Spectrum of m-mode echocardiographic abnormalities in 75 cats with systemic hypertension

被引:26
|
作者
Henik, RA [1 ]
Stepien, RL
Bortnowski, HB
机构
[1] Univ Wisconsin, Sch Vet Med, Dept Med Sci, Madison, WI 53706 USA
[2] Mobile Vet Diagnost, Madison, WI 53714 USA
关键词
D O I
10.5326/0400359
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A retrospective study was performed in 75 hypertensive cats to determine the spectrum and frequency of M-mode echocardiographic abnormalities. Results indicated that 21.3% of the cats had M-mode measurements within normal reference ranges. For cats with echocardiographic abnormalities, changes were variable. Thirty-nine percent of hypertensive cats had hypertrophy of the interventricular septum in diastole, and 41.3% had hypertrophy of the left ventricular (LV) posterior wall in diastole. One cat in five had a dilated left atrium, while fractional shortening and LV internal dimension in diastole were normal in 82.7% and 86.7% of the cats, respectively. The marked variability of echocardiographic findings in hypertensive cats made echocardiography an unreliable screening test for hypertension.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 50 条
  • [31] Echocardiographic Applications of M-Mode Ultrasonography in Anesthesiology and Critical Care
    Prada, Gabriel
    Vieillard-Baron, Antoine
    Martin, Archer K.
    Hernandez, Antonio
    Mookadam, Farouk
    Ramakrishna, Harish
    Diaz-Gomez, Jose L.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1559 - 1583
  • [32] M-MODE ECHOCARDIOGRAPHIC FINDINGS IN CHILDREN WITH IDIOPATHIC RESTRICTIVE CARDIOMYOPATHY
    MEHTA, AV
    FERRER, PL
    PICKOFF, AS
    SINGH, SS
    WOLFF, GS
    TAMER, DS
    GARCIA, OL
    GELBAND, H
    PEDIATRIC CARDIOLOGY, 1984, 5 (04) : 273 - 279
  • [33] NONPROLAPSING LEFT ATRIAL TUMOR - THE M-MODE ECHOCARDIOGRAPHIC DIAGNOSIS
    LEE, YC
    MAGRAM, MY
    CHEST, 1980, 78 (02) : 332 - 333
  • [34] VALIDATION OF M-MODE ECHOCARDIOGRAPHIC DIAMETER OF THE DILATED ASCENDING AORTA
    PYERITZ, RE
    BRINKER, JA
    FORTUIN, NJ
    WEISS, JL
    CLINICAL RESEARCH, 1980, 28 (02): : A204 - A204
  • [35] POSTOPERATIVE ABNORMALITIES OF INTER-VENTRICULAR SEPTAL MOTION - TWO-DIMENSIONAL AND M-MODE ECHOCARDIOGRAPHIC CORRELATIONS
    KERBER, RE
    LITCHFIELD, R
    AMERICAN HEART JOURNAL, 1982, 104 (02) : 263 - 268
  • [36] Two-dimensionally-guided M-mode and pulsed wave Doppler echocardiographic evaluation of the ventricles of apparently healthy cats
    Petric, Aleksandra Domanjko
    Rishniw, Mark
    Thomas, William P.
    JOURNAL OF VETERINARY CARDIOLOGY, 2012, 14 (03) : 423 - 430
  • [37] Echocardiographic and radiographic aortic remodeling in cats with confirmed systemic hypertension
    Holland, Merrilee
    Hofmeister, Erik H. H.
    Kupiec, Caitlin
    Hudson, Judith
    Fiske, Kaitlin
    VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (03) : 501 - 510
  • [38] Colour M-mode tissue Doppler imaging in healthy cats and cats with hypertrophic cardiomyopathy
    Koffas, H.
    Dukes-McEwan, J.
    Corcoran, B. M.
    Moran, C. M.
    French, A.
    Sboros, V.
    Simpson, K.
    Anderson, T.
    McDicken, W. N.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2008, 49 (07) : 330 - 338
  • [39] M-MODE ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF PULMONARY-HYPERTENSION
    AGATI, L
    PUDDU, PE
    FEDELE, F
    PENCO, M
    GIANNICO, S
    MODENA, MG
    BENASSI, A
    PASTORE, LR
    ARATA, L
    DAGIANTI, A
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1983, 76 (03): : 315 - 321
  • [40] HEMODYNAMICS OF HYPERTENSION IN PREGNANCY ASSESSED BY M-MODE ECHOCARDIOGRAPHY
    LARKIN, H
    GALLERY, EDM
    HUNYOR, SN
    GYORY, AZ
    BOYCE, ES
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1980, 7 (05) : 463 - 468