Measurement of apex angle of the prism using total internal reflection

被引:4
|
作者
Ghodgaonkar, AM [1 ]
Tewari, RD [1 ]
机构
[1] Univ Mumbai, Western Reg Instrumentat Ctr, Bombay 400098, Maharashtra, India
来源
OPTICS AND LASER TECHNOLOGY | 2004年 / 36卷 / 08期
关键词
D O I
10.1016/j.optlastec.2004.01.008
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Total internal reflection technique is examined critically for the measurement of apex angle of the prism. Recognition of the critical boundary completely specifies the apex angle 'A' of the prism by keeping constant the ratio of refractive index of sample fluid (n(1) = 1.4) to that of glass (n(2) = 1.7). Recording of observations in the laboratory is dependent upon whether the apex angle 'A' of prism is greater than or less than or equal to critical angle 'r(c)'. The minimum value of error function 'chi' in the proximity of Abbe angle explain the choice of Abbe type instruments and shown invariant by relating positive 'alpha(+)' and the negative angle of emergence 'alpha(-)'. Using ray-tracing technique, an expression for the length of the critical boundary 'l' is derived and is shown as a measure of the apex angle 'A' of the prism. The choice of the realistic grazing condition leads us to two turning points for which error function is minimal and yields appropriate option of the measurement of apex angle 'A' of the prism. It is further shown that the small error 'zeta' crept in the apex angle 'A' of the prism can lead to a significant error in the design of Pulfrich type instruments. Experimental measurements are in-line with the predictions made. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 50 条
  • [21] Pico-second optical switch using micromachined total internal reflection prism
    Li, J
    Zhang, XM
    Liu, AQ
    Tang, M
    [J]. Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 1179 - 1182
  • [22] Angle-invariant imaging using a total internal reflection virtual aperture
    Agurok, Ilya P.
    Ford, Joseph E.
    [J]. APPLIED OPTICS, 2016, 55 (20) : 5345 - 5352
  • [23] Total internal reflection without change of polarization using a right-angle prism with half-wavelength-thick optical interference coating
    Azzam, R. M. A.
    [J]. OPTICS LETTERS, 2009, 34 (03) : 371 - 373
  • [24] Optical Measurement of Contact Forces Using Frustrated Total Internal Reflection
    Sharp, James S.
    Poole, Stuart F.
    Kleiman, Benjamin W.
    [J]. PHYSICAL REVIEW APPLIED, 2018, 10 (03):
  • [25] A prism combination for near isotropic fluorescence excitation by total internal reflection
    Wakelin, S
    Bagshaw, CR
    [J]. JOURNAL OF MICROSCOPY, 2003, 209 (02) : 143 - 148
  • [26] Improved angle interferometer based on total internal reflection
    Zhou, WD
    Cai, LL
    [J]. APPLIED OPTICS, 1999, 38 (07) : 1179 - 1185
  • [27] Vacuum measurement using total-internal-reflection heterodyne interferometry
    Chiu, MH
    Lee, JY
    Su, DC
    Lee, KH
    [J]. PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1999, 23 (04): : 260 - 263
  • [28] Scanning angle total internal reflection Raman microspectroscopy
    Smith, Emily A.
    McKee, Kristopher
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [29] Fundamental investigation on the plane TIR(total internal reflection)prism resonator
    Chen, XY
    Wang, YZ
    Wang, L
    Gao, XR
    Zhao, G
    [J]. LASER RESONATORS IV, 2001, 4270 : 219 - 226
  • [30] Global solution of achromatic Total Internal Reflection prism in projection system
    Pan, Jui-Wen
    Li, Jhong-Syuan
    Wang, Chih-Ming
    [J]. OPTICS COMMUNICATIONS, 2018, 428 : 144 - 151