisa NPP
    Tanner, V
    Kvarnstrom, R
    WATER CHEMISTRY OF NUCLEAR REACTOR SYSTEMS 7, VOL 1, 1996, : 330 - 334
  • [37] ATMOSPHERIC BOUNDARY LAYER MONITORING WITH THE SODAR/RASS SYSTEM ON THE BELARUSIAN NPP SITE
    Bryukhan, F. F.
    ATOMIC ENERGY, 2017, 122 (01) : 69 - 74
  • [38] Modification design and implementation of core cooling monitoring system in Daya Bay NPP
    Wang, Yuan
    Xiong, Guohua
    Hedongli Gongcheng/Nuclear Power Engineering, 2015, 36 (01): : 60 - 63
  • [39] Automated System for Monitoring the Radiation Situation at NPP and Environs: a Safety Security Tool
    Korotkov, A. S.
    Turlova, A. V.
    Kosov, A. D.
    Orekhov, A. A.
    ATOMIC ENERGY, 2018, 125 (01) : 39 - 44
  • [40] Atmospheric Boundary Layer Monitoring with the SODAR/RASS System on the Belarusian NPP Site
    F. F. Bryukhan’
    Atomic Energy, 2017, 122 : 69 - 74